GEt Quote

ALab™ D1524 High-Speed Micro Centrifuge & D1524C Hematocrit Centrifuge

In stock
SKU# ALD52S00

Product Detail

ALab™ D1524 High-Speed Micro Centrifuge & D1524C Hematocrit Centrifuge — LCD benchtop centrifuges with a brushless DC motor and 9 programs: D1524 up to 15,000rpm / 21,380 ×g, D1524C up to 12,000rpm / 13,680 ×g with the AC24P capillary-tube rotor.

ALab D1524 and D1524C centrifuges, series image: a white benchtop micro centrifuge in three-quarter view with a flat lid, a blue-framed LCD and control dial at the front right, and a ventilation grille on the right side
Series image shown for reference.

The D1524 high-speed micro centrifuge reaches 15,000rpm (200–15,000rpm in 100rpm increments) and 21,380 ×g; the D1524C hematocrit centrifuge reaches 12,000rpm (200–12,000rpm) and 13,680 ×g and is listed with the AC24P rotor (capillary tubes×24). Both models have an LCD with an intuitive menu, a maintenance-free brushless DC motor, nine acceleration/deceleration rates with soft braking, up to 9 stored programs, speed/RCF conversion, short spin and audible alarm functions, and a dual-lock lid with overspeed, over-temperature and diagnostic systems. The D1524 rotors and adapters of the catalogue are listed with their factory Cat. Nos below.

Why choose the D1524 / D1524C

Speed rangeSpeed range of 200–15000 rpm (D1524) and 200–12000 rpm (D1524C) to meet various experimental needs.
One-handed lid closureMotor lock adsorption design allows one-handed lid closure.
Intuitive LCD operationIntuitive menu and LCD display for easy and clear operation.
Maintenance-free motorMaintenance-free brushless DC motor ensures stable and reliable performance.
Program storageStores up to 9 frequently used programs for quick recall.
Soft brakingNine acceleration/deceleration rates with soft braking for smoother separation.
Speed / RCF and short spinSupports speed/RCF conversion, short spin, and audible alarm functions.
Enhanced safetyDual-lock lid, overspeed, over-temperature, and diagnostic systems for enhanced safety.
Max. speed
15,000rpm / 12,000rpm
Max. RCF
21,380×g / 13,680×g
Programs
9
Weight
8.8kg

Specifications General — D1524 / D1524C

ParameterSpecification
BrandALab™ by ACS Material
ModelD1524 / D1524C
SKU #ALD52S00
Run time30s–99min; HOLD (continuous running)
Acceleration and deceleration time25s up / 25s down
Motor typeBrushless DC motor
Safety performanceDual door lock, over-speed detection, over-temperature detection with internal diagnosis system.
Power requirementsSingle-phase, 200–240V, 50/60Hz, 210W; 100–120V, 50/60Hz, 200W
Dimensions [W×D×H]280×400×240mm
Weight8.8kg
Other functionsRotation speed/RCF switchover, inching operation, running process indicator, sound alert. Adjustable acceleration/deceleration at 9 levels, program storage capacity.

Specifications by model D1524 · D1524C

ParameterD1524D1524C
Max. speed15,000rpm (200–15,000rpm) in 100rpm increments.12,000rpm (200–12,000rpm) in 100rpm increments.
Max. RCF21,380×g, step: 10×g13,680×g, step: 10×g
Capacity24×1.5/2mL, 36×0.5mL, 4×PCR-8 strips, 12×5mL, 18×5mLAC24P (capillary tubes×24)
Run time30s–99min; HOLD (continuous running)30s–99min; HOLD (continuous running)
Acceleration and deceleration time25s up / 25s down25s up / 25s down
Motor typeBrushless DC motorBrushless DC motor
Safety performanceDual door lock, over-speed detection, over-temperature detection with internal diagnosis system.Dual door lock, over-speed detection, over-temperature detection with internal diagnosis system.
Power requirementsSingle-phase, 200–240V, 50/60Hz, 210W; 100–120V, 50/60Hz, 200WSingle-phase, 200–240V, 50/60Hz, 210W; 100–120V, 50/60Hz, 200W
Noise level≤64dB≤65dB
Dimensions [W×D×H]280×400×240mm280×400×240mm
Weight8.8kg8.8kg
Other functionsRotation speed/RCF switchover, inching operation, running process indicator, sound alert. Adjustable acceleration/deceleration at 9 levels, program storage capacity.Rotation speed/RCF switchover, inching operation, running process indicator, sound alert. Adjustable acceleration/deceleration at 9 levels, program storage capacity.

Order codes one SKU per model

ModelSKU #
D1524 · 15,000rpm / 21,380×gALD52400
D1524C · 12,000rpm / 13,680×g · AC24P capillary rotorALD52C00

Parent SKU: ALD52S00. Select the model in the order menu.

