ALab™ DM1424 Hematocrit Centrifuge & DM1224 Economical Hematocrit Centrifuge
Product Detail
ALab™ DM1424 Hematocrit Centrifuge & DM1224 Economical Hematocrit Centrifuge — 12000rpm / 13680 ×g, LCD, brushless DC motor and the AC24 rotor for 24 capillary tubes.

The DM1424 hematocrit centrifuge (200–12000rpm, increment 10rpm, speed accuracy ±20) offers independent control of speed and time, pulse operation, speed/RCF switch, a short-time run function, an audible alert, automatic rotor identification and an automatic internal diagnosis. The DM1224 economical hematocrit centrifuge (500–12000rpm, increment 100rpm, speed accuracy ±100) offers precise control of speed and time, a maintenance-free brushless DC motor and a door interlock. Both models reach a maximum RCF of 13680 ×g and use the AC24 rotor for 24 capillary tubes.
Why choose the DM1424 / DM1224
Specifications General — DM1424 / DM1224
| Parameter | Specification |
|---|---|
| Brand | ALab™ by ACS Material |
| Model | DM1424 / DM1224 |
| SKU # | ALD14S00 |
| Max. RCF | 13680×g |
| Motor | Brushless DC motor |
| Display | LCD |
| Advanced features | Speed/RCF switch; short-time run function; sound-alert function |
Specifications by model DM1424 · DM1224
| Parameter | DM1424 | DM1224 |
|---|---|---|
| Speed range | 200–12000rpm, increment: 10rpm | 500–12000rpm, increment: 100rpm |
| Max. RCF | 13680×g | 13680×g |
| Speed accuracy | ±20 | ±100 |
| Run time | 30sec–99min/Continuous | 10sec–99min/Continuous |
| Motor | Brushless DC motor | Brushless DC motor |
| Display | LCD | LCD |
| Safety devices | Door interlock, overspeed detector; automatic internal diagnosis, automatic rotor identification | Door interlock |
| Acceleration/braking time | 30s up / 30s down | 40s up / 40s down |
| Power requirements | Single-phase, 200V–240V, 50Hz/60Hz, 5A; 100V–120V, 50Hz/60Hz, 5A; 160W | Single-phase, 200V–240V, 50Hz/60Hz, 5A; 380W |
| Dimension [W×D×H] | 280×364×274mm | 280×364×213mm |
| Weight | 10.5kg | 8.5kg |
| Advanced features | Speed/RCF switch; short-time run function; sound-alert function | Speed/RCF switch; short-time run function; sound-alert function |
Order codes one SKU per model
| Model | SKU # |
|---|---|
| DM1424 · 200–12000rpm · 13680×g · 160W | ALD14200 |
| DM1224 · 500–12000rpm · 13680×g · 380W | ALD12200 |
Parent SKU: ALD14S00. Select the model in the order menu.
Rotor Cat. No. as printed in the catalogue; factory catalogue number, not an ACS SKU
| Rotor | Cat. No. | Host | Max. speed | Max. RCF | Capacity | Rotor material |
|---|---|---|---|---|---|---|
| AC24 | 19400047 | DM1424 & DM1224 | 12000rpm | 13680×g | 24×capillary tubes | High strength aluminum |
Rotor AC24 as printed for the DM1424 and the DM1224.
Where it fits
Frequently asked questions
What is the difference between the DM1424 and the DM1224?
The DM1424 sets 200–12000rpm in 10rpm steps (accuracy ±20), runs 30sec–99min, accelerates and brakes in 30s and adds overspeed detection, automatic internal diagnosis and automatic rotor identification. The DM1224 is the economical model: 500–12000rpm in 100rpm steps (accuracy ±100), 10sec–99min run time, 40s acceleration and braking, door interlock.
What RCF and rotor are listed?
Maximum RCF 13680×g for both models; rotor AC24 (Cat. No. 19400047) for the DM1424 and DM1224, maximum 12000rpm, 24×capillary tubes, high strength aluminum.
What are the power requirements?
DM1424: single-phase, 200V–240V, 50Hz/60Hz, 5A; 100V–120V, 50Hz/60Hz, 5A; 160W. DM1224: single-phase, 200V–240V, 50Hz/60Hz, 5A; 380W.
What are the sizes and weights?
DM1424: 280×364×274mm, 10.5kg. DM1224: 280×364×213mm, 8.5kg.
What advanced features are listed?
Speed/RCF switch, short-time run function and sound-alert function on both models; pulse operation on the DM1424.
What applications are listed?
Determination of erythrocyte fractions in blood, hematocrit values (HCT), micro solution separations, bilirubin determination in neonate blood samples, DNA and RNA extraction, veterinary clinics.