ALab™ MNE-96-03 Fully Automated Nucleic Acid Extraction System

In stock
SKU# ALMN960F

Product Detail

ALab™ MNE-96-03 Fully Automated Nucleic Acid Extraction System — an automated nucleic acid extraction and purification system for magnetic bead-based reagents: 1-96 samples (selectable), 96 samples extracted in 13 minutes, UV lamp sterilization and an 8-inch touch screen.

ALab MNE-96-03 fully automated nucleic acid extraction system with its front door and touch screen
ALab™ MNE-96-03 Fully Automated Nucleic Acid Extraction System — image shown for reference.

The MNE-96-03 fully automated nucleic acid extraction and purification system, used in conjunction with magnetic bead-based nucleic acid extraction reagents, performs automated extraction and purification of nucleic acids from various sample types. It is simple and fast to operate, making it an important choice for medium-to-high throughput sample processing, and it meets the application needs of various scenarios including clinical settings, disease control, scientific research, and forensics. The sample throughput is 1-96 samples (selectable), the processing volume is 50µL-1000µL and 96 samples are extracted in 13 minutes.

Why choose the MNE-96-03

Flexible and rapid1-96 samples processed in 13 minutes.
High extraction efficiencyMagnetic bead recovery rate ≥ 99%.
High biosafetyEnclosed process management and a built-in UV sterilization device effectively prevent contamination.
Easy operationIntelligent 8-inch touch screen display for easy operation, reducing dependency on specialized skills and manual workload.
Strong compatibilityWidely compatible with various magnetic bead-based nucleic acid purification and extraction kits available on the market.
Mixing and agitationAdjustable multi-mode and multi-level oscillation mixing.
Error alertSupports audible alarm and red light indicator.
Sample throughput
1-96 samples
Processing volume
50µL-1000µL
96 samples extracted in
13 minutes

Specifications General — MNE-96-03

ParameterSpecification
BrandALab™ by ACS Material
ModelMNE-96-03
SKU #ALMN9600
Product TypeFully automated nucleic acid extraction system
Sample throughput1-96 samples (selectable)
Processing volume50µL-1000µL
Processing speed96 samples extracted in 13 minutes
Contamination controlUV lamp sterilization
Mixing and agitationAdjustable multi-mode and multi-level oscillation mixing
Error alertSupports audible alarm and red light indicator
Operating voltage/powerAC 100V-240V; 50/60 Hz; 450W
Dimensions (L×W×H)660*400*470mm ±10mm
WeightGross weight 35kg; net weight 25kg
Software nameFully Automated Nucleic Acid Extraction and Purification Software

Where it fits

The MNE-96-03 is used with magnetic bead-based nucleic acid extraction reagents for medium-to-high throughput sample processing. Typical application fields: disease control centers, clinical disease diagnosis, emergency quarantine (mobile cabin laboratories, mobile detection vehicles), scientific research institutes, forensic identification, environmental microorganism detection and food safety testing.

Frequently asked questions

How many samples can be processed and how fast?

1-96 samples (selectable); 96 samples are extracted in 13 minutes.

Which reagents can be used?

It is used in conjunction with magnetic bead-based nucleic acid extraction reagents and is widely compatible with various magnetic bead-based nucleic acid purification and extraction kits available on the market. The magnetic bead recovery rate is ≥ 99%.

What processing volume is supported?

50µL-1000µL.

How is contamination controlled?

Enclosed process management and a built-in UV sterilization device (UV lamp sterilization) effectively prevent contamination.

How is it operated?

With an intelligent 8-inch touch screen display and the Fully Automated Nucleic Acid Extraction and Purification Software. Mixing and agitation are adjustable (multi-mode and multi-level oscillation mixing), and errors are signalled by an audible alarm and a red light indicator.

What are the power, size and weight?

AC 100V-240V; 50/60 Hz; 450W. Dimensions 660*400*470mm ±10mm (L×W×H). Gross weight 35kg; net weight 25kg.

ALab™ Accurate 96 Real-Time PCR System — real-time PCR system: 96 wells, 4 or 6 fluorescence channels.
ALab™ Accurate 16-T Real-Time Fluorescence Quantitative PCR System — compact real-time fluorescence quantitative PCR system: 16 wells, 2 or 4 fluorescence channels.
ALab™ TC1000-G-Pro & TC1000-S+ Gene Amplification Instruments — TC1000-G-Pro and TC1000-S+ gene amplification instruments with a 7-inch LCD touch panel.
ALab™ TC2000-G1/G2/G3 Thermal Cycler Gradient — single-, dual- and three-channel thermal cyclers with a 10.1-inch touch screen.
ALab™ is a trademark of ACS Material, LLC. Disclaimer: ACS Material, LLC believes the information on this page is accurate and represents the best and most current information available to us. Specifications reflect the current published data; final configurations are confirmed at quotation — always refer to the model datasheet for confirmed model-specific specifications, and follow your laboratory's safety procedures for nucleic acid extraction system operation. ACS Material makes no representations or warranties, express or implied, regarding suitability for any purpose, and will not be responsible for damages resulting from use of or reliance upon this information.