GEt Quote

ALab™ DispensMate Bottle-Top Dispenser

In stock
SKU# ALDSPM

Product Detail

ALab™ DispensMate Bottle-Top Dispenser is a manual bottle-top dispenser for routine reagent delivery. Six catalog configurations are listed below, spanning 0.5 mL to 60 mL, each with its own graduation and error specification, at a systematic error of ±0.5% and a random error of ±0.2%. Components made of PTFE, FEP, BSG and PP provide chemical resistance and strength, liquid-accessible parts are fully autoclavable at 121 °C, and calibration conforms to ISO 8655. The dispenser is supplied with the S40, GL32, GL38, GL25 and GL28 adapters.

ALab DispensMate bottle-top dispenser with graduated barrel, blue adjustment collar and discharge tube with closure cap, mounted on an amber reagent bottle
ALab™ DispensMate — manual bottle-top dispensing with a smooth piston, closure cap and adapter set. The reagent bottle shown is listed as an accessory.

Why choose the DispensMate

Chemical-resistant componentsComponents made of PTFE, FEP, BSG and PP — inert, high-strength materials providing chemical resistance.
Autoclavable at 121 °CLiquid-accessible parts are fully autoclavable at 121 °C, and the dispenser is easy to disassemble and clean for periodic maintenance.
Six listed configurationsFrom 0.5–5 mL to 5.0–60 mL, each with its own graduation and error specification.
Adapter set suppliedSupplied with the S40, GL32, GL38, GL25 and GL28 adapters to fit most laboratory reagent bottles. A closure cap protects the user from exposure to the reagent.
Range Across 6 Configurations
0.5–60 mL
Systematic Error
±0.5%
Calibration
ISO 8655

Models, volume ranges and accuracy

Volume rangeCat. No.SKU #GraduationSystematic errorRandom error
0.5–5 mL7032100101ALDSPM010.1 mL±25 µL · ±0.5%±10 µL · ±0.2%
1.0–10 mL7032100102ALDSPM020.2 mL±50 µL · ±0.5%±20 µL · ±0.2%
2.5–25 mL7032100103ALDSPM050.5 mL±125 µL · ±0.5%±50 µL · ±0.2%
2.5–30 mL7032100106ALDSPM030.5 mL±150 µL · ±0.5%±60 µL · ±0.2%
5.0–50 mL7032200104ALDSPM061.0 mL±250 µL · ±0.5%±100 µL · ±0.2%
5.0–60 mL7032100107ALDSPM041.0 mL±300 µL · ±0.5%±120 µL · ±0.2%

The table lists both percentage and absolute microlitre error values for each configuration.

Product specifications

The following specifications are common to all six listed configurations.

ParameterDispensMate
BrandALab™ by ACS Material
TypeManual bottle-top dispenser
Volume RangeBy model — see the table above
Systematic Error±0.5%
Random Error±0.2%
CalibrationConforms to ISO 8655
Component MaterialsPTFE, FEP, BSG, PP
AutoclavingFully autoclavable at 121 °C — liquid-accessible parts only
Volume AdjustmentManual, via the adjustment slider on the barrel
DischargeDischarge tube with closure cap
Adapters SuppliedS40 · GL32 · GL38 · GL25 · GL28
MaintenanceDesigned to be disassembled and cleaned for periodic maintenance
Dimensions · WeightConfirm at quotation

Accessories

AccessoryCat. No.
GL32 adapter, 45/32 mm17400131
GL38 adapter, 45/38 mm17400132
GL25 adapter, 32/25 mm17400133
GL28 adapter, 32/28 mm17400134
S40 adapter, 45/40 mm17400135
GL45 adapter, 45 mm17100553
Reagent bottle, brown, 1 L17400037
Filling tube (m)17400021
Discharge tube (m)17100073
Discharge tube combination, adapter 25 mL / 50 mL17100696
Discharge tube combination, adapter 5 mL / 10 mL17100767

Package contents

ItemStatus
ACS sales unit1 unit
AdaptersS40, GL32, GL38, GL25 and GL28 supplied
Reagent bottleAvailable as an accessory, Cat. No. 17400037; package inclusion is confirmed at quotation
Package contents and configurationConfirm at quotation
Options and spare partsConfirm at quotation

The reagent bottle shown in the product image is listed as accessory Cat. No. 17400037; package inclusion is confirmed at quotation. Package contents and configuration details: confirm at quotation.

Where it fits · The dispensing range

The manual position in the ALab™ dispensing range. The range also includes the DispensMate-Pro and DispensMate-HF bottle-top dispensers, the dFlow and dFlow-Pro electronic bottle-top dispensers, and the dTrite-Pro electronic burette. The DispensMate is the manual model: volume set by hand on the barrel, components in inert, high-strength materials, autoclavable liquid-accessible parts and an adapter set supplied as standard. For electronic, touchscreen-controlled dispensing, see the dFlow-Pro.

FAQ

Which configuration should I choose?

Six configurations are listed: 0.5–5, 1.0–10, 2.5–25, 2.5–30, 5.0–50 and 5.0–60 mL. Graduation increases with range, from 0.1 mL on the smallest to 1.0 mL on the largest, so the smallest range that covers the volume you dispense gives the finest setting increment.

Which component materials are listed?

PTFE, FEP, BSG and PP are used in the dispenser components. Confirm chemical compatibility for the intended reagent and concentration.

Can it be autoclaved?

Liquid-accessible parts are fully autoclavable at 121 °C. This applies to the liquid-accessible parts only, not the complete assembly.

Which bottles does it fit?

The dispenser is supplied with the S40, GL32, GL38, GL25 and GL28 adapters. A GL45 adapter is listed as accessory Cat. No. 17100553.

Is a reagent bottle supplied?

The brown 1 L reagent bottle is listed as accessory Cat. No. 17400037. Package inclusion is confirmed at quotation. The bottle shown in the product image illustrates the mounted configuration.

What accuracy is specified?

Systematic error is listed as ±0.5% and random error as ±0.2% for all six configurations. The corresponding absolute microlitre values are shown in the model table. Calibration conforms to ISO 8655.

Are dimensions and weight available?

Dimensions and weight: confirm at quotation.

Related

DispensMate-Pro Bottle-Top Dispenser — related mechanical bottle-top dispensing product.
DispensMate-HF Bottle-Top Dispenser — related bottle-top dispensing product.
dFlow-Pro Electronic Bottle-Top Dispenser — related electronic bottle-top dispensing product.

ALab™ is a trademark of ACS Material, LLC. Disclaimer: ACS Material, LLC believes the information on this page is accurate and represents the best and most current information available to us. Specifications are typical and may vary. Refer to the current Technical Data Sheet and quotation for order-specific specifications and configuration details. Confirm chemical compatibility for the intended reagent before use, and follow applicable laboratory safety procedures for handling acids, bases and solvents. ACS Material makes no representations or warranties, express or implied, regarding suitability for any purpose, and will not be responsible for damages resulting from use of or reliance upon this information.