GEt Quote

Levon™ SD300 Slot-Die Coater (300 × 300 mm substrate)

In stock
SKU# LVSD300F

Product Detail

Levon™ SD300 Slot-Die Coater (300 × 300 mm substrate) is a slot-die coater with a compatible substrate area of 300 × 300 mm, a 360 × 360 mm coating platform and integrated injection-pump control with a capacity-control range of 0–10 mL.

Levon SD300 slot-die coater with a gantry-mounted coating head over a black coating platform and a side-mounted touchscreen
Levon™ SD300 Slot-Die Coater (300 × 300 mm substrate) — image shown for reference.

The SD300 has auto tool alignment, a granite platform and dual vertical-axis servo motors for automatic adjustment. Z-axis speed control is 0.001–20 mm/s with a stroke of 0–50 mm and a synchronous repeatability of ±0.002 mm; Y-axis speed control is 0.002–50 mm/s with a stroke of 0–450 mm; the positioning accuracy of both axes is 0.001 mm.

The SD300 provides integrated control for an injection (syringe) pump, with capacity control of 0–10 mL and output speed control of 0–1000 µL/s. Contact detection has a resolution of ±1 µm and an accuracy of 1 µm. The platform has a vacuum adsorption function with a standard hole size of 2 mm (minimum 1 mm, customizable), and the compatible substrate thickness is 0.05–10 mm.

The SD300 has an equipment power of 800 W and a power input of AC 200–240 V, single-phase (for the 220 V model); the gas interface is a rear-panel outlet with a 6 mm outer diameter. The unit measures 1000 × 700 × 680 mm (W × D × H), requires installation dimensions of 1100 × 800 × 780 mm (W × D × H), weighs 150 kg and is shipped in carton packaging.

Why choose the SD300

Auto tool alignmentAuto tool alignment of the coating tool head.
Granite platformGranite platform with a coating platform area of 360 × 360 mm.
Dual vertical-axis servo motorsDual vertical-axis servo motors for automatic adjustment; Z-axis positioning accuracy of 0.001 mm.
Integrated injection-pump controlIntegrated injection-pump control: 0–10 mL capacity control and 0–1000 µL/s output speed control.
Contact detectionContact detection resolution of ±1 µm and contact detection accuracy of 1 µm.
Vacuum adsorptionVacuum adsorption function; standard hole size 2 mm (minimum 1 mm, customizable).
Substrate area
300 × 300 mm
Substrate thickness
0.05–10 mm
Y-axis stroke
0–450 mm
Positioning accuracy
0.001 mm
Weight
150 kg

Specifications General — SD300

ParameterSpecification
BrandLevon™ by ACS Material
ModelSD300
SKU #LVSD3000
Product TypeSlot-die coater
Compatible substrate area300 × 300 mm
Compatible substrate thickness0.05–10 mm
Coating platform area360 × 360 mm
PlatformGranite platform with vacuum adsorption function
Vacuum adsorption holesStandard hole size 2 mm (minimum 1 mm, customizable)
Tool alignmentAuto tool alignment
Vertical-axis driveDual vertical-axis servo motors, automatic adjustment
Equipment power800 W
Power inputAC 200–240 V, single-phase (for the 220 V model)
Gas interfaceRear-panel outlet, 6 mm outer diameter
Dimensions [W × D × H]1000 × 700 × 680 mm
Installation dimensions1100 × 800 × 780 mm (W × D × H)
Weight150 kg
PackingCarton packaging
Warranty1-year product warranty

Motion, dispensing and contact detection SD300

ParameterSpecification
Z-axis speed control0.001–20 mm/s
Z-axis positioning accuracy0.001 mm
Z-axis stroke control0–50 mm
Z-axis synchronous repeatability±0.002 mm
Y-axis speed control0.002–50 mm/s
Y-axis positioning accuracy0.001 mm
Y-axis stroke control0–450 mm
Injection pump capacity control0–10 mL
Injection pump output speed control0–1000 µL/s
Contact detection resolution±1 µm
Contact detection accuracy1 µm

Package contents

Supplied with the instrumentQty
Levon™ SD300 main unit1

External utilities, where required, are supplied by the user. Package contents reflect the current published configuration; the itemized bill of materials is confirmed on the quotation.

Where it fits

For laboratory slot-die coating on substrates with a compatible substrate area of 300 × 300 mm and a thickness of 0.05–10 mm, on a 360 × 360 mm coating platform. For a compatible substrate area of 200 × 200 mm in a smaller unit (820 × 600 × 680 mm), see the SD200.

Frequently asked questions

What substrate sizes are supported?

The compatible substrate area is 300 × 300 mm and the compatible substrate thickness is 0.05–10 mm; the coating platform area is 360 × 360 mm.

What are the axis specifications?

Z-axis: speed control 0.001–20 mm/s, positioning accuracy 0.001 mm, stroke 0–50 mm, synchronous repeatability ±0.002 mm. Y-axis: speed control 0.002–50 mm/s, positioning accuracy 0.001 mm, stroke 0–450 mm.

What injection-pump control ranges are specified?

Capacity control of 0–10 mL and output speed control of 0–1000 µL/s.

How is the substrate held?

The platform has a vacuum adsorption function with a standard hole size of 2 mm (minimum 1 mm, customizable).

What utilities are required?

Power input AC 200–240 V, single-phase (for the 220 V model), equipment power 800 W; the gas interface is a rear-panel outlet with a 6 mm outer diameter.

How large and heavy is the unit?

1000 × 700 × 680 mm (W × D × H), installation dimensions 1100 × 800 × 780 mm, and 150 kg; it is shipped in carton packaging.

Levon™ SD200 Slot-Die Coater (200 × 200 mm substrate) — slot-die coater for a 200 × 200 mm compatible substrate area, 260 × 260 mm coating platform, integrated injection-pump control.
Levon™ PF400 Film Applicator — film applicator, 1–300 mm/s, 420 mm maximum stroke, 540 × 345 mm vacuum panel, PF400 and heated PF400-H.
Levon™ UC200-SE Heated UV Ozone Cleaner — heated UV cleaner, 300 W lamp, 185 nm + 254 nm, hot plate RT to 200°C.
Levon™ is a trademark of ACS Material, LLC. Disclaimer: ACS Material, LLC believes the information on this page is accurate and represents the best and most current information available to us. Specifications reflect the current published data; final configurations are confirmed at quotation — always refer to the model datasheet for confirmed model-specific specifications, operate the instrument within its rated power, temperature and gas-supply limits, and follow your laboratory’s safety procedures for UV light sources, heated surfaces, moving parts, vacuum and electrical equipment. ACS Material makes no representations or warranties, express or implied, regarding suitability for any purpose, and will not be responsible for damages resulting from use of or reliance upon this information.