ALab™ Benchtop Meters — Touchscreen Series
Product Detail
ALab™ Touchscreen Series — seven benchtop meters for pH, conductivity and dissolved oxygen, with a high-res 7-inch touch screen and intelligent functions such as automatic calibration and a timing data logger.

The Touchscreen Series covers seven benchtop models: DPH100T (pH/mV and ORP), DEC100T (conductivity, TDS, salinity and resistivity), DDO100T (dissolved oxygen), DPC100T (pH and conductivity), DPD100T (pH and dissolved oxygen), DCD100T (conductivity and dissolved oxygen) and DPCD100T (pH, conductivity and dissolved oxygen, displayed simultaneously). All models have a high-res 7-inch touch screen with navigation by graphics and texts, and intelligent functions such as automatic calibration, automatic temperature compensation, a timing data logger and parameter setup. They store 500 readings per parameter, export data to a flash disk, a PC or a wireless printer (the printer is optional), run on DC12V and have protection class IP54. The photo shows one example setup; it is not a picture of each model, and the beaker and the electrode shown are not included with every model. The tables below give the parameters, the specifications and the included items of each model.
Why choose the Touchscreen Series
Specifications General — DPH100T, DEC100T, DDO100T, DPC100T, DPD100T, DCD100T, DPCD100T
| Parameter | Specification |
|---|---|
| Brand | ALab™ by ACS Material |
| Model | DPH100T, DEC100T, DDO100T, DPC100T, DPD100T, DCD100T, DPCD100T |
| SKU # | ALECBT00 |
| Product Type | Benchtop touchscreen pH / conductivity / dissolved oxygen meters |
| Display | High-res 7-inch touch screen |
| Simultaneous display | pH / conductivity / dissolved oxygen simultaneously: DPCD100T |
| Functions | Automatic calibration, automatic temperature compensation, timing data logger, parameter setup |
| pH calibration | 1 to 5-point calibration for pH mode |
| Data storage | 500 readings/parameter |
| Data export | Flash disk / PC / wireless printer (the printer is optional) |
| Power supply | DC12V |
| Protection class | IP54 |
Models and measured parameters Touchscreen Series
Parameters measured by each model
| Parameter | DPH100T | DEC100T | DDO100T | DPC100T | DPD100T | DCD100T | DPCD100T |
|---|---|---|---|---|---|---|---|
| pH, mV, °C | Yes | – | – | Yes | Yes | – | Yes |
| mV (ORP), °C | Yes | – | – | Yes | Yes | – | Yes |
| Cond., TDS, Sal., Res., °C | – | Yes | – | Yes | – | Yes | Yes |
| DO, °C | – | – | Yes | – | Yes | Yes | Yes |
Technical specifications shared values; the last column names the models each row applies to
Specifications — Touchscreen Series
| Parameter | Specification | Applies to |
|---|---|---|
| pH: Measurement range | (-2.000~20.000)pH | DPH100T, DPC100T, DPD100T, DPCD100T |
| pH: Resolution | 0.01/0.001 | DPH100T, DPC100T, DPD100T, DPCD100T |
| pH: Accuracy | ±0.002pH ±one digit | DPH100T, DPC100T, DPD100T, DPCD100T |
| pH: Calibration points | 1, 2, -5 pts automatic | DPH100T, DPC100T, DPD100T, DPCD100T |
| pH: ATC range | (0.0~100.0)°C/(32.0~212.0)°F | DPH100T, DPC100T, DPD100T, DPCD100T |
| ORP: Measurement range | (-1999.9~+1999.9)mV | DPH100T, DPC100T, DPD100T, DPCD100T |
| ORP: Resolution | 0.1/1 | DPH100T, DPC100T, DPD100T, DPCD100T |
| ORP: Accuracy | ±0.03%F.S ±one digit | DPH100T, DPC100T, DPD100T, DPCD100T |
| Conductivity: Measurement range | 0~2000.0mS/cm, Auto-ranging: 0~19.999μS/cm; 20.0~199.9μS/cm; 200~1999μS/cm; 2.00~19.99mS/cm; 20.00~199.9mS/cm; 200.0~2000mS/cm (K=10). Match test range: 0~200mS/cm. TDS: 0~100.0g/L (TDS factor adjustable). Resistivity: 5.000Ω·cm~100.0MΩ·cm. Salinity: 0~100ppt | DEC100T, DPC100T, DCD100T, DPCD100T |
| Conductivity: Calibration points | one point | DEC100T, DPC100T, DCD100T, DPCD100T |
| Conductivity: Resolution | 0.001 | DEC100T, DPC100T, DCD100T, DPCD100T |
| Conductivity: ATC range | (0.0~50.0)°C/(32.0~122.0)°F | DEC100T, DPC100T, DCD100T, DPCD100T |
| Conductivity: Accuracy | ±0.5 % F.S ±one digit | DEC100T, DPC100T, DCD100T, DPCD100T |
| DO: Measurement range | (0.00~20.00)mg/L | DDO100T, DPD100T, DCD100T, DPCD100T |
| DO: Accuracy | ±0.30 mg/L | DDO100T, DPD100T, DCD100T, DPCD100T |
| DO: DO saturation | (0.0~200.0)% | DDO100T, DPD100T, DCD100T, DPCD100T |
| DO: Automatic barometric pressure compensation | (0~200.0)kPa | DDO100T, DPD100T, DCD100T, DPCD100T |
| DO: Automatic temperature compensation | (0.0~50.0)°C/(32.0~122.0)°F | DDO100T, DPD100T, DCD100T, DPCD100T |
| DO: Manual salinity compensation | 0~45ppt | DDO100T, DPD100T, DCD100T, DPCD100T |
| Temperature: Measurement range | (0.0~100.0)°C/(32.0~212.0)°F | All models |
| Temperature: Accuracy | ±0.2°C | All models |
| Others: Data export | Flash disk/PC/Printer | All models |
| Others: Power supply | DC12V | All models |
Each row applies to the models named in the last column.
