ALab™ DM0506 Low-Speed Centrifuge

In stock
SKU# ALDM050F

Product Detail

ALab™ DM0506 Low-Speed Centrifuge separates serum, plasma, urine and faecal samples in biochemical and medical laboratories. It runs from 300 to 5000 rpm in 10 rpm steps and both published rotor configurations are rated to 5000 rpm and 2600 ×g — A6-15P for 6 × 15 mL and A4-50P for 4 × 50 mL. Speed or g-force can be set and displayed directly, two programs are preloaded, and the lid releases automatically at the end of a run. This model is also supplied unbranded as the CF0506.

ALab DM0506 low-speed centrifuge with transparent lid, loaded rotor and ACS Material branding
ALab™ DM0506 — 5000 rpm and 2600 ×g on both rotors, with two preloaded programs and a transparent lid

Why choose the DM0506

2600 ×g on both rotorsBoth published rotor configurations, A6-15P and A4-50P, share the same 5000 rpm and 2600 ×g maxima — moving from 15 mL to 50 mL work does not reduce the published maximum.
Two preloaded programsP1 and P2 start a stored procedure with one key, which suits a laboratory running the same two protocols repeatedly.
Set in rpm or in gSpeed is set in 10 rpm increments and relative centrifugal force in 10 ×g increments, both selectable and displayed.
Two deceleration settingsTwo selectable deceleration settings, as published.
Speed Range
300–5000 rpm
Max. RCF
2600 ×g
Footprint
300 × 240 mm

Product specifications

ParameterDM0506
BrandALab™ by ACS Material
SKU #ALDM0506
Speed Range300–5000 rpm, increment 10 rpm
Max. RCF2600 ×g, increment 10 ×g
Speed Accuracy±20 rpm
Rotor Capacity6 × 1.5–5 / 7 / 10 / 15 mL · 4 × 20 / 50 mL
Run Time30 sec – 99 min, HD (continuous running)
DisplayLCD
Preloaded ProgramP1 / P2
Acceleration / Deceleration1 ↑ / 2 ↓
Safety DevicesDoor interlock · Overspeed detector · Automatic internal diagnosis
MotorBrushless DC motor
Power RequirementsSingle-phase 100–240 V, 50/60 Hz, 70 W
Dimensions [W×D×H]300 × 240 × 180 mm
Weight5.2 kg
Alternative model nameCF0506 (unbranded version of the same instrument)

Rotors and adapters

Both rotors are high-strength plastic and share the same published maxima. Two adapters extend the A6-15P to smaller tube formats; the tube dimensions each adapter accepts are published, but not a separate radius or maximum RCF for those configurations.

ItemCat. No.Max. speedMax. RCFCapacity
A6-15P rotor194002955000 rpm2600 ×g6 × 15 mL
A4-50P rotor194002945000 rpm2600 ×g4 × 50 mL
A5P17 adapter195000225 mL, for 13 × 75 mm blood collection tubes · applied to A6-15P
A2P17 adapter195000231.5 / 2 mL, for 11 × 43 mm centrifuge tubes and cryogenic vials · applied to A6-15P
A6-15P six-place 15 mL rotor for the ALab DM0506, Cat. No. 19400295A4-50P four-place 50 mL rotor for the ALab DM0506, Cat. No. 19400294
Left: A6-15P for 6 × 15 mL. Right: A4-50P for 4 × 50 mL. Both are published at 5000 rpm and 2600 ×g.
A5P17 5 mL adapter for 13 by 75 mm blood collection tubes, ALab DM0506, Cat. No. 19500022A2P17 1.5 and 2 mL adapter for 11 by 43 mm tubes and cryogenic vials, ALab DM0506, Cat. No. 19500023
Adapters for the A6-15P rotor. Left: A5P17 for 13 × 75 mm blood collection tubes. Right: A2P17 for 11 × 43 mm tubes and cryogenic vials.

