GEt Quote

ALab™ TC1000-G-Pro & TC1000-S+ Gene Amplification Instruments

In stock
SKU# ALTC1000

Product Detail

ALab™ TC1000-G-Pro & TC1000-S+ Gene Amplification Instruments — Peltier thermal cyclers with a 7-inch LCD touch panel, a 1×96 sample block, a 0–105 °C module range and a maximum rate of temperature change of 5 °C/Sec; the TC1000-G-Pro adds a gradient setting range of 30–105 °C.

ALab TC1000 series thermal cycler with the hot lid open over the 96-well sample block and a 7-inch touch panel (one photo for both models)
ALab™ TC1000-G-Pro & TC1000-S+ Gene Amplification Instruments — image shown for reference.

Elegant in design, precise and accurate, with high repeatability of results, the TC1000 series is specially designed for PCR optimization. It is equipped with advanced temperature control technology, high-performance and long-lasting Peltier refrigeration and heating, and edge temperature compensation technology, with excellent temperature uniformity performance. The TC1000-S+ and TC1000-G-Pro gene amplification instruments are basic instruments in molecular laboratories, widely used in gene detection, molecular cloning, gene expression, mutagenesis and other fields, involving drug discovery, agriculture, food industry and other fields. The TC1000-G-Pro is the gradient model (gradient setting range 30–105 °C, span 1–42 °C); the TC1000-S+ has the same block, display, interfaces and power. The photo shows one TC1000 unit and is not specific to either model; the specification table below lists both.

Why choose the TC1000 series

New UI and Color Touch PanelA brand new UI user interface with simple and easy-to-use graphical menus and a color touch panel, making it easier for customers to edit programs.
Power-off ProtectionAutomatic power-off protection: incomplete cycles are executed automatically after power restoration, ensuring safe operation of the amplification process.
Touchdown PCR and Long PCR (G-Pro only)The TC1000-G-Pro supports Touchdown PCR (-9.9 °C to +9.9 °C) and Long PCR (-9min 59s to +9min 59s) experiments.
Hot Cover SettingsThe temperature and working mode of the hot cover can be set to meet different experimental needs. When the temperature of the heating module is below 30 °C, the hot cover function is turned off automatically.
One-click Rapid IncubationOne click rapid incubation function, meeting the needs of denaturation, enzyme digestion/enzyme-linked immunosorbent assay, ELISA and other experiments.
Tube and Plate CompatibilityCompatible with common PCR tubes, 8-row tubes and 96 well PCR plates without skirt edges and with semi skirt edges.
Progress Display and User AccountsReal time display of program progress and remaining time; user security accounts and passwords can be set according to different customer needs.
WIFI Multi-machine ControlBuilt-in WIFI module, connected to a local area network through a computer host, allowing simultaneous control of multiple PCR machines by one machine.
USB InterfaceUSB interface; supports USB inventory/PCR data retrieval, USB flash drive and LAN software updates, customizable programs, and multiple file storage functions.
Display
7-inch touch panel
Module
1×96
Module range
0–105 °C
Example screen of the TC1000 series 7-inch LCD touch panel showing a running program with step progress and device temperatures
LCD touch panel — example screen.

Specifications General — TC1000-G-Pro, TC1000-S+

ParameterSpecification
BrandALab™ by ACS Material
ModelTC1000-G-Pro, TC1000-S+
SKU #ALTC1000
Product TypeGene amplification instrument (thermal cycler)
Display7-inch LCD touch panel, 1024×600
Sample module temperature control range0–105 °C
Gradient temperature setting rangeTC1000-G-Pro: 30–105 °C
Communication interfaceUSB, WIFI

