GEt Quote

PressPro™ X-Ray Fluorescence Press Machine (EPFM Series)

In stock
SKU# EPFM

X-Ray Fluorescence Press Machine

Product Detail

PressPro™ X-Ray Fluorescence Press Machine (EPFM series) prepares samples for X-ray fluorescence (XRF) analyzers. Four models cover 30 T / 40 T with manual (EPFM) or automatic (EPFA) pressurization, and include one set of XRF sample-preparation dies (boric acid, steel ring, plastic ring, or aluminum cup).

PressPro EPFM series X-ray fluorescence press machine, automatic model with touch screen
PressPro™ X-Ray Fluorescence Press Machine (EPFM Series) — Representative Configuration (Automatic Model). Image shown for reference; manual and automatic configurations vary by model.

Why choose the EPFM series

XRF sample preparationDesigned for preparing samples for X-ray fluorescence analyzers; with specific molds, one machine serves multiple purposes.
Manual & automatic modelsEPFM30TX / EPFM40TX with manual pressurization; EPFA30TX / EPFA40TX with automatic pressurization, pressure holding, and pressure compensation.
30T / 40T capacity0‑30T (31.5 MPa) or 0‑40T (30 MPa) for manual models; automatic models with real-time sample pressure calculation.
XRF sample-preparation diesOne set included as standard — boric acid, steel ring, plastic ring, or aluminum cup (select one).
Automatic safety & data (EPFA)Limit‑switch pressure relief, overpressure protection, and USB data export on automatic models.
Wide R&D applicationSuperconductors, batteries, rare earths, catalysts, cement, minerals, marine mud, powder metallurgy, and advanced ceramics.
Pressure Range
30 / 40 T
XRF Molds
Boric acid / Steel / Plastic / Al cup
Operation
Manual / Automatic

Specifications General — all models

ParameterSpecification
BrandPressPro™ by ACS Material
Product NamePressPro™ X-Ray Fluorescence Press Machine
Series (Parent SKU)EPFM
Models (SKU)EPFM30TX · EPFM40TX · EPFA30TX · EPFA40TX
ApplicationSample preparation for X-ray fluorescence (XRF) analyzers
Pressurization MethodManual (EPFM) / automatic (EPFA)
Standard MoldOne set of XRF sample-preparation dies (boric acid, steel ring, plastic ring, or aluminum cup — select one)
ConfigurationOne main machine with one set of XRF sample-preparation dies

Model comparison

ParameterEPFM30TXEPFM40TXEPFA30TXEPFA40TX
Pressure Range0‑30T / 31.5MPa0‑40T / 30MPa0.3‑30T / 0.1t0.4‑40T / 0.1t
Pressure Conversion1MPa = 0.95t1MPa = 1.33tAutomaticAutomatic
Piston DiameterØ110mmØ130mmØ110mmØ130mm
Max Piston Stroke<30mm<50mm<30mm<50mm
Pressure Gauge TypePointer gauge with dual scales in t and MPa (digital gauge optional)7‑inch touch LCD screen (remote control optional)
Pressurization MethodManual pressurization / gradual pressurization, manual pressure releaseAutomatic pressurization / holding / compensation, pressure release
Pressure Holding TimeManual controlUnlimited (N seconds)
Sample Pressure Conversion/Real‑time automatic calculation of sample pressure (MPa)
Hydraulic Cylinder Limit ProtectionWarning: do not exceed the cylinder rising heightAutomatic pressure relief when cylinder touches limit switch
System Safety Configuration/Automatic pressure relief when system pressure exceeds safe value
Safety ConfigurationBulletproof glass shield (optional)Bulletproof glass protection door, leakage protection, emergency stop switch
Data Management/Storage, management, viewing, USB output
Power Supply/220V (50Hz/60Hz)
Worktable DiameterØ128mmØ148mmØ128mmØ148mm
WorkspaceW: 92×160mmW: 106×180mmW: 145×160mmW: 165×180mm
Overall Dimensions275×210×440mm295×230×490mm230×405×470mm260×430×500mm
Approx. Weight58 kg78 kg85 kg120 kg

Package contents

Supplied with the instrumentQty
EPFM / EPFA series main machine (X‑ray fluorescence press machine)1
One set of XRF sample‑preparation dies — boric acid, steel ring, plastic ring, or aluminum cup (select one)1

Bulletproof glass shield and digital pressure gauge (EPFM manual models); remote control (EPFA automatic models) are optional and not included. Package contents reflect the current published configuration; the itemized bill of materials is confirmed on the quotation.

Where it fits

For X-ray fluorescence (XRF) sample preparation: select the manual (EPFM30TX / EPFM40TX) or automatic (EPFA30TX / EPFA40TX) model, and the XRF sample-preparation die type (boric acid, steel ring, plastic ring, or aluminum cup) to match the sample. The automatic models provide real‑time sample pressure calculation, pressure holding, and USB data export.

Frequently asked questions

What is the difference between the four models?

Pressurization mode and capacity. EPFM30TX and EPFM40TX use manual hydraulic pressurization with a pointer gauge; EPFA30TX and EPFA40TX use automatic pressurization with a 7‑inch touch LCD screen. The 30T models and 40T models differ in piston diameter, stroke, worktable size, and overall dimensions as listed in the table.

Which molds are included?

One set of XRF sample-preparation dies is included as standard — select boric acid, steel ring, plastic ring, or aluminum cup.

What is the pressure range?

EPFM30TX: 0‑30T / 31.5 MPa (1 MPa = 0.95 t); EPFM40TX: 0‑40T / 30 MPa (1 MPa = 1.33 t). The automatic models (EPFA30TX / EPFA40TX) calculate sample pressure automatically in real time.

Do the automatic models need a power supply?

Yes. The EPFA automatic models require 220V (50Hz/60Hz). The EPFM manual models are manually operated.

What safety features do the automatic models have?

Automatic pressure relief when the cylinder touches the limit switch, automatic relief on system overpressure, bulletproof glass protection door, leakage protection, and an emergency stop switch.

PressPro™ Protective Small Tonnage Powder Press Machine (EPPM series) — manual hydraulic powder press for lab sample preparation.
PressPro™ Automatic Powder Press Machine (EPPA series) — automatic powder pressing with programmable control.
PressPro™ Battery Material Slicing Machine (EPBBMQ10) — manual punching of battery separators and electrodes.
PressPro™ is a trademark of ACS Material, LLC. Disclaimer: ACS Material, LLC believes the information on this page is accurate and represents the best and most current information available to us. Specifications reflect the current published data; final configurations are confirmed at quotation — always refer to the model datasheet for confirmed model-specific specifications, never exceed the rated pressure, and follow your laboratory's safety procedures for press operation. ACS Material makes no representations or warranties, express or implied, regarding suitability for any purpose, and will not be responsible for damages resulting from use of or reliance upon this information.