ALab™ DispensMate-Pro Bottle-Top Dispenser is a bottle-top dispenser for reagent delivery directly from the bottle. Five catalog configurations are listed below, spanning 0.5 mL to 100 mL, each with its own graduation. All five configurations are specified at a systematic error of ±0.5% and a random error of ±0.2%. Listed component materials are inert materials with a glass/PTFE piston. A volume-locking mechanism sets the volume on a clear scale, a reagent recovery function reduces reagent waste, and an adjustable aspirating tube accommodates different bottle heights.

Why choose the DispensMate-Pro
Configurations, Cat. Nos. and accuracy
| Volume range | Cat. No. | SKU # | Graduation | Systematic error | Random error |
|---|---|---|---|---|---|
| 0.5–5 mL | 7032212001 | ALDSPP01 | 0.1 mL | ±25 µL · ±0.5% | ±10 µL · ±0.2% |
| 1.0–10 mL | 7032212002 | ALDSPP02 | 0.2 mL | ±50 µL · ±0.5% | ±20 µL · ±0.2% |
| 2.5–25 mL | 7032212003 | ALDSPP03 | 0.5 mL | ±125 µL · ±0.5% | ±50 µL · ±0.2% |
| 5.0–50 mL | 7032111004 | ALDSPP04 | 1.0 mL | ±250 µL · ±0.5% | ±100 µL · ±0.2% |
| 10–100 mL | 7032111005 | ALDSPP05 | 2.0 mL | ±500 µL · ±0.5% | ±200 µL · ±0.2% |
Systematic error is ±0.5% and random error ±0.2% for all five listed configurations; the table gives the corresponding absolute microlitre values for each configuration. Cat. No. identifies the configuration; the ALDSPP code is the ACS Material sales SKU for the same configuration.
Product specifications
The following specifications are common to all five listed configurations.
| Parameter | DispensMate-Pro |
|---|---|
| Brand | ALab™ by ACS Material |
| Type | Bottle-top dispenser |
| Volume Range | By configuration — see the table above |
| Systematic Error | ±0.5% |
| Random Error | ±0.2% |
| Component Materials | Inert materials, with a glass/PTFE piston |
| Autoclaving | Fully autoclavable at 121 °C |
| Volume Setting | Volume-locking mechanism on a clear scale |
| Reagent Recovery | Reagent recovery function; helps prevent dripping when not in use |
| Aspirating Tube | Adjustable for different bottle heights |
| Adapters Supplied | S40 · GL32 · GL38 · GL25 · GL28 |
| Maintenance | Designed to be disassembled and cleaned for periodic maintenance |
| Dimensions · Weight | Confirm at quotation |
Accessories
| Accessory | Cat. No. |
|---|---|
| GL32 adapter, 45/32 mm | 17000817 |
| GL38 adapter, 45/38 mm | 17400132 |
| GL25 adapter, 32/25 mm | 17400133 |
| GL28 adapter, 32/28 mm | 17400134 |
| S40 adapter, 45/40 mm | 17400135 |
| Reagent bottle, brown, 1 L | 17400037 |
| Filling tube combination | 17900158 |
| Discharge tube (m), for 25 / 50 / 100 mL configurations | 17000802 |
| Discharge tube (m), for 5 / 10 mL configurations | 17100735 |
| Discharge tube combination, for 25 / 50 / 100 mL configurations | 17900236 |
| Discharge tube combination, for 5 / 10 mL configurations | 17900237 |
Package contents
| Item | Status |
|---|---|
| ACS sales unit | 1 unit |
| Adapters | S40, GL32, GL38, GL25 and GL28 supplied |
| Reagent bottle | Listed as accessory Cat. No. 17400037; package inclusion is confirmed at quotation |
| Package contents and configuration | Confirm at quotation |
| Options and spare parts | Confirm at quotation |
Package contents and configuration details: confirm at quotation.
A bottle-top dispensing option with volume locking, reagent recovery, an adjustable aspirating tube and configurations extending to 100 mL. The ALab™ dispensing range also includes the DispensMate bottle-top dispenser, the DispensMate-HF for hydrofluoric acid, the dFlow and dFlow-Pro electronic bottle-top dispensers, and the dTrite-Pro electronic burette. For electronic, touchscreen-controlled dispensing, see the dFlow-Pro.
FAQ
Which configuration should I choose?
Five configurations are listed: 0.5–5, 1.0–10, 2.5–25, 5.0–50 and 10–100 mL. Graduation increases with range, from 0.1 mL on the smallest to 2.0 mL on the largest, so the smallest range that covers the volume you dispense gives the finest setting increment.
What accuracy is listed?
Systematic error is listed as ±0.5% and random error as ±0.2% for all five configurations. The corresponding absolute microlitre values are shown per configuration in the table above.
Which component materials are listed?
Inert materials, with a glass/PTFE piston. Confirm chemical compatibility for the intended reagent and concentration.
Can it be autoclaved?
It is listed as fully autoclavable at 121 °C. Follow your laboratory’s autoclaving procedure for the parts concerned.
Which bottle threads are covered?
The dispenser is supplied with the S40, GL32, GL38, GL25 and GL28 adapters. Each is also listed separately in the accessories table.
What does the adjustable aspirating tube do?
It is adjustable for different bottle heights, so the same dispenser can be fitted to reagent bottles of differing depth.
Is a reagent bottle supplied?
The brown 1 L reagent bottle is listed as accessory Cat. No. 17400037. Package inclusion is confirmed at quotation.
Are dimensions and weight available?
Dimensions and weight: confirm at quotation.
Related
ALab™ is a trademark of ACS Material, LLC. Disclaimer: ACS Material, LLC believes the information on this page is accurate and represents the best and most current information available to us. Specifications are typical and may vary. Refer to the current Technical Data Sheet and quotation for order-specific specifications and configuration details. Confirm chemical compatibility for the intended reagent and concentration before use, and follow applicable laboratory safety procedures for handling acids, bases and solvents. ACS Material makes no representations or warranties, express or implied, regarding suitability for any purpose, and will not be responsible for damages resulting from use of or reliance upon this information.