GEt Quote

ALab™ Hipette Mechanical Pipette

As low as $91.00 $0.00
In stock
SKU# ALHIPT00

Product Detail

ALab™ Hipette — a fully autoclavable manual adjustable colorful pipette in single-channel, 8-channel, 12-channel and 16-channel versions, with color coding, a volume lock design and a 4-digit display; the entire pipette can be autoclaved.

ALab Hipette adjustable pipettes in 8-channel, 12-channel and 16-channel versions with blue color-coded caps
ALab™ Hipette Mechanical Pipette — image shown for reference.

The HiPette is a fully autoclavable manual adjustable colorful pipette (8&12&16-channel; single-channel models are listed in the specification tables). The entire pipette is lightweight with a light press force; ejecting the tip requires minimal effort, and the press stroke is of moderate length. Different colored caps correspond to different volume ranges, a volume lock design prevents accidental changes in volume, and a 4-digit display gives high accuracy and clear volume readings. The entire pipette can be autoclaved and can also be disinfected with UV light, and it is easy to disassemble and maintain. The specification tables below list the volume range, increment, test volume, systematic error and random error of the single-channel (ten models), 8-channel, 12-channel and 16-channel pipettes.

Why choose the HiPette

Color CodingDifferent colored caps correspond to different volume ranges.
Ergonomic DesignThe entire pipette is lightweight with a light press force. Ejecting the tip requires minimal effort, and the press stroke is of moderate length. The comfortable finger rest reduces hand fatigue, while the handle is easy and comfortable to grip.
Volume Lock DesignPrevents accidental changes in volume.
4-Digit DisplayHigh accuracy and clear volume readings.
High-Temperature and High-Pressure SterilizationThe entire pipette can be autoclaved and can also be disinfected with UV light. It is easy to disassemble and maintain.
360° RotationCan freely rotate 360° in any direction.
Elastic Nozzle FunctionNo need for repeated tapping; a light touch can securely attach the pipette tips, providing good tightness and consistency for multi-channel pipetting and reducing the force required for ejection.
RepeatabilityStrong repeatability and consistency across 8 channels.
Single-channel
0.1–10000 μL
8 / 12-channel
0.5–300 μL
16-channel
1–100 μL
Sterilization
Autoclavable

Specifications General — Hipette

ParameterSpecification
BrandALab™ by ACS Material
ModelHipette
SKU #ALHIPT00
Product TypeFully Autoclavable Manual Adjustable Colorful Pipette (single-channel, 8-, 12- and 16-channel)
Single-channelTen models, 0.1–10000 μL
8-channelFive volume ranges, 0.5–300 μL
12-channelFive volume ranges, 0.5–300 μL
16-channelTwo volume ranges, 1–100 μL
SterilizationAutoclaving (high-temperature, high-pressure) or UV disinfection
Display4-digit display
Calibration referenceISO 8655-2

Volume range and accuracy single-channel · 8-channel · 12-channel · 16-channel

Single-channel Adjustable Volume Pipettes (10 models, covering 0.1µL~10mL)

Volume range (µL)Increment (µL)Test volume (µL)Systematic error (µL)Systematic error (%)Random error (µL)Random error (%)
0.1–2.50.0022.5
1.25
0.25
±0.04
±0.03
±0.03
±1.4
±2.5
±12.0
±0.02
±0.02
±0.02
±0.7
±1.5
±6.0
0.5–100.0110
5
1
±0.10
±0.08
±0.03
±1.0
±1.5
±2.5
±0.04
±0.04
±0.02
±0.4
±0.8
±1.8
2–200.0220
10
2
±0.20
±0.12
±0.10
±1.0
±1.2
±5.0
±0.06
±0.06
±0.03
±0.3
±0.6
±1.5
5–500.0550
25
5
±0.45
±0.35
±0.15
±0.9
±1.4
±3.0
±0.15
±0.20
±0.08
±0.3
±0.8
±1.6
10–1000.1100
50
10
±0.80
±0.50
±0.30
±0.8
±1.0
±3.0
±0.20
±0.15
±0.10
±0.2
±0.3
±1.0
20–2000.2200
100
20
±1.20
±1.00
±0.50
±0.6
±1.0
±2.5
±0.40
±0.30
±0.14
±0.2
±0.3
±0.7
30–3000.2300
150
30
±1.80
±1.50
±0.75
±0.6
±1.0
±2.5
±0.60
±0.45
±0.21
±0.2
±0.3
±0.7
100–100011000
500
100
±6.00
±5.00
±3.00
±0.6
±1.0
±3.0
±2.00
±1.00
±0.60
±0.2
±0.2
±0.6
500–500055000
2500
500
±30.00
±15.00
±12.00
±0.6
±0.6
±2.4
±10.00
±7.50
±3.00
±0.2
±0.3
±0.6
1000–100001010000
5000
1000
±60.00
±40.00
±30.00
±0.6
±0.8
±3.0
±20.00
±10.00
±6.00
±0.2
±0.2
±0.6

