ALab™ MicroPette Plus — a fully autoclavable mechanical pipette in adjustable single-channel, fixed volume, 8-channel and 12-channel versions; it withstands 121 °C and 1 ATM and does not need to be pre-treated.

The MicroPette Plus pipette is fully autoclavable, being able to withstand temperatures of 121 °C and pressure of 1 ATM, and does not need to be pre-treated prior. Following the autoclave cycle, a 12 hour cooling and drying period ensures that the high performance of the MicroPette Plus is retained; it is recommended that the piston and rubber seals be greased after every 10 cycles of autoclaving. It is available in fixed volume and adjustable volume formats, with 8 and 12 channel pipette options, a streamlined shape design, easy calibration and maintenance, and a dispensing head that rotates for effortless pipetting convenience. The tip cones are spring loaded for easy cleaning and maintenance and made of a compound material that secures high sealing performance. The specification tables below list the volume range, increment, test volume, systematic error and random error of the single-channel adjustable, fixed volume, 8-channel and 12-channel pipettes.
Why choose the MicroPette Plus
Specifications General — MicroPette Plus
| Parameter | Specification |
|---|---|
| Brand | ALab™ by ACS Material |
| Model | MicroPette Plus |
| SKU # | ALMCPP00 |
| Product Type | Fully Autoclavable Mechanical Pipette |
| Single-channel adjustable | Twelve volume ranges, 0.1–10000 μL |
| Fixed volume | Twelve volumes, 5–5000 μL |
| 8-channel | Seven volume ranges, 0.5–1000 μL |
| 12-channel | Six volume ranges, 0.5–300 μL |
| Sterilization | Fully autoclavable: 121 °C, 1 ATM; no pre-treatment needed |
| After autoclaving | 12 hour cooling and drying period; grease the piston and rubber seals after every 10 autoclave cycles |
| Calibration reference | ISO 8655-2 |
Volume range and accuracy single-channel · fixed volume · 8-channel · 12-channel
Single-channel Adjustable Volume Pipettes
| Volume range (µL) | Increment (µL) | Test volume (µL) | Systematic error (µL) | Systematic error (%) | Random error (µL) | Random error (%) |
|---|---|---|---|---|---|---|
| 0.1–2.5 | 0.05 | 2.5 1.25 0.25 | ±0.0625 ±0.0375 ±0.03 | ±2.50 ±3.00 ±12.00 | ±0.05 ±0.0375 ±0.015 | ±2.00 ±3.00 ±6.00 |
| 0.5–10 | 0.1 | 10 5 1 | ±0.1 ±0.075 ±0.025 | ±1.00 ±1.50 ±2.50 | ±0.08 ±0.075 ±0.015 | ±0.80 ±1.50 ±1.50 |
| 2–20 | 0.5 | 20 10 2 | ±0.18 ±0.12 ±0.06 | ±0.90 ±1.20 ±3.00 | ±0.08 ±0.1 ±0.04 | ±0.40 ±1.00 ±2.00 |
| 5–50 | 0.5 | 50 25 5 | ±0.3 ±0.225 ±0.1 | ±0.60 ±0.90 ±2.00 | ±0.15 ±0.15 ±0.1 | ±0.30 ±0.60 ±2.00 |
| 10–100 | 1 | 100 50 10 | ±0.8 ±0.5 ±0.3 | ±0.80 ±1.00 ±3.00 | ±0.15 ±0.2 ±0.15 | ±0.15 ±0.40 ±1.50 |
| 20–200 | 1 | 200 100 20 | ±1.2 ±0.8 ±0.6 | ±0.60 ±0.80 ±3.00 | ±0.3 ±0.3 ±0.2 | ±0.15 ±0.30 ±1.00 |
| 50–200 | 1 | 200 100 50 | ±1.2 ±0.8 ±0.5 | ±0.60 ±0.80 ±1.00 | ±0.3 ±0.3 ±0.2 | ±0.15 ±0.30 ±0.40 |
| 100–1000 | 5 | 1000 500 100 | ±6 ±3.5 ±2 | ±0.60 ±0.70 ±2.00 | ±2 ±1.25 ±0.7 | ±0.20 ±0.25 ±0.70 |
