ALab™ HB105-S1/S2 & HB150-S1/S2 Dry Bath Series

In stock
SKU# ALHB1500

Product Detail

ALab™ HB105-S1/S2 & HB150-S1/S2 Dry Bath Series — four digital dry baths with an LED display and an external PT1000 temperature sensor: room temperature +5 up to 105°C (HB105) or 150°C (HB150), with ±0.2°C temperature uniformity at 37°C.

ALab HB105-S1 dry bath with the transparent lid open over a four-hole heating block, two red LED displays, keys and a setting knob on the front (photo of the HB105-S1; the series page covers HB105-S1/S2 and HB150-S1/S2)
ALab™ HB105-S1/S2 & HB150-S1/S2 Dry Bath Series — image shown for reference.

The HB105-S1, HB105-S2, HB150-S1 and HB150-S2 are microprocessor controlled digital dry baths that offer control over both temperature and time, eliminating the need for an external thermometer or timer. They are used to thaw, boil, incubate and warm samples for different applications in molecular biology, assay preparation, tissue/cell culture, biochemistry, genetics, histology, clinical, environmental and industrial laboratories. Single and double heat block modules are available, the highest temperature is up to 150°C, a buzzer alerts when the time is up and an external temperature sensor PT1000 is listed. The HB105 models cover room temp+5 to 105°C and the HB150 models room temp+5 to 150°C; the S1 models are rated 100 W and the S2 models 200 W. The photo shows the HB105-S1 with its lid open; the specification table lists the models side by side.

Why choose the HB105 / HB150 series

Heat block modulesSingle and double heat block modules available.
TemperatureHighest temperature up to 150°C.
Buzzer alertBuzzer alert when the time is up.
External sensorExternal temperature sensor PT1000.
Control and displayDigital control and display of time and temperature; monitor temperature in real-time, and set timer.
Accurate and uniformAccurate and uniform temperature control; wide range of temperature control for different applications.
Heating blocksWide range of heating blocks compatible with most popular lab tubes.
Safety and cleanlinessOverheating protection ensures sample and user safety; equipped with a lid for heat preservation, and preventing pollution.
OperationUser-friendly setting knob for easy and simple operation.
Temperature range
Room temp+5 to 105°C (HB105)
Temperature range
Room temp+5 to 150°C (HB150)
Uniformity @ 37°C
±0.2°C
Display
LED
External sensor
Yes (PT1000)

Specifications General — HB105-S1, HB105-S2, HB150-S1, HB150-S2

ParameterSpecification
BrandALab™ by ACS Material
ModelHB105-S1, HB105-S2, HB150-S1, HB150-S2
SKU #ALHB1500
Temperature uniformity @ 37°C [°C]±0.2
Time setting range0min~99h59min
External sensorYes
DisplayLED
Voltage, frequency110/220V, 50/60HZ
External dimension [W×D×H]290×210×120
Weight [kg]3.2
Operating temperature [°C]10–40
Operating humidity [% RH]<80

Specifications by model HB105-S1 / S2 · HB150-S1 / S2

ParameterHB105-S1 / S2HB150-S1 / S2
Temperature range [°C]Room temp+5 to 105Room temp+5 to 150
Temperature setting range [°C]25–10525–150
Temperature control accuracy [°C]25–90: ±0.3; 90–105: ±0.625–90: ±0.3; 90–150: ±0.6
Temperature uniformity @ 37°C [°C]±0.2±0.2
Power [W]HB105-S1: 100; HB105-S2: 200HB150-S1: 100; HB150-S2: 200
Time setting range0min~99h59min0min~99h59min
External sensorYesYes
DisplayLEDLED
Voltage, frequency110/220V, 50/60HZ110/220V, 50/60HZ
External dimension [W×D×H]290×210×120290×210×120
Weight [kg]3.23.2
Operating temperature [°C]10–4010–40
Operating humidity [% RH]<80<80

Order codes one SKU per model

ModelSKU #
HB105-S1 · Room temp+5 to 105°C · 100 WALHB1100
HB105-S2 · Room temp+5 to 105°C · 200 WALHB1200
HB150-S1 · Room temp+5 to 150°C · 100 WALHB0100
HB150-S2 · Room temp+5 to 150°C · 200 WALHB0200

Parent SKU: ALHB1500. Select the model in the order menu.