8-channel Adjustable Volume Pipettes

Volume range (µL)Increment (µL)Test volume (µL)Systematic error (µL)Systematic error (%)Random error (µL)Random error (%)
0.5–100.0110
5
1
±0.20
±0.20
±0.10
±2.0
±4.0
±10.0
±0.12
±0.125
±0.06
±1.2
±2.5
±6.0
5–500.0550
25
5
±0.60
±0.50
±0.25
±1.2
±2.0
±5.0
±0.30
±0.30
±0.20
±0.6
±1.2
±4.0
10–1000.1100
50
10
±1.00
±0.60
±0.40
±1.0
±1.2
±4.0
±0.50
±0.50
±0.25
±0.5
±1.0
±2.5
20–2000.2200
100
20
±2.00
±1.50
±0.80
±1.0
±1.5
±4.0
±1.00
±0.80
±0.40
±0.5
±0.8
±2.0
30–3000.2300
150
30
±3.00
±2.25
±1.20
±1.0
±1.5
±4.0
±1.50
±1.20
±0.60
±0.5
±0.8
±2.0

12-channel Adjustable Volume Pipettes

Volume range (µL)Increment (µL)Test volume (µL)Systematic error (µL)Systematic error (%)Random error (µL)Random error (%)
0.5–100.0110
5
1
±0.2
±0.2
±0.1
±2.0
±4.0
±10.0
±0.12
±0.125
±0.06
±1.2
±2.5
±6.0
5–500.0550
25
5
±0.6
±0.5
±0.25
±1.2
±2.0
±5.0
±0.3
±0.3
±0.2
±0.6
±1.2
±4.0
10–1000.1100
50
10
±1.0
±0.6
±0.4
±1.0
±1.2
±4.0
±0.5
±0.5
±0.25
±0.5
±1.0
±2.5
20–2000.2200
100
20
±2
±1.5
±0.8
±1.0
±1.5
±4.0
±1
±0.8
±0.4
±0.5
±0.8
±2.0
30–3000.2300
150
30
±3
±2.25
±1.2
±1.0
±1.5
±4.0
±1.5
±1.2
±0.6
±0.5
±0.8
±2.0

16-channel Adjustable Volume Pipettes

Volume range (µL)Increment (µL)Test volume (µL)Systematic error (µL)Systematic error (%)Random error (µL)Random error (%)
1–200.0120
10
2
±0.40
±0.40
±0.16
±2.0
±4.0
±8.0
±0.2
±0.2
±0.1
±1.0
±2.0
±5.0
5–1000.1100
50
10
±1.00
±0.60
±0.30
±1.0
±1.2
±3.0
±0.6
±0.4
±0.2
±0.6
±0.8
±2.0

User calibration should refer to the industrial standard ISO8655-2.

Order codes one SKU per configuration

ConfigurationSKU #
Single-channel · 0.1–2.5 μLALHIPT01
Single-channel · 0.5–10 μLALHIPT02
Single-channel · 2–20 μLALHIPT03
Single-channel · 5–50 μLALHIPT04
Single-channel · 10–100 μLALHIPT05
Single-channel · 20–200 μLALHIPT06
Single-channel · 30–300 μLALHIPT07
Single-channel · 100–1000 μLALHIPT08
Single-channel · 500–5000 μLALHIPT09
Single-channel · 1000–10000 μLALHIPT10
8-channel · 0.5–10 μLALHIPT11
8-channel · 5–50 μLALHIPT12
8-channel · 10–100 μLALHIPT13
8-channel · 20–200 μLALHIPT14
8-channel · 30–300 μLALHIPT15
12-channel · 0.5–10 μLALHIPT16
12-channel · 5–50 μLALHIPT17
12-channel · 10–100 μLALHIPT18
12-channel · 20–200 μLALHIPT19
12-channel · 30–300 μLALHIPT20
16-channel · 1–20 μLALHIPT21
16-channel · 5–100 μLALHIPT22
Set 1 · 0.5–10 μL + 10–100 μL + 100–1000 μL + Linear Stand + Cap opener + Hipette penALHIPT23
Set 2 · 2–20 μL + 20–200 μL + 100–1000 μL + Linear Stand + Cap opener + Hipette penALHIPT24
Set 3 · 100–1000 μL + 0.5–5 mL + 1–10 mL + Linear Stand + Cap opener + Hipette penALHIPT25

Parent SKU: ALHIPT00. Select the configuration in the order menu.