| 200–1000 | 5 | 1000 500 200 | ±6 ±3.5 ±1.8 | ±0.60 ±0.70 ±0.90 | ±2 ±1.25 ±0.6 | ±0.20 ±0.25 ±0.30 |
| 500–5000 | 50 | 5000 2500 500 | ±25 ±15 ±3.5 | ±0.50 ±0.60 ±0.70 | ±7.5 ±7.5 ±1.5 | ±0.15 ±0.30 ±0.30 |
| 1000–5000 | 50 | 5000 2500 1000 | ±25 ±15 ±7 | ±0.50 ±0.60 ±0.70 | ±7.5 ±7.5 ±3 | ±0.15 ±0.30 ±0.30 |
| 1000–10000 | 100 | 10000 5000 1000 | ±60 ±60 ±30 | ±0.60 ±1.20 ±3.00 | ±20 ±15 ±6 | ±0.20 ±0.30 ±0.60 |
Fixed Volume Pipettes
| Volume range (µL) | Increment (µL) | Test volume (µL) | Systematic error (µL) | Systematic error (%) | Random error (µL) | Random error (%) |
|---|---|---|---|---|---|---|
| 5 | - | 5 | ±0.065 | ±1.3 | ±0.06 | ±1.2 |
| 10 | - | 10 | ±0.08 | ±0.8 | ±0.08 | ±0.8 |
| 20 | - | 20 | ±0.12 | ±0.6 | ±0.1 | ±0.5 |
| 25 | - | 25 | ±0.125 | ±0.5 | ±0.075 | ±0.3 |
| 50 | - | 50 | ±0.25 | ±0.5 | ±0.15 | ±0.3 |
| 100 | - | 100 | ±0.5 | ±0.5 | ±0.3 | ±0.3 |
| 200 | - | 200 | ±0.8 | ±0.4 | ±0.4 | ±0.2 |
| 250 | - | 250 | ±1.0 | ±0.4 | ±0.5 | ±0.2 |
| 500 | - | 500 | ±1.5 | ±0.3 | ±1.0 | ±0.2 |
| 1000 | - | 1000 | ±3.0 | ±0.3 | ±2.0 | ±0.2 |
| 2000 | - | 2000 | ±6.0 | ±0.3 | ±3.0 | ±0.15 |
| 5000 | - | 5000 | ±15 | ±0.3 | ±7.5 | ±0.15 |
8-channel Adjustable Volume Pipettes
| Volume range (µL) | Increment (µL) | Test volume (µL) | Systematic error (µL) | Systematic error (%) | Random error (µL) | Random error (%) |
|---|---|---|---|---|---|---|
| 0.5–10 | 0.1 | 10 5 1 | ±0.15 ±0.125 ±0.04 | ±1.50 ±2.50 ±4.00 | ±0.15 ±0.125 ±0.04 | ±1.50 ±2.50 ±4.00 |
| 5–50 | 0.5 | 50 25 5 | ±0.5 ±0.375 ±0.15 | ±1.00 ±1.50 ±3.00 | ±0.25 ±0.25 ±0.1 | ±0.50 ±1.00 ±2.00 |
| 10–100 | 1 | 100 50 10 | ±0.8 ±0.5 ±0.3 | ±0.80 ±1.00 ±3.00 | ±0.3 ±0.4 ±0.2 | ±0.30 ±0.80 ±2.00 |
| 20–200* | 0.1 | 200 100 20 | ±1.4 ±1.0 ±0.6 | ±0.70 ±1.00 ±3.00 | ±0.5 ±0.5 ±0.32 | ±0.25 ±0.50 ±1.60 |
| 30–300* | 0.2 | 300 150 30 | ±2.1 ±1.5 ±0.9 | ±0.70 ±1.00 ±3.00 | ±0.75 ±0.75 ±0.48 | ±0.25 ±0.5 ±1.60 |
| 50–300 | 5 | 300 150 50 | ±2.1 ±1.5 ±0.75 | ±0.70 ±1.00 ±1.50 | ±0.75 ±0.75 ±0.4 | ±0.25 ±0.50 ±0.80 |
| 100–1000 | 10 | 1000 500 100 | ±10 ±10 ±5 | ±1.00 ±2.00 ±5.00 | ±3 ±2.5 ±1 | ±0.30 ±0.50 ±1.00 |
12-channel Adjustable Volume Pipettes
| Volume range (µL) | Increment (µL) | Test volume (µL) | Systematic error (µL) | Systematic error (%) | Random error (µL) | Random error (%) |
|---|---|---|---|---|---|---|
| 0.5–10 | 0.1 | 10 5 1 | ±0.15 ±0.125 ±0.04 | ±1.50 ±2.50 ±4.00 | ±0.15 ±0.125 ±0.04 | ±1.50 ±2.50 ±4.00 |
| 5–50 | 0.5 | 50 25 5 | ±0.5 ±0.375 ±0.15 | ±1.00 ±1.50 ±3.00 | ±0.25 ±0.25 ±0.1 | ±0.50 ±1.00 ±2.00 |
| 10–100 | 0.1 | 200 100 20 | ±1.4 ±1.0 ±0.6 | ±0.70 ±1.00 ±3.00 | ±0.5 ±0.5 ±0.32 | ±0.30 ±0.80 ±2.00 |
| 20–200* | 0.2 | 300 150 30 | ±2.1 ±1.5 ±0.9 | ±0.70 ±1.00 ±3.00 | ±0.75 ±0.75 ±0.48 | ±0.25 ±0.50 ±1.60 |
| 30–300* | 1 | 100 50 10 | ±0.8 ±0.5 ±0.3 | ±0.80 ±1.00 ±3.00 | ±0.3 ±0.4 ±0.2 | ±0.30 ±0.80 ±2.00 |
| 50–300 | 5 | 300 150 50 | ±2.1 ±1.5 ±0.75 | ±0.70 ±1.00 ±1.50 | ±0.75 ±0.75 ±0.4 | ±0.25 ±0.50 ±0.80 |
User calibration should refer to the industrial standard ISO8655-2.
