ALab™ Accurate 96 Real-Time PCR System
Product Detail
ALab™ Accurate 96 Real-Time PCR System — a 96-well real-time PCR system with Peltier thermal cycling at a max. heating/cooling rate of 6.0°C/s, MPPC detection with time-resolved signal separation and 4 or 6 fluorescent channels.

As a necessary choice for quantitative analysis of molecular biology, the real-time PCR system has been widely used in various fields such as scientific research, clinical detection and diagnosis, quality and safety testing, and forensic applications. The Accurate 96 takes 0.1ml PCR tubes×96, an 8×12 PCR plate or a 96 well plate ×1 (reaction volume 10-50 µl), uses Peltier thermal cycle technology with a max. heating/cooling rate of 6.0°C/s and detects with an MPPC and time-resolved signal separating technology. It is configured with 4 or 6 fluorescent channels; Cy3 is supported by the 6-channel configuration only. The photo shows one Accurate 96 unit and is not specific to either configuration.
Why choose the Accurate 96
Specifications General — Accurate 96
| Parameter | Specification |
|---|---|
| Brand | ALab™ by ACS Material |
| Model | Accurate 96 |
| SKU # | ALAQ9600 |
| Product Type | Real-time PCR system |
| Thermal cycle technology | Peltier |
| Detection device | MPPC |
| Detection mode | Time-resolved signal separating technology |
| Fluorescent channels | 4/6 channels |
Specifications by model Accurate 96 4-channel · 6-channel
| Parameter | 4-channel | 6-channel |
|---|---|---|
| Sample capacity | 0.1ml PCR tubes×96, 8×12 PCR plate or 96 well plate ×1 | 0.1ml PCR tubes×96, 8×12 PCR plate or 96 well plate ×1 |
| Reaction volume | 10-50 µl | 10-50 µl |
| Thermal cycle technology | Peltier | Peltier |
| Max. heating/cooling rate | 6.0°C/s | 6.0°C/s |
| Heating temperature range [°C] | 4–100 | 4–100 |
| Temperature accuracy [°C] | ±0.2 | ±0.2 |
| Temperature uniformity | ±0.2°C @60°C, ±0.2°C @95°C | ±0.2°C @60°C, ±0.2°C @95°C |
| Temperature gradient setting range [°C] | 30–100 | 30–100 |
| Temperature gradient difference setting range [°C] | 1–36 | 1–36 |
| Excitation light source | 5/6 monochrome high efficiency LEDs | 5/6 monochrome high efficiency LEDs |
| Detection device | MPPC | MPPC |
| Detection mode | Time-resolved signal separating technology | Time-resolved signal separating technology |
| Excitation/detection wavelength range | 455-650nm/510-715nm | 455-650nm/510-715nm |
| Fluorescent channels | 4 channels | 6 channels |
| Supported dye | FAM/SYBR Green, VIC/HEX, ROX, Cy5 | FAM/SYBR Green, VIC/HEX, ROX, Cy5, Cy3 |
| Sensitivity | Single copy gene | Single copy gene |
| Resolution | 1.33 folds copy number difference can be distinguished in single-plex qPCR | 1.33 folds copy number difference can be distinguished in single-plex qPCR |
| Dynamic range | 10 orders of magnitude copies | 10 orders of magnitude copies |
Order codes one SKU per configuration
| Model | SKU # |
|---|---|
| Accurate 96, 4-channel fluorescence detection | ALAQ9601 |
| Accurate 96, 6-channel fluorescence detection | ALAQ9602 |
Parent SKU: ALAQ9600. Select the configuration in the order menu.
Where it fits
Frequently asked questions
Which configurations are available?
The Accurate 96 is offered with 4 or 6 fluorescent channels; select the configuration in the order menu. The specification table lists both side by side.
Which dyes are supported?
FAM/SYBR Green, VIC/HEX, ROX and Cy5; Cy3 is supported by the 6-channel configuration only.
Is ROX correction required?
No. The Accurate 96 effectively reduces multi-color crosstalk and edge effect, and no ROX correction is required, reducing sample and reagent use.
Which tubes and plates can be used?
0.1ml PCR tubes×96, an 8×12 PCR plate or a 96 well plate ×1; reaction volume 10-50 µl.
What temperature performance is published?
Heating temperature range 4–100°C, temperature accuracy ±0.2°C, temperature uniformity ±0.2°C @60°C and ±0.2°C @95°C, a max. heating/cooling rate of 6.0°C/s, a temperature gradient setting range of 30–100°C and a gradient difference setting range of 1–36°C.
What sensitivity and dynamic range are published?
Sensitivity: single copy gene. Resolution: a 1.33 folds copy number difference can be distinguished in single-plex qPCR. Dynamic range: 10 orders of magnitude copies.