ALab™ QPette Mechanical Pipette
Product Detail
ALab™ QPette — a mechanical pipette in adjustable single-channel and fixed volume versions: light weight, ergonomic, low force design with a digital display, covering 0.1 µL to 10 mL.

The QPette mechanical pipettes are light weight, ergonomic and low force in design, with a digital display that clearly reads the volume setting. The pipettes cover a volume range of 0.1 µL to 10 mL and are easy to calibrate and maintain with the tool supplied; the design helps avoid repetitive strain injuries. They are calibrated in accordance with ISO8655 and each pipette is supplied with an individual test certificate; the lower section can be autoclaved. The volume is selected by simply turning the plunger button; a comfortable finger support and a tip ejector that allows convenient one-handed operation are provided, the ejector collar and tip cone can be removed, and the durable tip cone materials provide excellent chemical resistance. The specification tables below list the volume range, increment, test volume, systematic error and random error of the single-channel adjustable and fixed volume pipettes.
Why choose the QPette
Specifications General — QPette
| Parameter | Specification |
|---|---|
| Brand | ALab™ by ACS Material |
| Model | QPette |
| SKU # | ALQPEE00 |
| Product Type | Mechanical Pipette |
| Single-channel adjustable | Nine volume ranges, 0.1–10000 μL |
| Fixed volume | Nine volumes, 5–1000 μL |
| Display | Digital display |
| Sterilization | The lower section can be autoclaved |
| Calibration | In accordance with ISO8655; each pipette supplied with individual test certificate |
Volume range and accuracy single-channel adjustable · fixed volume
Single-channel Adjustable Volume Pipettes
| Volume range (µL) | Increment (µL) | Test volume (µL) | Systematic error (µL) | Systematic error (%) | Random error (µL) | Random error (%) |
|---|---|---|---|---|---|---|
| 0.1–2.5 | 0.05 | 2.5 1.25 0.25 | ±0.0625 ±0.0375 ±0.03 | ±2.50 ±3.00 ±12.00 | ±0.05 ±0.0375 ±0.015 | ±2.00 ±3.00 ±6.00 |
| 0.5–10 | 0.1 | 10 5 1 | ±0.1 ±0.075 ±0.025 | ±1.00 ±1.50 ±2.50 | ±0.08 ±0.075 ±0.015 | ±0.80 ±1.50 ±1.50 |
| 2–20 | 0.5 | 20 10 2 | ±0.18 ±0.12 ±0.06 | ±0.90 ±1.20 ±3.00 | ±0.08 ±0.1 ±0.04 | ±0.04 ±1.00 ±2.00 |
| 5–50 | 0.5 | 50 25 5 | ±0.3 ±0.225 ±0.1 | ±0.60 ±0.90 ±2.00 | ±0.15 ±0.15 ±0.1 | ±0.30 ±0.60 ±2.00 |
| 10–100 | 1 | 100 50 10 | ±0.8 ±0.5 ±0.3 | ±0.80 ±1.00 ±3.00 | ±0.15 ±0.2 ±0.15 | ±0.15 ±0.40 ±1.50 |
| 20–200 | 1 | 200 100 20 | ±1.2 ±0.8 ±0.6 | ±0.60 ±0.80 ±3.00 | ±0.3 ±0.3 ±0.2 | ±0.15 ±0.30 ±1.00 |
| 100–1000 | 5 | 1000 500 100 | ±6 ±3.5 ±2 | ±0.60 ±0.70 ±2.00 | ±2 ±1.25 ±0.7 | ±0.20 ±0.25 ±0.70 |
| 500–5000 | 50 | 5000 2500 500 | ±25 ±15 ±3.5 | ±0.50 ±0.60 ±0.70 | ±7.5 ±7.5 ±1.5 | ±0.15 ±0.30 ±0.30 |
| 1000–10000 | 100 | 10000 5000 1000 | ±60 ±60 ±30 | ±0.60 ±1.20 ±3.00 | ±20 ±15 ±6 | ±0.20 ±0.30 ±0.60 |
Fixed Volume Pipettes
