High-Voltage Low-Frequency Digital Plasma Power Supply (CTP-2000KL)
Product Detail
Product Overview
Main Unit
![]()
Photo of CTP-2000KL Equipment
High-Voltage Low-Frequency Digital Plasma Power Supply is a DBD (Dielectric Barrier Discharge) treatment device, designed to support various types of DBD discharge electrodes. The high-voltage electrode of the DBD electrode to be used should be connected to the high-voltage interface of this equipment, while the low-voltage electrode should be connected to the low-voltage interface. After turning on the power via the circuit breaker, the voltage, current, power, frequency, and other parameters can be adjusted via the touchscreen to generate an ionized layer in the electrode. The external interface allows for voltage waveform monitoring, instantaneous current detection, and integrated current detection.
Types of Plasma Power Supply Products
|
Product Name |
High-Voltage Low-Frequency Digital Plasma Power Supply |
Modulated Pulse Low-temperature Plasma Experimental Power Supply |
Differential Output Low-temperature Plasma Experimental Power Supply |
Microsecond Pulse Low-Temperature Plasma Experimental Power Supply |
||
|
Model |
CTP-2000K |
*New CTP-2000KL |
CTP-2000K/P |
CTP-2000K/S |
CTP-2000K/A |
CTP-2000KM |
|
Output voltage (KV) |
0~30 (Customizable) |
0~30kV (Vpp) (Customizable) |
0~30 (Customizable) |
0~60 (Customizable) |
0 ~ 20 (Customizable) |
~20 (Customizable) |
|
*Center frequency(Fo) |
10 KHz (Customizable 1~100) |
Approx. 50 Hz
|
10 KHz (Customizable 1~100) |
10 KHz (Customizable 1~100) |
10 KHz (Customizable 1~100) |
10 KHz (Customizable 1~100) |
|
**DBD Discharge Gap |
Within 8mm |
- |
Within 12mm |
≤ 30 mm |
- |
Within 8mm |
|
Frequency Range |
Medium-frequency |
Low-frequency |
Medium-frequency |
Medium-frequency |
- |
- |
|
***Frequency (KHz) |
0.5 Fo~2 Fo (Adjustable) |
50-200Hz |
0.5 Fo~2 Fo (Adjustable) |
0.5 Fo~2 Fo (Adjustable) |
0.5 Fo~2 Fo (Adjustable) |
0.5 Fo~2 Fo (Adjustable) |
|
Rise Time(us) |
- |
- |
- |
- |
- |
~4 |
|
Pulse Width(μs) |
- | - | - | - | - | ~10 |
|
Fundamental Wave |
Sine wave |
- |
Modulated Pulse |
Sine wave |
Sine wave |
Modulated Pulse |
|
Output Signals |
Single high-voltage output. One connected to high voltage, one connected to ground. |
Single high-voltage output. One connected to high voltage, one connected to ground. |
Single high-voltage output. One connected to high voltage, one connected to ground. |
Dual/Two high-voltage outputs, equal amplitude, opposite phase of 180 degrees. |
Single high-voltage output. One connected to high voltage, one connected to ground. Customizable |
- |
|
Power (W) |
0~500 |
0~500 |
0~500 |
0~500 |
Power Options: Standard 0-500W Custom 1000W |
0~500 |
|
Unit Dimensions W×D×H (mm) |
250×250×360 (H) |
400×400×780(H) |
250×250×360 (H) |
250×250×380 (H) |
250 × 500 ×370 (H) |
250×250×360 (H) |
|
Weight (kg) |
8 |
58 |
9 |
12 |
25 |
9 |
|
Equipment Composition |
1.Main machine 2.Voltage Regulator |
1.Main machine Supports TCP/IP Communication Includes Control and Alarm Ports |
1.Main machine 2.Digital Pulse Modulator Panel 3.Voltage Regulator |
1.Main machine 2.Voltage Regulator |
Main machine with integrated: Voltage Regulator R16 Control Port (Customizable to TTL or others) |
1.Main machine 2.Voltage Regulator |
*~10KHz calibrated using our 50mm Diameter DBD reactor (SKU#EPDBD050). Charges may apply for customizations.
**DBD-50 only works with Models: CTP-2000K, CTP-2000K/P and CTP-2000K/L. For CTP-2000K/S, this model will require a customized DBD reactor.
**The Center frequency of 1-40 KHz has adjustable frequency range of 0.5 Fo~2 Fo; 40-70 KHz has adjustable frequency range of 0.5 Fo~1.3 Fo; Above 75 KHz has adjustable range of 0.5 Fo~1.2 Fo.
***Customizable configurations are available upon request to meet specific experimental requirements.
Applications
1. Surface modification treatment of organic and inorganic materials
- Enhance compatibility of different polymer surfaces
- Enhance suitability of biological surfaces
- Clad nanomaterials
2. Preparation of organic or inorganic nanoparticles
3. Cleaning and sterilization
Application Examples
(a) DBD Strong Discharge
(b) DBD Medium Intensity Discharge
![]()
(c) DBD Weak Discharge
(d) Vacuum Argon Discharge
(e) Vacuum Air Discharge
Photo of Plasma Discharge
Return Policy
All Plasma Power Supply models are sold as nonrefundable items. Each model includes a one-year warranty, during which we offer free maintenance services via remote support (excluding shipping costs). After the first year, remote maintenance services will be available at an additional charge, with the cost determined based on the specific circumstances and needs of the equipment.
Disclaimer: ACS Material LLC believes that the information on our website is accurate and represents the best and most current information available to us. ACS Material makes no representations or warranties either express or implied, regarding the suitability of the material for any purpose or the accuracy of the information listed here. Accordingly, ACS Material will not be responsible for damages resulting from use of or reliance upon this information.