Included items by model
Test kit — included items by model
| Item | DPH100T | DEC100T | DDO100T | DPC100T | DPD100T | DCD100T | DPCD100T |
|---|---|---|---|---|---|---|---|
| Meter | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
| Glass refillable combination pH probe 201G | Yes | – | – | Yes | Yes | – | Yes |
| Stainless-steel temperature probe TEMP-01 | Yes | – | – | Yes | Yes | – | Yes |
| Glass ATC conductivity probe CON201TG, K=1.0 | – | Yes | – | Yes | – | Yes | Yes |
| Polarographic DO probe DO01-2M | – | – | Yes | – | Yes | Yes | Yes |
| pH buffer solution: pH4.00/7.00/10.01, 50mL, one for each | Yes | – | – | Yes | Yes | – | Yes |
| Standard Cond solution: 84μS/1413μS/12.88mS/cm, 50mL, one for each | – | Yes | – | Yes | – | Yes | Yes |
| Membrane refill solution: DOS-01, 30mL, 1btl | – | – | Yes | – | Yes | Yes | Yes |
| Membrane sensor caps DOSC: 3pcs/group, 1pkg | – | – | Yes | – | Yes | Yes | Yes |
| PC cable: 1pc | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
| Flexible probe holder F01: 1pc | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
| Magnetic stirrer: 1pc | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
| Power adaptor | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
Only the items marked Yes are included with that model. The wireless printer is optional and is not included.
Order codes one SKU per configuration
| Model | SKU # |
|---|---|
| DPH100T Benchtop Touchscreen pH Meter | ALDPHT00 |
| DEC100T Benchtop Touchscreen Conductivity Meter | ALDECT00 |
| DDO100T Benchtop Touchscreen Dissolved Oxygen Meter | ALDDOT00 |
| DPC100T Benchtop Touchscreen pH/Conductivity Meter | ALDPCT00 |
| DPD100T Benchtop Touchscreen pH/Dissolved Oxygen Meter | ALDPDT00 |
| DCD100T Benchtop Touchscreen Conductivity/Dissolved Oxygen Meter | ALDCDT00 |
| DPCD100T Benchtop Touchscreen pH/Conductivity/Dissolved Oxygen Meter | ALDP0500 |
Parent SKU: ALECBT00. Select the configuration in the order menu.
Package contents
| Supplied with the instrument | Qty |
|---|---|
| ALab™ benchtop meter of the selected model, with the items marked for that model in the Included items table above | By model |
Package contents reflect the current published configuration; the itemized bill of materials is confirmed on the quotation.
Where it fits
Frequently asked questions
Which models are in the Touchscreen Series?
DPH100T, DEC100T, DDO100T, DPC100T, DPD100T, DCD100T and DPCD100T. DPH100T, DEC100T and DDO100T measure one parameter group (pH/mV and ORP, conductivity, or dissolved oxygen); DPC100T, DPD100T, DCD100T and DPCD100T combine them.
Which parameters does each model measure?
See the table Parameters measured by each model: DPH100T pH/mV and mV(ORP); DEC100T conductivity/TDS/salinity/resistivity; DDO100T dissolved oxygen; DPC100T pH, mV(ORP) and conductivity; DPD100T pH, mV(ORP) and dissolved oxygen; DCD100T conductivity and dissolved oxygen; DPCD100T all four. Temperature is measured by all models.
Which model displays pH, conductivity and dissolved oxygen simultaneously?
The DPCD100T displays pH, conductivity and dissolved oxygen simultaneously.
How many readings can be stored and how is data exported?
The meters store 500 readings per parameter. Data can be exported to a flash disk, a PC or a wireless printer; the printer is optional.
What is included with each model?
The PC cable, the flexible probe holder, the magnetic stirrer and the power adaptor are listed for every model. Probes, buffer and standard solutions, membrane refill solution and membrane sensor caps are listed per model in the Included items table; only the items marked Yes are included.
What are the power supply and protection class?
The meters use DC12V and have protection class IP54.