GEt Quote

ALab™ DispensMate Bottle-Top Dispenser

In stock
SKU# ALDSPM

Product Detail

The ALab™ DispensMate is a bottle-top dispenser for handling chemicals directly from the bottle, in six volume ranges from 0.5 to 5 mL up to 5.0 to 60 mL. Every range has a systematic error of ±0.5% and a random error of ±0.2%, with calibration conforming to ISO 8655.

ALab™ DispensMate bottle-top dispenser
ALab™ DispensMate bottle-top dispenser — image shown for reference.

Inert, high-strength components of PTFE, FEP, borosilicate glass (BSG) and PP are used, and all liquid-contact parts are autoclavable at 121°C. The volume is easy to adjust, and the piston runs smoothly.

A closure cap protects the user from exposure to the reagent, and the dispenser is easy to disassemble and clean for periodic maintenance. It is supplied with S40, GL32, GL38, GL25 and GL28 bottle adapters.

Why choose the DispensMate

Chemical resistanceInert, high-strength PTFE, FEP, BSG and PP components.
AutoclavableAll liquid-contact parts are autoclavable at 121°C.
Six volume rangesFrom 0.5 to 5 mL up to 5.0 to 60 mL, each ±0.5% systematic and ±0.2% random error.
Easy volume adjustmentSimple setting of the dispensing volume, and a smooth-running piston.
User protectionA closure cap protects the user from exposure to the reagent.
Bottle adaptersSupplied with S40, GL32, GL38, GL25 and GL28 adapters; easy to disassemble and clean.
Ranges
6
Volume
0.5 to 60 mL
Systematic error
±0.5%
Random error
±0.2%
Liquid-contact parts
Autoclavable at 121°C

Specifications General — DispensMate, six volume ranges

ParameterSpecification
BrandALab™ by ACS Material
ModelDispensMate
Product typeBottle-top dispenser
Volume ranges0.5 to 5, 1.0 to 10, 2.5 to 25, 2.5 to 30, 5.0 to 50, 5.0 to 60 mL
Systematic error±0.5% (all ranges)
Random error±0.2% (all ranges)
CalibrationConforms to ISO 8655
MaterialsPTFE, FEP, borosilicate glass (BSG), PP
Autoclaving121°C (liquid-contact parts only)
Adapters suppliedS40, GL32, GL38, GL25, GL28

Volume ranges and accuracy per configuration

Volume range (mL)Graduation (mL)Systematic error (µL)Systematic error (%)Random error (µL)Random error (%)ACS Cat. No.
0.5 to 50.1±25±0.5±10±0.2ALDSPM01
1.0 to 100.2±50±0.5±20±0.2ALDSPM02
2.5 to 250.5±125±0.5±50±0.2ALDSPM05
2.5 to 300.5±150±0.5±60±0.2ALDSPM03
5.0 to 501.0±250±0.5±100±0.2ALDSPM06
5.0 to 601.0±300±0.5±120±0.2ALDSPM04

Systematic and random error per the published specification for each volume range.

Adapters and accessories

AccessoryStatus
GL32 adapter, 45/32 mmSupplied
GL38 adapter, 45/38 mmSupplied
GL25 adapter, 32/25 mmSupplied
GL28 adapter, 32/28 mmSupplied
S40 adapter, 45/40 mmSupplied
Reagent bottle, brown, 1 LListed
Filling tube (per m)Listed
Discharge tube (per m)Listed
GL45 adapter, 45 mmListed
Discharge tube combination (for 25 and 50 mL)Listed
Discharge tube combination (for 5 and 10 mL)Listed

The table above lists bottle adapters and accessories.

Order codes one ACS Cat. No. per configuration

Model / configurationACS Cat. No.
DispensMate, 0.5 to 5 mLALDSPM01
DispensMate, 1.0 to 10 mLALDSPM02
DispensMate, 2.5 to 30 mLALDSPM03
DispensMate, 5.0 to 60 mLALDSPM04
DispensMate, 2.5 to 25 mLALDSPM05
DispensMate, 5.0 to 50 mLALDSPM06

Parent ACS Cat. No.: ALDSPM. Select the configuration in the order menu.

Package contents

Supplied with the instrumentQty
DispensMate bottle-top dispenser of the selected volume range1
Bottle adapters S40, GL32, GL38, GL25 and GL28Included

Where it fits

The DispensMate suits routine dispensing of reagents and solvents directly from the bottle in pharmacology, biotechnology, healthcare, food and beverage, chemistry, environmental monitoring, and academic research laboratories. Choose the range by the volume dispensed, and check chemical compatibility for the intended reagent and concentration. For hydrofluoric acid, use the DispensMate-HF.

Frequently asked questions

Which volume ranges are available?

Six ranges: 0.5 to 5, 1.0 to 10, 2.5 to 25, 2.5 to 30, 5.0 to 50 and 5.0 to 60 mL.

How accurate is the DispensMate?

Every range has a systematic error of ±0.5% and a random error of ±0.2%; the values in µL per range are in the accuracy table. Calibration conforms to ISO 8655.

Which materials are in contact with the liquid?

Inert, high-strength PTFE, FEP, borosilicate glass (BSG) and PP components.

Can it be autoclaved?

Yes, the liquid-contact parts are autoclavable at 121°C.

Which bottle adapters are supplied?

S40, GL32, GL38, GL25 and GL28 bottle adapters are supplied. Other listed accessories appear in the table above.

ALab™ DispensMate-Pro Bottle-Top Dispenser — bottle-top dispenser in five volume ranges from 0.5 to 100 mL.
ALab™ DispensMate-HF Hydrofluoric Acid Bottle-Top Dispenser — bottle-top dispenser for hydrofluoric acid, 1.0 to 10 mL.
ALab™ dFlow Electronic Bottle-Top Dispenser — motorized electronic bottle-top dispenser, 10 mL piston.
ALab™ is a trademark of ACS Material, LLC. Disclaimer: ACS Material, LLC believes the information on this page is accurate and represents the best and most current information available to us. Specifications reflect the current published data; refer to the model-specific specifications and follow your laboratory's safety procedures for bottle-top dispenser operation. ACS Material makes no representations or warranties, express or implied, regarding suitability for any purpose, and will not be responsible for damages resulting from use of or reliance upon this information.