Heating blocks Cat. No. as listed for HB105-S1/S2 and HB150-S1/S2

CapacityCat. No.Diameter×depth
30×0.2mL189004596.4×20mm
20×0.5mL189004607.85×28.4mm
20×1.5mL1890046111×34.7mm
20×2mL1890046211×34.7mm
12×5mL1890046316.6×46mm
12×15mL1890046416.6×73mm
4×50mL1890046529.2×73.5mm
Dual purpose block, bead bath/water bath — Adapt to S11890052295×76×56mm
Dual purpose block, bead bath/water bath — Adapt to S218900523151×95×62mm
Aluminum beads18900520—

Catalogue numbers as listed by the manufacturer for HB105-S1/S2 and HB150-S1/S2 (brochure p.65).

Where it fits

The dry bath series is small in footprint, with rapid and accurate temperature control, overheating protection and a wide range of heating blocks compatible with most popular lab tubes. It is used to thaw, boil, incubate and warm samples for different applications in molecular biology, assay preparation, tissue/cell culture, biochemistry, genetics, histology, clinical, environmental and industrial laboratories. Choose by maximum temperature: HB105-S1 / HB105-S2 room temp+5 to 105°C, HB150-S1 / HB150-S2 room temp+5 to 150°C; the S1 models are rated 100 W, the S2 models 200 W. The Heating blocks table lists the capacities and catalogue numbers, including the dual purpose blocks (bead bath / water bath) and aluminum beads.

Frequently asked questions

Which models are on this page?

HB105-S1, HB105-S2, HB150-S1 and HB150-S2. The specification table lists the HB105 and HB150 columns; select the model in the order menu.

What are the temperature range and the setting range?

Temperature range: room temp+5 to 105°C (HB105-S1/S2) and room temp+5 to 150°C (HB150-S1/S2). Temperature setting range: 25–105°C and 25–150°C. The two are listed as separate rows.

What accuracy and uniformity are published?

Temperature control accuracy: 25–90: ±0.3°C and 90–105: ±0.6°C (HB105), 25–90: ±0.3°C and 90–150: ±0.6°C (HB150). Temperature uniformity at 37°C: ±0.2°C for all four models; this value is the uniformity at 37°C, not the control accuracy.

How do the S1 and S2 models differ?

The specification table lists a power of 100 W for HB105-S1 and HB150-S1 and 200 W for HB105-S2 and HB150-S2. Single and double heat block modules are listed as available for the series.

Which heating blocks are listed?

Blocks for 30×0.2mL, 20×0.5mL, 20×1.5mL, 20×2mL, 12×5mL, 12×15mL and 4×50mL, two dual purpose blocks (bead bath / water bath) for S1 and S2, and aluminum beads, each with the catalogue number as listed in the Heating blocks table.

What time setting, display and sensor are listed?

Time setting range 0min~99h59min, an LED display and an external sensor (an external temperature sensor PT1000); a buzzer alerts when the time is up.

What are the power supply, size and weight?

Voltage and frequency 110/220V, 50/60HZ; external dimension [W×D×H] 290×210×120; weight 3.2 kg.

What operating conditions are listed?

Operating temperature 10–40°C and operating humidity <80 % RH.

ALab™ HB120-S/HB120-SC/HB60-S Dry Bath Series — HB120-S, HB120-SC and HB60-S dry baths with an LED display: up to 120°C, or five fixed temperature levels (HB60-S).
ALab™ H100-Pro Dry Bath — dry bath with a TFT display, 0–100°C setting range and programs with up to 6 sequential steps.
ALab™ Mini HCL100/Mini HC100/Mini H100 Mini Dry Bath — portable mini dry baths with an LCD display: Mini HCL100 (with hot lid), Mini HC100 and Mini H100.
ALab™ HCM100-Pro/HM100-Pro Thermo Mix — Thermo Mix with heating, cooling and mixing (HCM100-Pro) or heating and mixing (HM100-Pro), 200–1500rpm.
ALab™ HC110-Pro Thermo Control — Thermo Control with heating and cooling, −5–110°C setting range and a TFT display.
ALab™ CT4-Pro 4°C Thermostatic Ice Box — 4°C Thermostatic Ice Box with Peltier temperature control and a dual colour LED status indicator.
ALab™ is a trademark of ACS Material, LLC. Disclaimer: ACS Material, LLC believes the information on this page is accurate and represents the best and most current information available to us. Specifications reflect the current published data; final configurations are confirmed at quotation — always refer to the model datasheet for confirmed model-specific specifications, and follow your laboratory's safety procedures for dry bath operation. ACS Material makes no representations or warranties, express or implied, regarding suitability for any purpose, and will not be responsible for damages resulting from use of or reliance upon this information.