GEt Quote

ALab™ DL-SUB03 Multi-functional Horizontal Electrophoresis Tank

In stock
SKU# ALDLS30F

Product Detail

ALab™ DL-SUB03 Multi-functional Horizontal Electrophoresis Tank — a horizontal electrophoresis tank with two gel sizes (130×200mm and 130×150mm) for general and high-throughput electrophoresis, a blue light shielding clamshell design and an 800mL buffer volume.

ALab DL-SUB03 multi-functional horizontal electrophoresis tank with lid and electrode cables, gel trays and sample combs
ALab™ DL-SUB03 Multi-functional Horizontal Electrophoresis Tank — image shown for reference.

The DL-SUB03 is a multi-functional horizontal electrophoresis tank suitable for nucleic acid electrophoresis, separation and identification of DNA and determination of its molecular weight. It is made of polycarbonate high-strength transparent plastic by injection molding (no leakage, impact resistance); the professional shielding blue light clamshell design lets the open cover effectively dissipate heat, and the bottom level adjustment knob adjusts the level of the tank. The gel size is 130×200mm and 130×150mm, with 1.0mm sample combs of 14, 18 and 26 wells and a 1.5mm 18-well comb; the buffer volume is 800mL.

Why choose the DL-SUB03

Intended useSuitable for nucleic acid electrophoresis, separation and identification of DNA and determination of its molecular weight.
Tank bodyPolycarbonate high-strength transparent plastic injection molding, no leakage, impact resistance.
Blue light shieldProfessional shielding blue light clamshell design, open the cover can effectively dissipate heat.
Level adjustmentThe bottom level adjustment knob can adjust the level of the electrophoresis tank.
Two gel sizesTwo different gel sizes, meet the needs of general and high-throughput electrophoresis.
Gel box designThe front and back design of the gel box, can save space.
Background stripThe background strip at the bottom of the tray is more conducive to observing sample loading.
Platinum electrode99.99% high-purity platinum electrode, the best conductivity.
Gel size (W×L)
130×200mm, 130×150mm
Buffer volume
800mL
Gel sizes
2

Specifications General — DL-SUB03

ParameterSpecification
BrandALab™ by ACS Material
ModelDL-SUB03
SKU #ALDLS300
Product TypeMulti-functional horizontal electrophoresis tank
Gel size (W×L)130×200mm, 130×150mm
Sample comb1.0mm: 14, 18, 26 wells; 1.5mm: 18-well
Buffer volume800mL

Standard configuration DL-SUB03

NameUnitQuantity
Lid with cablesset1
Body tank with electrodesset1
Gel boxpc1
Large gel tray (130×200)pc1
Small gel tray (130×150)pc1
1.0mm thickness 14 wells combpc2
1.0mm thickness 18 wells combpc2
1.0mm thickness 26 wells combpc2
1.5mm thickness 18 wells combpc2

Where it fits

The DL-SUB03 is listed for nucleic acid electrophoresis, separation and identification of DNA and determination of its molecular weight. Two different gel sizes (130×200mm and 130×150mm) meet the needs of general and high-throughput electrophoresis; the front and back design of the gel box can save space, and the background strip at the bottom of the tray is more conducive to observing sample loading. The Standard configuration table above lists the supplied trays and combs with their quantities.

Frequently asked questions

What is the DL-SUB03?

A multi-functional horizontal electrophoresis tank suitable for nucleic acid electrophoresis, separation and identification of DNA and determination of its molecular weight.

Which gel sizes and buffer volume are listed?

Gel size (W×L): 130×200mm and 130×150mm; buffer volume: 800mL.

Which sample combs are listed?

Sample comb: 1.0mm 14, 18, 26 wells; 1.5mm 18-well. The standard configuration includes 2 pc each of the 1.0mm thickness 14, 18 and 26 wells combs and the 1.5mm thickness 18 wells comb.

What is in the standard configuration?

Lid with cables 1 set, body tank with electrodes 1 set, gel box 1 pc, large gel tray (130×200) 1 pc, small gel tray (130×150) 1 pc and the four comb types listed above (2 pc each).

How does the cover work?

Professional shielding blue light clamshell design; opening the cover can effectively dissipate heat. The bottom level adjustment knob can adjust the level of the electrophoresis tank.

What else is listed?

The front and back design of the gel box can save space; the background strip at the bottom of the tray is more conducive to observing sample loading; 99.99% high-purity platinum electrode, the best conductivity.

ALab™ DEP-300/DEP-600/DEP-300HC Electrophoresis Power Supplies — DEP-300, DEP-600 and DEP-300HC electrophoresis power supplies with an LCD touchscreen and four output sockets.
ALab™ DL-Mini01 Vertical Electrophoresis Tank (Double Plate) — vertical electrophoresis tank (double plate): two 8.3×7.3cm gels at the same time.
ALab™ DL-MINI04 Vertical Electrophoresis Tank — vertical electrophoresis tank: 1-4 gels, hand-cast gel 8.3×7.3cm or precast gel 8.6×6.8cm.
ALab™ DL-ZY02 Transfer Electrophoresis Tank — transfer electrophoresis tank: transfer area 110×90mm, two 83*73mm gels at the same time.
ALab™ DL-ZY03 Transfer Electrophoresis Tank — transfer electrophoresis tank: effective transfer area 110×90mm, two 83*73mm at the same time.
ALab™ DL-ZY04 Transfer Electrophoresis Tank — transfer electrophoresis tank: effective transfer area 110×90mm, four 83*73mm at the same time.
ALab™ DL-SUB01 Horizontal Electrophoresis Tank — horizontal electrophoresis tank: gel size 60×75mm, buffer volume 300mL.
ALab™ DL-SUB02 Multi-functional Horizontal Electrophoresis Tank — multi-functional horizontal electrophoresis tank: four gel sizes, buffer volume 700mL.
ALab™ is a trademark of ACS Material, LLC. Disclaimer: ACS Material, LLC believes the information on this page is accurate and represents the best and most current information available to us. Specifications reflect the current published data; final configurations are confirmed at quotation — always refer to the model datasheet for confirmed model-specific specifications, and follow your laboratory's safety procedures for horizontal electrophoresis tank operation. ACS Material makes no representations or warranties, express or implied, regarding suitability for any purpose, and will not be responsible for damages resulting from use of or reliance upon this information.