ALab™ HC110-Pro Thermo Control — heating and cooling with a digital TFT display: precise temperature control between -5°C and 110°C, 9 programs and interchangeable sample blocks.

ALab HC110-Pro Thermo Control seen from the front-left: a dark upper housing with a TFT display, three keys and a rotary knob, a light grey lower body, and a heating block carrying a microplate on top
ALab™ HC110-Pro Thermo Control — image shown for reference.

The HC110-Pro is a compact, programmable Thermo Control for heating and cooling with digital display, with overheating protection for safe sample handling and interchangeable sample blocks. It gives precise temperature control for heating and cooling between -5°C and 110°C for all major lab applications. The most common application includes reagent warming/cooling, DNA extractions, enzymatic reactions and reactions that need to processed at or near room temperature. The HC110-Pro has a setting range of -5–110°C, a temperature range of below room temp 25 to 110°C, 200 W, a TFT display and 9 programs; it does not mix.

Why choose the HC110-Pro

Compact and safeCompact, programmable and overheating protection for safe sample handling.
Heating and coolingPrecise temperature control for heating and cooling -5°C to 110°C for all major lab applications.
Interchangeable blocksInterchangeable sample blocks available.
ApplicationsMost common application includes reagent warming/cooling, DNA extractions, enzymatic reactions and reactions that need to processed at or near room temperature.
As low as -5°CPrecise temperature control for heating and cooling between -5°C-110°C.
Setting range
-5–110°C
Function
Heating & cooling
Control accuracy @ 20–45°C
±0.5°C
Uniformity @ 20–45°C
±0.5°C
Display
TFT
Programs
9

Specifications General — HC110-Pro

ParameterSpecification
BrandALab™ by ACS Material
ModelHC110-Pro
SKU #ALHC1O00
FunctionsHeating & cooling
Temperature range [°C]Below room temp 25 to 110
Temperature setting range [°C]-5–110
Temperature control accuracy @ 20–45 [°C]±0.5
Temperature uniformity @ 20–45 [°C]±0.5
Power [W]200
Time setting range0min~99h30min
Max. heating speed5.5°C/min
Max. cooling speed2.5°C/min (100°C to room temp); 0.5°C/min (below room temp)
Mixing speed [rpm]—
Mixing orbit [mm]—
DisplayTFT
Program9
Overheating protection [°C]150
Voltage, frequency110/220V, 50/60HZ
Dimension [mm]200×235×120
Weight [kg]7.3
Operating temperature [°C]10–40
Operating humidity [% RH]<80

Heating blocks Cat. No. as listed for HC110-Pro

CapacityMagneticMechanical fixationDiameter×depth
24×0.5mL18900401189003448.1×26mm
24×1.5mL189004021890034310.9×30.8mm
24×2mL189004031890034510.9×30.8mm
8×5mL round bottom189004041890063713.6×42mm
8×5mL cone bottom189004051890063817×51.5mm
24×1.5mL Chromatography Vial18900874—12×20.5mm
8×15mL189004061890024116.9×106mm
4×50mL189004071890024229.6×102mm
12×0.2mL PCR 8-tube strip or 0.2mL 96 PCR Microplate18900420189003495.7×13.2mm
ELISA microplate1890042318900350127×85mm
Deep well Plate18900746—127×85×42mm

Catalogue numbers as listed by the manufacturer under the heading H100-Pro/HC110-Pro/HCM100-Pro/HM100-Pro (brochure p.64): magnetic and mechanical fixation versions. An em dash means no number is printed.

Where it fits

The HC110-Pro is the heating and cooling model of the Thermo Control family: precise temperature control from -5°C to 110°C (control accuracy and uniformity at 20–45°C ±0.5°C), a TFT display, 9 programs and overheating protection at 150°C. The most common application includes reagent warming/cooling, DNA extractions, enzymatic reactions and reactions that need to processed at or near room temperature. The Heating blocks table lists the interchangeable sample blocks with magnetic and mechanical fixation catalogue numbers, diameter and depth.

Frequently asked questions

What are the temperature range and the setting range?

Temperature range: below room temp 25 to 110°C. Temperature setting range: -5–110°C. The two are listed as separate rows.

What accuracy and uniformity are published?

Temperature control accuracy at 20–45°C: ±0.5°C and temperature uniformity at 20–45°C: ±0.5°C.

How fast does it heat and cool?

Max. heating speed 5.5°C/min; max. cooling speed 2.5°C/min (100°C to room temp) and 0.5°C/min (below room temp).

Does the HC110-Pro mix?

No mixing values are listed: mixing speed and mixing orbit are given as an em dash in the specification table.

Which heating blocks are listed?

Blocks from 24×0.5mL up to 4×50mL, 12×0.2mL PCR 8-tube strip or 0.2mL 96 PCR Microplate, ELISA microplate and Deep well Plate, each with the catalogue number as listed in the Heating blocks table.

What are the power supply, size and weight?

Power 200 W; overheating protection 150°C; voltage and frequency 110/220V, 50/60HZ; dimension [mm] 200×235×120; weight 7.3 kg.

What operating conditions are listed?

Operating temperature 10–40°C and operating humidity <80 % RH.

ALab™ HB105-S1/S2 & HB150-S1/S2 Dry Bath Series — four digital dry baths with an LED display, up to 105°C (HB105) or 150°C (HB150), ±0.2°C uniformity at 37°C.
ALab™ HB120-S/HB120-SC/HB60-S Dry Bath Series — HB120-S, HB120-SC and HB60-S dry baths with an LED display: up to 120°C, or five fixed temperature levels (HB60-S).
ALab™ H100-Pro Dry Bath — dry bath with a TFT display, 0–100°C setting range and programs with up to 6 sequential steps.
ALab™ Mini HCL100/Mini HC100/Mini H100 Mini Dry Bath — portable mini dry baths with an LCD display: Mini HCL100 (with hot lid), Mini HC100 and Mini H100.
ALab™ HCM100-Pro/HM100-Pro Thermo Mix — Thermo Mix with heating, cooling and mixing (HCM100-Pro) or heating and mixing (HM100-Pro), 200–1500rpm.
ALab™ CT4-Pro 4°C Thermostatic Ice Box — 4°C Thermostatic Ice Box with Peltier temperature control and a dual colour LED status indicator.
ALab™ is a trademark of ACS Material, LLC. Disclaimer: ACS Material, LLC believes the information on this page is accurate and represents the best and most current information available to us. Specifications reflect the current published data; final configurations are confirmed at quotation — always refer to the model datasheet for confirmed model-specific specifications, and follow your laboratory's safety procedures for Thermo Control operation. ACS Material makes no representations or warranties, express or implied, regarding suitability for any purpose, and will not be responsible for damages resulting from use of or reliance upon this information.