* specifications are used as guidelines and the user calibration should refer to the industrial standard ISO 8655
Order codes one SKU per configuration
| Configuration | SKU # |
|---|---|
| Single-channel adjustable · 0.1–2.5 μL | ALMCPP01 |
| Single-channel adjustable · 0.5–10 μL | ALMCPP02 |
| Single-channel adjustable · 2–20 μL | ALMCPP03 |
| Single-channel adjustable · 5–50 μL | ALMCPP04 |
| Single-channel adjustable · 10–100 μL | ALMCPP05 |
| Single-channel adjustable · 20–200 μL | ALMCPP06 |
| Single-channel adjustable · 50–200 μL | ALMCPP07 |
| Single-channel adjustable · 100–1000 μL | ALMCPP08 |
| Single-channel adjustable · 200–1000 μL | ALMCPP09 |
| Single-channel adjustable · 500–5000 μL | ALMCPP10 |
| Single-channel adjustable · 1000–5000 μL | ALMCPP11 |
| Single-channel adjustable · 1000–10000 μL | ALMCPP12 |
| Single-channel fixed volume · 5 μL | ALMCPP13 |
| Single-channel fixed volume · 10 μL | ALMCPP14 |
| Single-channel fixed volume · 20 μL | ALMCPP15 |
| Single-channel fixed volume · 25 μL | ALMCPP16 |
| Single-channel fixed volume · 50 μL | ALMCPP17 |
| Single-channel fixed volume · 100 μL | ALMCPP18 |
| Single-channel fixed volume · 200 μL | ALMCPP19 |
| Single-channel fixed volume · 250 μL | ALMCPP20 |
| Single-channel fixed volume · 500 μL | ALMCPP21 |
| Single-channel fixed volume · 1000 μL | ALMCPP22 |
| Single-channel fixed volume · 2000 μL | ALMCPP23 |
| Single-channel fixed volume · 5000 μL | ALMCPP24 |
| 8-channel adjustable · 0.5–10 μL | ALMCPP25 |
| 8-channel adjustable · 5–50 μL | ALMCPP26 |
| 8-channel adjustable · 10–100 μL | ALMCPP27 |
| 8-channel adjustable · 20–200 μL | ALMCPP28 |
| 8-channel adjustable · 30–300 μL | ALMCPP29 |
| 8-channel adjustable · 50–300 μL | ALMCPP30 |
| 8-channel adjustable · 100–1000 μL | ALMCPP31 |
| 12-channel adjustable · 0.5–10 μL | ALMCPP32 |
| 12-channel adjustable · 5–50 μL | ALMCPP33 |
| 12-channel adjustable · 10–100 μL | ALMCPP34 |
| 12-channel adjustable · 20–200 μL | ALMCPP35 |
| 12-channel adjustable · 30–300 μL | ALMCPP36 |
| 12-channel adjustable · 50–300 μL | ALMCPP37 |
Parent SKU: ALMCPP00. Select the configuration in the order menu.
Package contents
| Supplied with the instrument | Qty |
|---|---|
| ALab™ MicroPette Plus (configuration and volume range as selected) | 1 |
Package contents reflect the current published configuration; the itemized bill of materials is confirmed on the quotation.
Where it fits
Frequently asked questions
Which configurations are available?
Adjustable single-channel (twelve ranges, 0.1–2.5 to 1000–10000 µL), fixed volume (5 to 5000 µL), 8-channel adjustable (0.5–10 to 100–1000 µL) and 12-channel adjustable (0.5–10 to 50–300 µL) pipettes.
Can the MicroPette Plus be autoclaved?
Yes. It is fully autoclavable, being able to withstand temperatures of 121 °C and pressure of 1 ATM, and does not need to be pre-treated prior.
What should I do after autoclaving?
Allow a 12 hour cooling and drying period, which ensures that the high performance of the MicroPette Plus is retained. It is recommended that the piston and rubber seals be greased after every 10 cycles of autoclaving.
How are the tip cones designed?
The tip cones are spring loaded for easy cleaning and maintenance, and the compound material-made tip cone secures high sealing performance. Piston and tip cone are assembled individually.
Does the dispensing head rotate?
Yes. The dispensing head rotates for effortless pipetting convenience.
What are the error limits of the 0.5–10 µL single-channel range?
Increment 0.1 µL. At 10, 5 and 1 µL test volume the systematic error is ±0.1, ±0.075 and ±0.025 µL (±1.00, ±1.50 and ±2.50 %) and the random error ±0.08, ±0.075 and ±0.015 µL (±0.80, ±1.50 and ±1.50 %).
Which SKU belongs to which configuration?
Each channel configuration, fixed volume and volume range has its own SKU; see the order codes table.