Specifications by model TC1000-G-Pro · TC1000-S+

ParameterTC1000-G-ProTC1000-S+
Sample Capacity96×0.2mL PCR tube; 12×0.2mL PCR-8 strips; 1×0.2mL 96-well PCR plate96×0.2mL PCR tube; 12×0.2mL PCR-8 strips; 1×0.2mL 96-well PCR plate
Module1×961×96
Sample module temperature control range [°C]0–1050–105
Hot lid temperature control range [°C]30–11530–115
Temperature display accuracy [°C]0.10.1
Temperature control accuracy [°C]±0.1±0.1
Temperature uniformity (at 55 °C) [°C]±0.2±0.2
Maximum rate of temperature change5 °C/Sec5 °C/Sec
Gradient Temp Setting Range [°C]30–105–
Gradient span [°C]1–42 °C, enter 0 to turn off the gradient–
Temperature Control MethodBlock/TubeBlock/Tube
Material of the carrier moduleAluminumAluminum
Display7 inches, LCD 1024×6007 inches, LCD 1024×600
Input methodTouch panelTouch panel
Power off protectYesYes
Communication InterfaceUSB, WIFIUSB, WIFI
Number of program storage20000+ (USB FLASH)20000+ (USB FLASH)
User Defined File SystemUp to 30 steps and 99Up to 30 steps and 99
Power Supply100–120V/200–240V, 50/60HZ, 600W100–120V/200–240V, 50/60HZ, 600W
Dimensions [WxDxH]296×370×295mm296×370×295mm
Weight9.5Kg9.5Kg
Permissible Ambient Temperature and Humidity5–40 °C, 80%RH5–40 °C, 80%RH

Order codes one SKU per configuration

ModelSKU #
TC1000-G-Pro Gradient gene amplification instrumentALT10G00
TC1000-S+ Isometric gene amplification instrumentALT10S00

Parent SKU: ALTC1000. Select the configuration in the order menu.

Where it fits

The TC1000 series is a basic instrument for molecular laboratories: gene detection, molecular cloning, gene expression, mutagenesis and other fields, involving drug discovery, agriculture and the food industry. For PCR optimization with a gradient, choose the TC1000-G-Pro; both models offer the same 1×96 block, 7-inch touch panel, USB and WIFI interfaces and 600 W power supply. Touchdown PCR and Long PCR are listed for the TC1000-G-Pro only.

Frequently asked questions

Which models are in the TC1000 series?

TC1000-G-Pro (Gradient gene amplification instrument) and TC1000-S+ (Isometric gene amplification instrument). Both have a 1×96 module; the specification table lists them side by side.

Which model has the gradient function?

The TC1000-G-Pro: gradient setting range 30–105 °C and gradient span 1–42 °C (enter 0 to turn off the gradient). The gradient fields of the TC1000-S+ show a dash in the specification table.

Which tubes and plates can be used?

Common PCR tubes, 8-row tubes and 96 well PCR plates without skirt edges and with semi skirt edges. The sample capacity of both models is 96×0.2mL PCR tubes, 12×0.2mL PCR-8 strips or one 0.2mL 96-well PCR plate.

What temperature range and uniformity are published?

Sample module temperature control range 0–105 °C, hot lid temperature control range 30–115 °C, temperature control accuracy ±0.1 °C, temperature uniformity (at 55 °C) ±0.2 °C and a maximum rate of temperature change of 5 °C/Sec.

Can several instruments be controlled together, and how is data transferred?

A built-in WIFI module connects the instrument to a local area network through a computer host, allowing one machine to control multiple PCR machines at the same time. The USB interface supports USB inventory/PCR data retrieval and USB flash drive and LAN software updates; 20000+ programs can be stored (USB FLASH).

What are the power supply, size and weight?

Power supply 100–120V/200–240V, 50/60HZ, 600 W. Dimensions 296×370×295 mm (W×D×H); weight 9.5 Kg. Both models have the same values.

What happens after a power failure?

Automatic power-off protection: incomplete cycles are executed automatically after power restoration, ensuring safe operation of the amplification process.

ALab™ TC2000-G1/G2/G3 Thermal Cycler Gradient — single-, dual- and three-channel thermal cyclers with a 10.1-inch touch screen.
ALab™ Accurate 16-T Real-Time Fluorescence Quantitative PCR System — real-time fluorescence quantitative PCR system.
ALab™ MNE-96-03 Fully Automated Nucleic Acid Extraction System — fully automated nucleic acid extraction system.
ALab™ TI470 Blue Light Transilluminator — blue light transilluminator.
ALab™ is a trademark of ACS Material, LLC. Disclaimer: ACS Material, LLC believes the information on this page is accurate and represents the best and most current information available to us. Specifications reflect the current published data; final configurations are confirmed at quotation — always refer to the model datasheet for confirmed model-specific specifications, and follow your laboratory's safety procedures for thermal cycler operation. ACS Material makes no representations or warranties, express or implied, regarding suitability for any purpose, and will not be responsible for damages resulting from use of or reliance upon this information.