GEt Quote

ALab™ MS10-H500-Pro LCD Digital Magnetic Hotplate Stirrer

In stock
SKU# ALM10H

Product Detail

The ALab™ MS10-H500-Pro LCD Digital Magnetic Hotplate Stirrer from ACS Material pairs a 254 × 254 mm (10 inch) glass ceramic work plate with digital heating to a 500 °C plate limit in 1 °C increments and brushless DC stirring from 100 to 1500 rpm at ±1 rpm resolution. It stirs up to 30 L of water. Speed and temperature share one LCD, an external PT1000 input lets you control the medium rather than the plate, the timer runs from 1 minute to 99 h 59 min, and an SD card records running data in real time.

ACS Material ALab MS10-H500-Pro digital magnetic hotplate stirrer, white housing with 10 inch glass ceramic plate, LCD display and TEMP and SPEED control knobs
ACS Material ALab™ MS10-H500-Pro — 254 × 254 mm glass ceramic plate, 500 °C plate limit, 100–1500 rpm, 30 L water capacity

Why choose the MS10-H500-Pro

30 L of water on a 10-inch plateA 254 × 254 mm glass ceramic work top and a brushless DC motor rated at 10 W handle batches up to 30 L of water, with magnetic bars up to 80 mm long. This is the large-format unit in our ALab magnetic stirring range.
500 °C plate limit on glass ceramicHeat from room temperature to 500 °C in 1 °C increments, with overheating protection at 540 °C. The glass ceramic top resists chemical attack and transfers heat efficiently.
Control the medium, not the plateConnect an external PT1000 sensor and the instrument regulates on your liquid instead of the work plate. Sensor accuracy is ±0.2 °C; plate temperature control is ±1 °C below 100 °C and ±1% above 100 °C.
Timer and SD-card recordingSet a run from 1 minute to 99 h 59 min and walk away from the stopwatch. The SD card data connector records the instrument’s running data in real time.
Work Plate
254 × 254 mm
Plate Temp. Limit
500 °C
Max. Stirring [H2O]
30 L

Product specifications

ALab™ MS10-H500-Pro technical specifications, supplied by ACS Material.
ParameterMS10-H500-Pro
BrandALab™ by ACS Material
ACS SKU #ALM10H5P
Work Plate Dimension [W × D]254 × 254 mm (10 inch)
Work Plate MaterialGlass ceramic
Motor TypeBrushless DC motor
Motor Rating Output10 W
Stirring Positions1
Max. Stirring Quantity [H2O]30 L
Max. Magnetic Bar [length]80 mm
Speed Range100–1500 rpm
Speed Resolution±1 rpm
Speed DisplayLCD
Heating Temperature RangeRoom temp. – 500 °C, increment 1 °C
Temperature DisplayLCD
Temperature Control Accuracy±1 °C (<100 °C) · ±1% (>100 °C)
Temperature Display Accuracy±0.1 °C
Overheating Protection540 °C
External Temperature SensorPT1000 · sensor accuracy ±0.2 °C
“Hot” Warning50 °C
Timer Function1 min – 99 h 59 min
Data ConnectorSD card
Protection ClassIP20
Power1700 W total · 1500 W heating output
Voltage, Frequency100–120 / 200–240 V, 50/60 Hz
Dimensions [W×D×H]328 × 424 × 138 mm
Weight7.2 kg
Permissible Ambient Conditions5–40 °C, 80% RH

Configuration

The MS10-H500-Pro accepts an external PT1000 temperature sensor for control on the medium. Your approved ACS Material quotation specifies the sensor model, support accessories, quantities, stir-bar inclusion and the cord and electrical configuration supplied with your order. Please let us know how you intend to use the instrument and we will quote the right configuration.

The instrument runs on 100–120 or 200–240 V at 50/60 Hz; the cord supplied depends on the order. Stir bars are quoted separately unless your quotation lists them.

Where it fits in the ALab range

This is our large-format hotplate stirrer. Choose the MS10-H500-Pro when vessel size, batch volume, timed running or recorded run data matter: a 10-inch plate, 30 L of water, a settable timer and SD-card recording. If your bench is tighter or your batches are smaller, please contact us about the rest of the ALab magnetic stirring range and we will match the plate size and capacity to the work space.

FAQ

Is 500 °C the plate temperature or my sample temperature?

It is the work plate. We rate the instrument from room temperature to 500 °C at the plate, set in 1 °C increments, with overheating protection at 540 °C. What your sample reaches depends on the vessel, the volume, the medium and the losses in your setup, so we do not quote a sample temperature. Where the temperature of the liquid is what matters, use an external PT1000 sensor and let the instrument regulate on that instead.

What does the PT1000 input do for me?

It moves the control point from the plate into your medium. We rate the external sensor at ±0.2 °C. Without it the instrument regulates plate temperature, rated at ±1 °C below 100 °C and ±1% above 100 °C. Sensor model and supply are set by your quotation.

What do the four accuracy figures mean?

They describe four different things and are not interchangeable. Speed resolution ±1 rpm is the increment the speed is set and shown in. Temperature control accuracy ±1 °C below 100 °C and ±1% above is how closely the instrument holds the plate to setpoint. Temperature display accuracy ±0.1 °C is the readout resolution. External sensor accuracy ±0.2 °C applies to the PT1000 probe. Please read them separately when you compare instruments.

Can it stir 30 litres?

We rate the maximum stirring quantity at 30 L for water, with a magnetic bar up to 80 mm long. We do not publish a capacity for other media, because viscosity, vessel geometry, bar length and fill depth all affect what couples reliably. Size against your own medium rather than against the water figure, and please contact us if you are unsure.

What does the SD card record?

The data connector records the instrument’s running data to an SD card in real time. We do not specify the file format, logging interval or supported card capacity on this page — please contact us before you build the feature into a regulated workflow and we will confirm what your unit does.

What does the “HOT” warning indicate?

It flashes whenever the work plate is above 50 °C, including after you switch the hotplate off. Treat the plate as hot until it clears, and follow the operating manual and your laboratory’s own procedures for residual heat.

What protection class is it?

IP20. Under IEC 60529 the first digit describes protection against solid foreign objects and the second describes protection against water. Site the instrument, clean it and handle spills according to the operating manual and your laboratory’s procedures.

Related

ALab™ MS-H380-Pro — magnetic hotplate stirrer
ALab™ MS7-H280-G — magnetic hotplate stirrer
ALab™ DMS7-550M — magnetic hotplate stirrer
ALab™ EcoStir — magnetic stirrer

Related models are listed by name and category only. Contact us for their specifications, or see their own product pages.

ALab™ is a trademark of ACS Material, LLC. Disclaimer: ACS Material, LLC believes the information on this page is accurate and represents the best and most current information available to us. Specifications are typical and may vary; your approved ACS Material quotation states the ratings and configuration supplied with your order. We rate the maximum stirring quantity for water and do not specify a capacity for other media. Hotplates reach surface temperatures capable of causing burns and of igniting flammable vapours; verify chemical compatibility for your application and follow the operating manual and your laboratory’s safety procedures for heated stirring. ACS Material makes no representations or warranties, express or implied, regarding suitability for any purpose, and will not be responsible for damages resulting from use of or reliance upon this information.