ALab™ DM0424 / DM0408 Multi-Purpose Low-Speed Centrifuge
Product Detail
ALab™ DM0424 / DM0408 Multi-Purpose Low-Speed Centrifuge — two multi-purpose low-speed centrifuges up to 4000rpm: the DM0424 (2500×g, swing-out and angle rotors up to 4×50mL) and the DM0408 (1900×g, angle rotor 8×15mL).

Multi-purpose low speed centrifuges are versatile and can be used in applications from clinical to biochemical for qualitative analysis of serum, plasma, blood, and urine. Both models reach 4000rpm, the speed can be set in RPM/RCF, and three routine programs are stored (Blood 3200rpm 10min, Urine 1800rpm 5min, Faecal 1300rpm 10min). The DM0424 (LCD) reaches 2500×g and takes seven optional rotors, swing-out and angle, up to 4×50mL; the DM0408 (LED) reaches 1900×g with the A8-15P angle 8×15mL rotor (default) or the A12-10P angle 12×10mL or 8×15mL rotor.
Why choose the DM0424 / DM0408
Specifications General — DM0424 / DM0408
| Parameter | Specification |
|---|---|
| Brand | ALab™ by ACS Material |
| Models | DM0424, DM0408 |
| SKU # | ALD42400 (DM0424), ALD40800 (DM0408) |
| Product Type | Multi-purpose low-speed centrifuge |
| Max. speed | 4000rpm (both models) |
| Speed accuracy | ±100rpm |
| Run time | 1-99min, HOLD |
| Motor | Brushless DC motor |
| Program | Blood: 3200rpm, 10min; Urine: 1800rpm, 5min; Faecal: 1300rpm, 10min |
| Safety device | Automatic internal diagnosis |
| Power requirements | Single phase, 100-240V, 50Hz/60Hz (110W DM0424; 85W DM0408) |
Specifications by model DM0424 · DM0408
| Specification | DM0424 | DM0408 |
|---|---|---|
| SKU # | ALD42400 | ALD40800 |
| Speed range | 500-4000rpm, increment: 100rpm | 300-4000rpm, increment: 100rpm |
| Max. RCF | 2500×g | 1900×g |
| Speed accuracy | ±100rpm | ±100rpm |
| Rotor | Optional: S6-15, S4-50, SE6-15P, A24-15P, AE24-15, A8-15P, A12-10P | A8-15P angle 8×15mL (default); A12-10P angle 12×10mL or 8×15mL |
| Run time | 1-99min, HOLD | 1-99min, HOLD |
| Motor | Brushless DC motor | Brushless DC motor |
| Display | LCD | LED |
| Program | Blood: 3200rpm, 10min; Urine: 1800rpm, 5min; Faecal: 1300rpm, 10min | Blood: 3200rpm, 10min; Urine: 1800rpm, 5min; Faecal: 1300rpm, 10min |
| Safety device | Automatic internal diagnosis | Automatic internal diagnosis |
| Acceleration/deceleration | 3 up / 4 down steps | 25s up / 35s down |
| Power requirements | Single phase, 100-240V, 50Hz/60Hz, 110W | Single phase, 100-240V, 50Hz/60Hz, 85W |
| Dimension (W×D×H) | 364×440×268mm | 286×367×227mm |
| Weight | 14.5kg | 9.2kg |
| Noise level | ≤62dB(A) | ≤60dB(A) |
Order codes one SKU per model
| Model | SKU # |
|---|---|
| DM0424 Multi-Purpose Low-Speed Centrifuge | ALD42400 |
| DM0408 Multi-Purpose Low-Speed Centrifuge | ALD40800 |
Parent SKU: ALD424G0. Select the configuration in the order menu.
Rotors by model; Cat. Nos as printed in the catalogue
Listed by Cat. No. for reference; not selectable in the order menu.
Adapters Cat. Nos as printed in the catalogue
Listed by Cat. No. for reference; not selectable in the order menu.
Where it fits
Frequently asked questions
What is the difference between the DM0424 and the DM0408?
The DM0424 runs 500-4000rpm (2500×g) with swing-out and angle rotors, an LCD display, 3 up / 4 down steps, 110W, 364×440×268mm and 14.5kg. The DM0408 runs 300-4000rpm (1900×g) with angle rotors, an LED display, 25s up / 35s down, 85W, 286×367×227mm and 9.2kg.
Which routine programs are stored?
Blood: 3200rpm, 10min; Urine: 1800rpm, 5min; Faecal: 1300rpm, 10min (both models).
Which rotors fit each model?
DM0424: seven optional rotors, S6-15, S4-50, SE6-15P, A24-15P, AE24-15, A8-15P and A12-10P. DM0408: A8-15P (8×15mL, the default rotor) and A12-10P (8×15mL or 12×10mL).
Which adapters are listed?
A15P30 (50mL change 15mL, for S4-50), A15P22 (15mL, for S6-15, A24-15P, A8-15P), A5P17 (5mL, 13×75mm blood collection tube) and A2P17 (optional, 1.5/2mL).
What is the run time?
1-99min, or HOLD.
What are the power requirements?
Single phase, 100-240V, 50Hz/60Hz; 110W (DM0424) or 85W (DM0408).