GEt Quote

ALab™ Mini TopPette Pipette

In stock
SKU# ALMTPP00

Product Detail

ALab™ Mini TopPette Pipette — a compact pipette about 13 cm in length with a dual stop design, accuracy compliant with ISO 8655, a tip ejector and color-coded plunger caps by volume, available in six volumes: 5, 10, 50, 100, 200 and 300 µL.

ALab Mini TopPette pipettes in six volumes with color-coded plunger caps
ALab™ Mini TopPette Pipette — image shown for reference.

The Mini TopPette Pipette combines a dual stop design for precise aspiration and dispensing with a tip ejector for one-handed operation and easy tip disposal. Its plunger caps are color-coded by volume, which offers intuitive identification of the different volume specifications and reduces handling errors, and at about 13 cm in length it combines a comfortable grip with efficient operation. The specification table below lists the systematic and random error at the measured volume of each of the six volumes.

Why choose the Mini TopPette Pipette

Dual Stop DesignEnables precise aspiration and dispensing, meeting diverse experimental needs.
Accuracy Compliant with ISO 8655Ensures reliability and repeatability, enhancing the accuracy of experimental data.
Equipped with Tip EjectorAllows one-handed operation for easy tip disposal, improving lab efficiency.
Color-Coded Plunger Caps by VolumeOffers intuitive identification of different volume specifications, reducing handling errors.
Compact and delicateAbout 13 cm in length, combining comfortable grip with efficient operation.
Volumes
5–300 μL
Stop design
Dual stop
Length
About 13 cm

Specifications General — Mini TopPette

ParameterSpecification
BrandALab™ by ACS Material
ModelMini TopPette
SKU #ALMTPP00
Product TypePipette
VolumesSix volumes: 5, 10, 50, 100, 200 and 300 μL
Stop designDual stop design
AccuracyAccuracy compliant with ISO 8655
Tip ejectorEquipped with tip ejector
Plunger capsColor-coded by volume
LengthAbout 13 cm

Volume range and accuracy volume range · measured volume · systematic and random error

Volume range (µL)Measured volume (µL)Systematic error (µL)Systematic error (%)Random error (µL)Random error (%)
55±0.125±2.5±0.075±1.5
1010±0.12±1.2±0.08±0.8
5050±0.5±1.0±0.25±0.5
100100±0.8±0.8±0.3±0.3
200200±1.6±0.8± 0.6±0.3
300300±2.4±0.8±0.9±0.3

* For user calibration, please refer to international standard ISO 8655-2.

Order codes one SKU per configuration

VolumeSKU #
5 μLALMTPP01
10 μLALMTPP02
50 μLALMTPP03
100 μLALMTPP04
200 μLALMTPP05
300 μLALMTPP06

Parent SKU: ALMTPP00. Select the configuration in the order menu.

Package contents

Supplied with the instrumentQty
ALab™ Mini TopPette Pipette (volume as selected)1

Package contents reflect the current published configuration; the itemized bill of materials is confirmed on the quotation.

Where it fits

The Mini TopPette Pipette is a compact pipette with a dual stop design for precise aspiration and dispensing, meeting diverse experimental needs. The tip ejector allows one-handed operation and easy tip disposal, improving lab efficiency, and the color-coded plunger caps offer intuitive identification of the different volume specifications, reducing handling errors. Choose the volume that matches your work: 5, 10, 50, 100, 200 or 300 µL.

Frequently asked questions

Which volumes does the Mini TopPette Pipette cover?

Six volumes: 5, 10, 50, 100, 200 and 300 µL. The measured volume equals the volume range in the specification table; each volume has its own SKU in the order codes table.

What is the dual stop design?

The dual stop design enables precise aspiration and dispensing, meeting diverse experimental needs.

Does it comply with ISO 8655?

The accuracy is stated as compliant with ISO 8655, which ensures reliability and repeatability and enhances the accuracy of experimental data. For user calibration, please refer to international standard ISO 8655-2.

How are tips removed?

The pipette is equipped with a tip ejector that allows one-handed operation for easy tip disposal, improving lab efficiency.

How can I tell the volumes apart?

The plunger caps are color-coded by volume, which offers intuitive identification of different volume specifications and reduces handling errors.

How big is the Mini TopPette?

About 13 cm in length, combining comfortable grip with efficient operation.

What are the error limits of the 5 µL volume?

At a measured volume of 5 µL the systematic error is ±0.125 µL (±2.5%) and the random error is ±0.075 µL (±1.5%).

ALab™ Toppette Mechanical Pipette — mechanical pipette.
ALab™ Mi-Pette Mechanical Pipette — adjustable pipette, single-channel, 8-channel and 12-channel.
ALab™ Mini Pipette — Mini Pipette.
ALab™ E-Pette Electronic Pipette — electronic pipette with a 2.1-inch OLED HD touchscreen.
ALab™ dPette & dPette+ Electronic Pipettes — dPette+ multi-functional electronic pipette and dPette simple electronic pipette.
ALab™ is a trademark of ACS Material, LLC. Disclaimer: ACS Material, LLC believes the information on this page is accurate and represents the best and most current information available to us. Specifications reflect the current published data; final configurations are confirmed at quotation — always refer to the model datasheet for confirmed model-specific specifications, and follow your laboratory's safety procedures for pipette operation. ACS Material makes no representations or warranties, express or implied, regarding suitability for any purpose, and will not be responsible for damages resulting from use of or reliance upon this information.