Product Detail
ALab™ HB120-S/HB120-SC/HB60-S Dry Bath Series — three low profile digital dry baths with an LED display: up to 120°C (HB120-S/SC) or five fixed temperature levels from 25 to 60°C (HB60-S).

The HB120-S, HB120-SC and HB60-S are low profile, space saving dry baths with digital control and display of time and temperature, a timer and overheating protection. The HB120-S and HB120-SC reach room temp+5 to 120°C (setting range 15–120°C) with ±0.5°C uniformity at 37°C and are rated 170 W; the HB120-SC has a temperature calibration function inbuilt for users. The HB60-S works at five discrete temperature levels (25, 30, 37, 45 and 60°C), with ±0.3°C uniformity at 37°C, is rated 160 W and carries a 5mL×30+10mL×8 dual purpose heating block. The photo shows the HB120-S/SC; the specification table lists the models side by side.
Why choose the HB120 / HB60 series
Specifications General — HB120-S, HB120-SC, HB60-S
| Parameter | Specification |
|---|---|
| Brand | ALab™ by ACS Material |
| Model | HB120-S, HB120-SC, HB60-S |
| SKU # | ALHB2000 |
| Temperature control accuracy [°C] | ±0.5 |
| Time setting range | 0min-99h59min |
| External sensor | — |
| Display | LED |
| Voltage, frequency | 110/220V, 50/60HZ |
| External dimension [W×D×H] | 175×290×85 |
| Operating temperature [°C] | 10–40 |
| Operating humidity [% RH] | <80 |
Specifications by model HB120-S / SC · HB60-S
| Parameter | HB120-S / SC | HB60-S |
|---|---|---|
| Temperature range [°C] | Room temp+5 to 120 | Room temp+5 to 60 |
| Temperature setting range [°C] | 15–120 | 5 gears: 25, 30, 37, 45, 60 |
| Temperature control accuracy [°C] | ±0.5 | ±0.5 |
| Temperature uniformity @ 37°C [°C] | ±0.5 | ±0.3 |
| Power [W] | 170 | 160 |
| Time setting range | 0min-99h59min | 0min-99h59min |
| External sensor | — | — |
| Display | LED | LED |
| Voltage, frequency | 110/220V, 50/60HZ | 110/220V, 50/60HZ |
| External dimension [W×D×H] | 175×290×85 | 175×290×85 |
| Weight [kg] | 3 | 2.5 |
| Operating temperature [°C] | 10–40 | 10–40 |
| Operating humidity [% RH] | <80 | <80 |
Order codes one SKU per model
| Model | SKU # |
|---|---|
| HB120-S · Room temp+5 to 120°C · 170 W | ALHB1S00 |
| HB120-SC · Room temp+5 to 120°C · 170 W · temperature calibration function inbuilt for users | ALHB1C00 |
| HB60-S · 5 temperature levels: 25, 30, 37, 45, 60°C · 160 W | ALHB6S00 |
Parent SKU: ALHB2000. Select the model in the order menu.
Heating blocks Cat. No. as listed for HB120-S and HB120-SC
Heating blocks for HB120-S/HB120-SC (Standard: 151×95×50mm, Thin: 151×95×36.5mm)
| Capacity | Standard | Thin | Diameter×depth |
|---|---|---|---|
| 54×0.2mL | 18900218 | 18900274 | 6.4×15mm |
| 40×0.5mL | 18900219 | 18900275 | 8.2×26.4mm |
| 40×1.5mL | 18900253 | 18900276 | 11×34.7mm |
| 40×2mL | 18900220 | 18900277 | 11×34.7mm |
| 60×2mL Ampoules | 18900818 | 18900877 | 12×37mm |
| 28×5/15mL | 18900221 | — | 17×48mm |
| 8×50mL | 18900222 | — | 29.8×48mm |
| 18+18+18 (0.2mL+0.5mL+1.5/2mL) | 18900224 | 18900278 | Each capacity |
| microplate | 18900223 | 18900279 | 127×85mm |
| 45×5mL blood collection tubes | 18900546 | — | 13.5×48mm |
| 12×0.2mL PCR 8-tube strip or 0.2mL 96 PCR Microplate | — | 18900504 | 5.7×13.2mm |
Catalogue numbers as listed by the manufacturer for HB120-S/HB120-SC (brochure p.64); an en dash means no number is printed for that block size.
Other items printed under the HB120-S/HB120-SC heading
| Capacity | Cat. No. |
|---|---|
| Two-in-one block, bead bath/water bath — Adapt to S2 | 18900523 |
| Aluminum beads | 18900520 |
Where it fits
Frequently asked questions
Which models are on this page?
HB120-S, HB120-SC and HB60-S. The specification table lists an HB120-S / SC column and an HB60-S column; select the model in the order menu.
What is the difference between HB120-S and HB120-SC?
Both share one specification column. The HB120-SC has a temperature calibration function inbuilt for users.
What are the temperature range and the setting range?
HB120-S/SC: temperature range room temp+5 to 120°C, setting range 15–120°C. HB60-S: temperature range room temp+5 to 60°C, 5 gears at 25, 30, 37, 45 and 60°C. The two are listed as separate rows.
What accuracy and uniformity are published?
Temperature control accuracy ±0.5°C for both columns. Temperature uniformity at 37°C: ±0.5°C (HB120-S/SC) and ±0.3°C (HB60-S); this value is the uniformity at 37°C, not the control accuracy.
Which heating blocks are listed?
For HB120-S/HB120-SC: blocks from 54×0.2mL up to 8×50mL, a microplate block and a 45×5mL blood collection tube block in a standard and a thin version where a number is printed, plus a two-in-one bead bath/water bath block and aluminum beads. HB60-S: 5mL×30+10mL×8 dual purpose heating block.
What power, size and weight are listed?
HB120-S/SC: 170 W, 3 kg; HB60-S: 160 W, 2.5 kg. Voltage and frequency 110/220V, 50/60HZ; external dimension [W×D×H] 175×290×85 for both.
What operating conditions are listed?
Operating temperature 10–40°C and operating humidity <80 % RH.