Levon™ HP100-SA/HP100-PA Nitrogen-Filled Programmable Hotplate is a programmable hot plate with nitrogen input (0.04–0.4 MPa), a 7-inch full-color touchscreen with PLC control and an auto-lift function for proximity baking, controlling temperature from RT to 300°C with ≤±0.2°C accuracy and 0.1°C resolution. It is available in HP100-SA and HP100-PA configurations. The HP100-PA supports linear temperature control and vacuum adsorption.

Levon HP100-SA nitrogen-filled programmable hotplate with a white and black housing, a blue lid handle, a blue-framed touchscreen and front-panel controls
Levon™ HP100-SA/HP100-PA Nitrogen-Filled Programmable Hotplate (HP100-SA shown) — image shown for reference.

Temperature uniformity is ≤±1% from RT to 200°C and ≤±1.5% from 200°C to 300°C, with 0.1 s time resolution and lift pins adjustable from 0 to 30 mm. Both configurations have a hard-anodized aluminum heating plate and a height-reducible, flush-mount design, and measure 350 × 500 × 320 mm (W × D × H). The HP100-PA supports 100 recipes with up to 30 heating stages each and a settable linear heating rate of 0.5 to 10°C/min.

Why choose the HP100-SA

Hard-anodized heating plateHard-anodized aluminum heating plate with corrosion resistance.
7-inch touchscreen with PLC7-inch full-color touchscreen operation with PLC control.
Flush-mount designHeight-reducible operation with a flush-mount design.
Auto-lift for proximity bakingAuto-lift function for proximity baking mode; lift pins adjustable from 0 to 30 mm.
Nitrogen chargingNitrogen charging as an additional customization function; nitrogen input requirement 0.04–0.4 MPa.
Linear control and vacuum (HP100-PA)Linear temperature control (0.5 to 10°C/min) and vacuum adsorption on the HP100-PA.
Temperature range
RT to 300°C
Control accuracy
≤±0.2°C
Nitrogen input
0.04–0.4 MPa
Lift pin range
0–30 mm
Touchscreen
7-inch

Specifications General — HP100-SA / HP100-PA

ParameterSpecification
BrandLevon™ by ACS Material
ModelsHP100-SA / HP100-PA
SKU #LVH1SA00 (HP100-SA) / LVH1PA00 (HP100-PA)
Product TypeNitrogen-filled programmable hotplate
Temperature control rangeRT to 300°C
Temperature resolution0.1°C
Temperature control accuracy≤±0.2°C
Temperature uniformityRT to 200°C: ≤±1%; 200°C to 300°C: ≤±1.5%
Time resolution0.1 s
Lift pin adjustment range0–30 mm
Nitrogen input requirement0.04–0.4 MPa
Control7-inch full-color touchscreen, PLC control
Heating plate materialHard-anodized aluminum, corrosion-resistant
Lift functionAuto-lift function for proximity baking mode
InstallationHeight-reducible operation with flush-mount design
CustomizationAdditional customization functions, such as nitrogen charging
Dimensions [W × D × H]350 × 500 × 320 mm

Configuration comparison HP100-SA vs HP100-PA

ParameterHP100-SAHP100-PA
SKU #LVH1SA00LVH1PA00
Maximum set time999,999.9 s999,999 s
PackingCarton packagingWooden case
Warranty / quality assurance1-year product warranty1-year product quality assurance

HP100-SA additional specifications LVH1SA00

ParameterSpecification
Weight25 kg

HP100-PA additional specifications LVH1PA00

ParameterSpecification
Control functionsLinear temperature control and vacuum adsorption
Recipes100 recipes, up to 30 heating stages each
Linear heating rate0.5 to 10°C/min, settable
Lift pin useSubstrates larger than 40 mm in diameter; customizable for special requirements

Package contents

Supplied with the instrumentQty
Levon™ HP100-SA or HP100-PA main unit, as ordered1

External utilities, where required, are supplied by the user. Package contents reflect the current published configuration; the itemized bill of materials is confirmed on the quotation.

Where it fits

For programmable baking under nitrogen from RT to 300°C, with touchscreen control and auto-lift proximity baking. Choose the HP100-SA, or the HP100-PA (LVH1PA00) for linear temperature control, vacuum adsorption and 100 stored recipes. For other programmable hotplates, see the HP100; for a larger nitrogen-filled unit, see the HP200-SA. The HP100-SA is designed for compact semiconductor research.

Frequently asked questions

What functions does the HP100-PA offer?

The HP100-PA supports linear temperature control (0.5 to 10°C/min), vacuum adsorption and 100 recipes with up to 30 heating stages each. Both configurations have RT to 300°C, ≤±0.2°C accuracy, nitrogen input of 0.04–0.4 MPa and a lift pin adjustment range of 0–30 mm.

What nitrogen supply is required?

Nitrogen input requirement: 0.04–0.4 MPa (supplied by the user).

How uniform is the plate temperature?

≤±1% from RT to 200°C and ≤±1.5% from 200°C to 300°C.

What does the auto-lift function do?

Lift pins raise the substrate above the plate for proximity baking; adjustment range 0 to 30 mm.

What are the dimensions?

350 × 500 × 320 mm (W × D × H); the HP100-SA weighs 25 kg.

Levon™ HP100 Programmable Hotplate — programmable touchscreen hot plate with auto-lift, HP100-SE and HP100-PE configurations.
Levon™ HP200-SA Nitrogen-Filled Programmable Hotplate — programmable hot plate with nitrogen input, 450 × 620 × 320 mm, RT to 300°C.
Levon™ HP200 Programmable Hotplate (340 × 340 mm) — programmable touchscreen hot plate, 340 × 340 mm heating plate, RT to 300°C.
Levon™ AC200 Programmable Servo Spin Coater — servo spin coater family (AC200-S-PP / -SE / -PE / -SE-PLUS) for fragments to 8-inch wafers.
Levon™ is a trademark of ACS Material, LLC. Disclaimer: ACS Material, LLC believes the information on this page is accurate and represents the best and most current information available to us. Specifications reflect the current published data; final configurations are confirmed at quotation — always refer to the model datasheet for confirmed model-specific specifications, never exceed the rated temperature of the instrument, and follow your laboratory’s safety procedures for hot surfaces, heated substrates and the handling of resists and solvents. ACS Material makes no representations or warranties, express or implied, regarding suitability for any purpose, and will not be responsible for damages resulting from use of or reliance upon this information.