Rotors and adapters Cat. Nos as printed in the catalogue; factory catalogue numbers, not ACS SKUs

Rotors by model - D1524 / D1524C

RotorCat. No.Max. speedMax. RCFCapacityRotor materialBiosealingAvailable adapters
AS24-21940006915000rpm21380×g24×0.2/0.5/1.5/2mLAluminum alloyYesA02P2, A05P2
AS18-5 (round bottom)1940007315000rpm21380×g18×5mL (round bottom)Aluminum alloyYes—
AS12-5V (cone bottom)1940007015000rpm21380×g12×5mL (cone bottom)Aluminum alloyYes—
AS36-051940007115000rpm21380×g36×0.2/0.5mLAluminum alloyYesA02P05
AS4-PCR81940007215000rpm21380×g32×0.2mL or 4×0.2mL PCR 8-tube stripAluminum alloyYes—
AC24P (D1524C)—12,000rpm13,680×gCapillary tubes×24———

The catalogue lists these rotors "for D3024 & D1524 & D1524R"; on this page they are listed for the D1524. The D1524C is listed with its own AC24P rotor (capillary tubes ×24) in the specification table.

Available adapters

AdapterCat. No.DescriptionUse
A02P2195000010.2mL rotor adapterUsed with A12-2, A12-2P, AS24-2 and A24-2P rotors; 24pcs/pk
A05P2195000020.5mL rotor adapterUsed with A12-2, A12-2P, AS24-2 and A24-2P rotors; 24pcs/pk
A02P05195000030.2mL rotor adapterUsed with AS36-05 rotor; 36pcs/pk

Cat. Nos as printed. The "used with" text is reproduced from the catalogue and also names rotors of other models that are not listed on this page.

Where it fits

The catalogue states that the high-speed centrifuge is widely used in molecular biology, clinical chemistry, microbiology, as well as clinical diagnostics and scientific research fields. The hematocrit centrifuge measures red blood cell volume and separates micro samples; it supports biochemical, immunological, genetic and clinical tests, bilirubin measurement in neonatal samples and DNA/RNA extraction, and is widely used in clinical and veterinary applications. The D1524 rotors listed on this page are catalogue rotors "for D3024 & D1524 & D1524R"; the D1524C is listed with its own AC24P rotor.

Frequently asked questions

What is the difference between the D1524 and the D1524C?

The D1524 reaches 15,000rpm and 21,380×g and takes tubes of 0.5mL to 5mL and PCR strips; the D1524C is the hematocrit model (12,000rpm, 13,680×g, AC24P capillary tubes×24). Noise level ≤64dB (D1524) and ≤65dB (D1524C); both measure 280×400×240mm and weigh 8.8kg.

What speed and RCF settings are available?

D1524: 200–15,000rpm in 100rpm increments, RCF step 10×g. D1524C: 200–12,000rpm in 100rpm increments, RCF step 10×g.

What control and program functions are listed?

Run time 30s–99min or HOLD (continuous running); acceleration and deceleration time 25s up / 25s down with nine levels; up to 9 stored programs; speed/RCF switchover, inching operation, running process indicator and sound alert.

What safety features are listed?

Dual door lock, over-speed detection and over-temperature detection with an internal diagnosis system.

Which rotors are listed?

For the D1524: AS24-2, AS18-5, AS12-5V, AS36-05 and AS4-PCR8 with Cat. Nos and the adapters A02P2, A05P2 and A02P05. For the D1524C: the AC24P rotor (capillary tubes×24).

What are the power supply options?

Single-phase 200–240V, 50/60Hz, 210W; 100–120V, 50/60Hz, 200W (both models).

ALab™ DG1616 High-Speed Centrifuge & DG1616R High-Speed Refrigerated Centrifuge — DG1616 and DG1616R high speed centrifuges, 16,000 rpm / 28,621 ×g, 4×400 mL, touch control; DG1616R refrigerated.
ALab™ D1524R High-Speed Refrigerated Micro Centrifuge — refrigerated micro centrifuge, 15,000 rpm / 21,380 ×g, −20 to 40°C, 7 minutes pre-cooling to 4°C.
ALab™ D3024 High-Speed Micro Centrifuge — high speed micro centrifuge, 15,000 rpm / 21,380 ×g, 36×0.2/0.5 mL capacity, double cooling air design.
ALab™ DM1424 Hematocrit Centrifuge & DM1224 Economical Hematocrit Centrifuge — DM1424 and DM1224 hematocrit centrifuges, 12,000 rpm / 13,680 ×g, 24 capillary tubes.
ALab™ is a trademark of ACS Material, LLC. Disclaimer: ACS Material, LLC believes the information on this page is accurate and represents the best and most current information available to us. Specifications reflect the current published data; final configurations are confirmed at quotation — always refer to the model datasheet for confirmed model-specific specifications, and follow your laboratory's safety procedures for centrifuge operation. ACS Material makes no representations or warranties, express or implied, regarding suitability for any purpose, and will not be responsible for damages resulting from use of or reliance upon this information.