Package contents

Supplied with the instrumentQty
DM0506 low-speed centrifuge1
A5P17 and A2P17 adapters (19500022, 19500023)1 set
Rotor configurationConfirm at quotation

Package contents reflect the current published configuration; the itemized bill of materials is confirmed on the quotation.

Where it fits · The centrifuge range

The highest published maximum RCF among the low-speed models here, on either rotor. The DM0412(A6-50P) configuration is published at 1800 ×g and the Q0408E at 1860 ×g, while the DM0506 publishes 2600 ×g for both of its rotor configurations, from a 300 × 240 mm footprint. For the widest range of vacuum blood collection tube sizes see the DM0412; for PRP, PRF and CGF programming see the Q0408E; for microtubes and PCR formats see the D1008.

Is this the right centrifuge for your tubes?

Both DM0506 rotors are published at the same 5000 rpm and 2600 ×g maximum, so the choice between them is a question of tube format rather than of g-force. Where an adapter is used to carry smaller tubes, the adapter and its tube dimensions are published but not a separate radius or path-specific RCF — the tool below flags those configurations for confirmation rather than assuming the rotor maximum applies.

Model: RCF = r · ω² / g with ω = 2πN/60 and g = 9.80665 m/s², equivalent to RCF = 1.118 × 10⁻⁵ · r[cm] · N². Each configuration carries its own radius, labelled published where the published data state it and derived where it is back-calculated from the published maximum speed and RCF. Neither value is a measured value. Selection resolves a tube / rotor / adapter path and checks the path-specific RCF where it is published; otherwise the configuration is flagged for confirmation. It does not account for refrigeration, throughput, footprint or price. A schematic teaching tool, not selection software.

FAQ

Is the CF0506 a different machine?

No. CF0506 is the same instrument supplied without branding. Specifications, rotors and adapters are identical.

Do both rotors really reach 2600 ×g?

Yes — 5000 rpm and 2600 ×g are published for both the A6-15P and the A4-50P.

What RCF do I get with the 5 mL or 1.5/2 mL adapters?

The tube dimensions each adapter accepts are published, but not a separate radius or maximum RCF for those configurations. Because an adapter changes the radius at which the sample sits, the rotor maximum should not be assumed to carry over — confirm the figure for your configuration before relying on it.

What can the P1 and P2 programs store?

Two preloaded programs are provided so a stored procedure can be started with one key. The number of user-editable steps is not published within them; confirm if multi-segment programming is a requirement.

Can it be set in g rather than rpm?

Yes. Speed and RCF are both selectable and displayed, in 10 rpm and 10 ×g increments respectively.

Does the lid unlock automatically?

Automatic lid-lock release after running is published, alongside a door interlock, overspeed detector and automatic internal diagnosis. Load rotors symmetrically and never exceed a rotor’s rated speed.

Related

DM0412 Low-Speed Centrifuge — A12-10P up to 4500 rpm and 2490 ×g for 12 × 10 mL or 8 × 15 mL; A6-50P up to 4000 rpm and 1800 ×g for 6 × 50 mL or 6 × 15 mL.
Q0408E Low-Speed Centrifuge — 300–4000 rpm and 1860 ×g for 8 × 15 mL and PRP tubes, with PRP, PRF and CGF programs and 99 program memories.
D1008 Palm Micro Centrifuge — 7000 rpm and 2680 ×g for 0.2–2 mL tubes and PCR strips; the highest published maximum RCF in the range.

ALab™ is a trademark of ACS Material, LLC. Disclaimer: ACS Material, LLC believes the information on this page is accurate and represents the best and most current information available to us. Specifications reflect the current published data; final configurations are confirmed at quotation — always refer to the model datasheet for guaranteed ratings, load rotors symmetrically, never exceed a rotor's rated speed, and follow your laboratory's safety procedures for centrifuge operation. The interactive tool on this page is a schematic teaching aid, not selection software. ACS Material makes no representations or warranties, express or implied, regarding suitability for any purpose, and will not be responsible for damages resulting from use of or reliance upon this information.