Levon™ MA200-BE Mask Aligner is a mask aligner with an exposure central wavelength of 365 nm, an 8-inch exposure area, an exposure resolution of 0.8–1.2 µm and a registration accuracy of 0.5 µm.

Levon MA200-BE mask aligner with an exposure head, microscope tubes above the stage, a dark speckled slab on round supports, a cabinet base and a swing-arm monitor and touch panel
Levon™ MA200-BE Mask Aligner — image shown for reference.

The MA200-BE has four selectable exposure modes: hard contact, soft contact, proximity and vacuum contact. The exposure irradiance is >30 mW/cm² (adjustable), the illuminance uniformity is ≤2% over a 4-inch area and ≤3% over an 8-inch area, and the exposure settings cover 0–999.9 s.

On the MA200-BE, the alignment system is an optical microscope with a high-definition CCD, with a microscope magnification of 150X–720X (adjustable). The relative travel range of the wafer to the mask is X, Y: ±5 mm and θ: ±6°. Auto-leveling and auto-focusing mechanisms are included, and the MA200-BE is equipped with wafer fragment handling capability.

The MA200-BE supports reticle sizes of 5″ × 5″, 7″ × 7″, 9″ × 9″ and a maximum allowable working thickness (design) of 0.1–3 mm (customizable fixtures supported). The unit measures 600 × 1000 × 1620 mm (W × D × H) and is packed in a paper case.

Why choose the MA200-BE

Four exposure modesHard contact, soft contact, proximity and vacuum contact exposure.
365 nm exposureExposure central wavelength of 365 nm with an exposure irradiance of >30 mW/cm² (adjustable).
Registration accuracyRegistration accuracy of 0.5 µm; relative travel range X, Y: ±5 mm and θ: ±6°.
Microscope and CCD alignmentOptical microscope with a high-definition CCD; microscope magnification of 150X–720X (adjustable).
Auto-leveling and auto-focusingAuto-leveling and auto-focusing mechanisms.
Wafer fragmentsEquipped with wafer fragment handling capability.
Wavelength
365 nm
Exposure area
8-inch
Resolution
0.8–1.2 µm
Registration accuracy
0.5 µm
Magnification
150X–720X

Specifications General — MA200-BE

ParameterSpecification
BrandLevon™ by ACS Material
ModelMA200-BE
SKU #LVMA2B00
Product TypeMask aligner
Exposure area8-inch
Supported reticle size5″ × 5″, 7″ × 7″, 9″ × 9″
Maximum allowable working thickness (design)0.1–3 mm (customizable fixtures supported)
Wafer fragmentsWafer fragment handling capability
Leveling and focusingAuto-leveling and auto-focusing mechanisms
Dimensions [W × D × H]600 × 1000 × 1620 mm
PackingPaper case
Warranty1-year product warranty

Exposure and alignment MA200-BE

ParameterSpecification
Exposure central wavelength365 nm
Exposure resolution0.8–1.2 µm
Exposure irradiance>30 mW/cm² (adjustable)
Illuminance uniformity≤2% (over 4-inch area), ≤3% (over 8-inch area)
Exposure settings0–999.9 s
Selectable exposure modesHard contact, soft contact, proximity and vacuum contact
Registration accuracy0.5 µm
Relative travel range (wafer to mask)X, Y: ±5 mm; θ: ±6°
Alignment systemOptical microscope + high-definition CCD
Microscope magnification150X–720X, adjustable

Package contents

Supplied with the instrumentQty
Levon™ MA200-BE main unit1

External utilities, where required, are supplied by the user. Package contents reflect the current published configuration; the itemized bill of materials is confirmed on the quotation.

Where it fits

For laboratory mask alignment and exposure at 365 nm within an 8-inch exposure area, in hard contact, soft contact, proximity or vacuum contact mode, with reticles of 5″ × 5″, 7″ × 7″ or 9″ × 9″ and a design working thickness range of 0.1–3 mm (customizable fixtures supported). For vapor deposition on substrates up to 150 × 150 mm, see the VCD.

Frequently asked questions

Which exposure modes are available?

Hard contact, soft contact, proximity and vacuum contact.

What are the exposure specifications?

Exposure central wavelength 365 nm, exposure resolution 0.8–1.2 µm, exposure irradiance >30 mW/cm² (adjustable), illuminance uniformity ≤2% over a 4-inch area and ≤3% over an 8-inch area, exposure settings 0–999.9 s, exposure area 8-inch.

How is alignment done?

With an optical microscope and a high-definition CCD (magnification 150X–720X, adjustable); the registration accuracy is 0.5 µm and the relative travel range of the wafer to the mask is X, Y: ±5 mm and θ: ±6°.

Which masks and substrates fit?

Supported reticle sizes are 5″ × 5″, 7″ × 7″, 9″ × 9″; the maximum allowable working thickness (design) is 0.1–3 mm (customizable fixtures supported), and wafer fragments can be handled.

How large is the unit?

600 × 1000 × 1620 mm (W × D × H); it is packed in a paper case.

Levon™ VCD Vapor Deposition System — vapor deposition system for substrates up to 150 × 150 mm, 6 mm substrate chamber, ultimate pressure <0.5 Pa.
Levon™ AC200 Programmable Servo Spin Coater — servo spin coater family (AC200-S-PP / -SE / -PE / -SE-PLUS) for fragments to 8-inch wafers.
Levon™ HP100 Programmable Hotplate — programmable touchscreen hot plate with auto-lift, HP100-SE and HP100-PE configurations.
Levon™ is a trademark of ACS Material, LLC. Disclaimer: ACS Material, LLC believes the information on this page is accurate and represents the best and most current information available to us. Specifications reflect the current published data; final configurations are confirmed at quotation — always refer to the model datasheet for confirmed model-specific specifications, operate the instrument within its rated power, temperature and gas-supply limits, and follow your laboratory’s safety procedures for UV light sources, vacuum, heated surfaces, moving parts and electrical equipment. ACS Material makes no representations or warranties, express or implied, regarding suitability for any purpose, and will not be responsible for damages resulting from use of or reliance upon this information.