| Volume range (µL) | Increment (µL) | Test volume (µL) | Systematic error (µL) | Systematic error (%) | Random error (µL) | Random error (%) |
|---|---|---|---|---|---|---|
| 5 | - | 5 | ±0.065 | ±1.3 | ±0.06 | ±1.2 |
| 10 | - | 10 | ±0.08 | ±0.8 | ±0.08 | ±0.8 |
| 20 | - | 20 | ±0.12 | ±0.6 | ±0.1 | ±0.5 |
| 25 | - | 25 | ±0.125 | ±0.5 | ±0.075 | ±0.3 |
| 50 | - | 50 | ±0.25 | ±0.5 | ±0.15 | ±0.3 |
| 100 | - | 100 | ±0.5 | ±0.5 | ±0.3 | ±0.3 |
| 200 | - | 200 | ±0.8 | ±0.4 | ±0.4 | ±0.2 |
| 500 | - | 500 | ±1.5 | ±0.3 | ±1.0 | ±0.2 |
| 1000 | - | 1000 | ±3.0 | ±0.3 | ±2.0 | ±0.2 |
Order codes one SKU per configuration
| Configuration | SKU # |
|---|---|
| Single-channel adjustable · 0.1–2.5 μL | ALQPEE01 |
| Single-channel adjustable · 0.5–10 μL | ALQPEE02 |
| Single-channel adjustable · 2–20 μL | ALQPEE03 |
| Single-channel adjustable · 5–50 μL | ALQPEE04 |
| Single-channel adjustable · 10–100 μL | ALQPEE05 |
| Single-channel adjustable · 20–200 μL | ALQPEE06 |
| Single-channel adjustable · 100–1000 μL | ALQPEE07 |
| Single-channel adjustable · 500–5000 μL | ALQPEE08 |
| Single-channel adjustable · 1000–10000 μL | ALQPEE09 |
| Fixed volume · 5 μL | ALQPEE10 |
| Fixed volume · 10 μL | ALQPEE11 |
| Fixed volume · 20 μL | ALQPEE12 |
| Fixed volume · 25 μL | ALQPEE13 |
| Fixed volume · 50 μL | ALQPEE14 |
| Fixed volume · 100 μL | ALQPEE15 |
| Fixed volume · 200 μL | ALQPEE16 |
| Fixed volume · 500 μL | ALQPEE17 |
| Fixed volume · 1000 μL | ALQPEE18 |
Parent SKU: ALQPEE00. Select the configuration in the order menu.
Package contents
| Supplied with the instrument | Qty |
|---|---|
| ALab™ QPette (configuration and volume range as selected) | 1 |
Package contents reflect the current published configuration; the itemized bill of materials is confirmed on the quotation.
Where it fits
Frequently asked questions
Which configurations are available?
Adjustable single-channel pipettes (nine ranges, 0.1–2.5 to 1000–10000 µL) and fixed volume pipettes (nine volumes, 5 to 1000 µL).
Can the QPette be autoclaved?
The lower section can be autoclaved.
Are the pipettes calibrated?
Yes. They are calibrated in accordance with ISO8655 and each pipette is supplied with an individual test certificate. They are easy to calibrate and maintain with the tool supplied.
How is the volume set on adjustable-volume models?
Simply turn the plunger button for volume selection; the digital display clearly reads the volume setting.
How is the tip ejected?
The tip ejector allows convenient one-handed operation. The ejector collar and tip cone can be removed.
What are the error limits of the 0.5–10 µL range?
Increment 0.1 µL. At 10, 5 and 1 µL test volume the systematic error is ±0.1, ±0.075 and ±0.025 µL (±1.00, ±1.50 and ±2.50 %) and the random error ±0.08, ±0.075 and ±0.015 µL (±0.80, ±1.50 and ±1.50 %).
Which SKU belongs to which configuration?
Each fixed volume and each adjustable volume range has its own SKU; see the order codes table.