Online ordering is available for the configurations shown in the selector. For other listed configurations, contact us for pricing.

Package contents

Supplied with the instrumentQty
ALab™ Hipette pipette or pipette set, as selected1

For ALHIPT23–25, the supplied configuration is the selected Set 1–3 listed in Order codes. Package contents reflect the current published configuration; the itemized bill of materials is confirmed on the quotation.

Where it fits

The HiPette is lightweight with a light press force, minimal tip-ejection effort and a comfortable finger rest that reduces hand fatigue. Different colored caps correspond to different volume ranges and the volume lock design prevents accidental changes in volume. The entire pipette can be autoclaved and can also be disinfected with UV light, and the elastic nozzle function means no repeated tapping is needed: a light touch securely attaches the pipette tips, providing good tightness and consistency for multi-channel pipetting. Choose single-channel (0.1–2.5 to 1000–10000 µL), 8-channel or 12-channel (0.5–10 to 30–300 µL) or 16-channel (1–20 and 5–100 µL), or one of the three pipette sets, and the volume range that matches your volumes.

Frequently asked questions

Which channel configurations are available?

Single-channel (10 models, covering 0.1 µL to 10 mL), 8-channel and 12-channel (five ranges each, 0.5–10 to 30–300 µL) and 16-channel (1–20 and 5–100 µL) adjustable pipettes.

Can the HiPette be autoclaved?

Yes. The entire pipette can be autoclaved and can also be disinfected with UV light. It is easy to disassemble and maintain.

How are the volume ranges told apart?

By color coding: different colored caps correspond to different volume ranges.

How are accidental volume changes prevented?

The volume lock design prevents accidental changes in volume.

What is the elastic nozzle function?

No need for repeated tapping; a light touch can securely attach the pipette tips, providing good tightness and consistency for multi-channel pipetting and reducing the force required for ejection.

What do the pipette sets contain?

Set 1: 0.5–10 µL + 10–100 µL + 100–1000 µL + Linear Stand + Cap opener + Hipette pen. Set 2: 2–20 µL + 20–200 µL + 100–1000 µL + Linear Stand + Cap opener + Hipette pen. Set 3: 100–1000 µL + 0.5–5 mL + 1–10 mL + Linear Stand + Cap opener + Hipette pen.

What are the error limits of the 0.5–10 µL single-channel range?

Increment 0.01 µL. At 10, 5 and 1 µL test volume the systematic error is ±0.10, ±0.08 and ±0.03 µL (±1.0, ±1.5 and ±2.5 %) and the random error ±0.04, ±0.04 and ±0.02 µL (±0.4, ±0.8 and ±1.8 %).

Which SKU belongs to which configuration?

Each channel configuration and volume range, and each pipette set, has its own SKU; see the order codes table.

ALab™ MicroPette Plus Fully Autoclavable Mechanical Pipette — fully autoclavable mechanical pipette.
ALab™ Toppette Mechanical Pipette — mechanical pipette.
ALab™ Mi-Pette Mechanical Pipette — new generation colorful, fully autoclavable adjustable pipette, single-channel, 8-channel and 12-channel.
ALab™ HiPette-LTS Manual Adjustable Pipette — light feel manual adjustable color pipette.
ALab™ E-Pette Electronic Pipette — electronic pipette with a 2.1-inch OLED HD touchscreen.
ALab™ is a trademark of ACS Material, LLC. Disclaimer: ACS Material, LLC believes the information on this page is accurate and represents the best and most current information available to us. Specifications reflect the current published data; final configurations are confirmed at quotation — always refer to the model datasheet for confirmed model-specific specifications, and follow your laboratory's safety procedures for pipette operation. ACS Material makes no representations or warranties, express or implied, regarding suitability for any purpose, and will not be responsible for damages resulting from use of or reliance upon this information.