Specimens cut from one compression-molded plaque share a molding-run record, but their positions, orientations and subsequent handling can differ. This guide sets out a specimen record plan for plaques in three layers, the material lineage, the plaque history and the specimen map, and reports how two Polytevo Series by ACS Material presses differ in what can be set. It is a record plan, not a hot-pressing tutorial.

1. The short answer: three layers of record for one plaque
This record plan has three layers that help trace specimen preparation and assess comparability; completing the record does not by itself establish comparable specimens.
- Material lineage. What the compound was and what happened to it before it reached the press: identity, lot, compounding step, drying.
- Plaque history. What the press did: the route and machine, the mold or frame, the temperature, pressure, time and degassing as run, the cooling and the release.
- Specimen map. Where on the plaque each specimen was cut or punched, in what orientation, and which test it went to.
Section 2 explains why each layer matters, using two test method references and several studies. Section 3 gives the record plan as a table, section 4 reports how the Polytevo plate vulcanizing press and the Polytevo vacuum plate vulcanizing press differ in what can be set, section 5 points to guides on this site that cover the press cycle itself, and section 6 says what the record leaves to other guides. The cluster entry point, Molding Plastic Test Specimens: Injection, Transfer, Compression, places compression molding beside the other two routes, and Transfer Molding vs Injection Molding for Small Specimen Batches covers the handoff record for the molded routes.
2. Why a plaque needs a record
Test method reference: ISO 293:2023 covers preparation of thermoplastic specimens and sheets and excludes reinforced thermoplastics. Its scope identifies standardized cooling methods and material-specific selection of molding temperature and cooling method.1 Test method reference: ASTM D4703-24 covers compression molding of thermoplastics into specimens, plaques or sheets and differs in detail from the cited ISO document.2 Record the applicable document, edition and departures.
Cooling is part of the plaque, not an afterthought. Kawamoto and co-workers reported different dynamic mechanical behaviour in compression-molded polypropylene sheets with similar bulk crystallinity but different surface crystallinity.3 A related effect appears in injection molding: unequal temperatures on the two mold surfaces changed the morphology and the distribution of modulus through the thickness of polypropylene samples.4 These material-specific observations motivate retaining preparation and location records; they do not prescribe a platen-temperature or cooling program.
The history before the press is the second layer. Moisture changed the yield stress and time-to-failure of injection-molded polyamide 6,5 and polylactide extruded five times lost up to 30 percent of its molecular weight when it was not dried.6 In small-scale melt mixing of carbon nanotubes in polyamides, temperature, rotation speed and mixing time changed the dispersion and the electrical resistivity.7 None of these was a compression-molding study. These studies concern particular compounding, reprocessing or specimen-conditioning conditions, not compression-molding recipes. As a recordkeeping recommendation, retain the actual compounding history, drying when performed, and subsequent storage and conditioning.
Compression molding of polymers and composites has chapter-length treatments in the molding literature.8 The route also differs from injection molding in what it leaves in the material: injection-molded polypropylene bars changed their skin, intermediate and core layers with melt temperature and injection pressure,9 but this guide cites no study that compares compression-molded plaques with injection-molded bars of the same compound, so whether the two give the same results is a question to answer by testing.
3. The record plan
The table sets out the three layers as fields. It is guidance from this guide, drawn from the studies above, not a published checklist.
| Layer | Field | What to write |
|---|---|---|
| Material lineage | Identity | Material, grade, lot, filler or additive content, and the compound batch number |
| Material lineage | Compounding step | Machine, temperature, speed and time or throughput, and date |
| Material lineage | Moisture history | Any drying procedure, and subsequent storage or conditioning |
| Plaque history | Document followed | The test method reference, its year, and any departure from it |
| Plaque history | Press and mold | Machine, plate or mold size, frame or mold used, release films |
| Plaque history | Cycle as run | Temperature, pressure, time and number of degassing cycles as set and as displayed, with their units |
| Plaque history | Atmosphere | Ambient or vacuum, and the vacuum setting if used |
| Plaque history | Cooling and release | Cooling method, whether under load, and when the plaque was released |
| Plaque history | Plaque check | Thickness at several points, visible defects, and a sketch of the plaque |
| Specimen map | Cut plan | Position and orientation of each specimen on the plaque, and the order of cutting |
| Specimen map | Identification | A specimen number that links to the plaque number and the map |
| Specimen map | Intended test | The test and the test method reference the specimen is for, by name only |
The fields are a working list from this guide. Which of them a method requires is stated in the method itself.
Assign a plaque identifier and maintain a planned and as-cut specimen map linking each specimen to its position and orientation. Use an identification method that does not alter the intended test regions, and record changes as the work proceeds.
4. How the two Polytevo presses differ in setup
This section reports what the pages say on 15 November 2026, and no literature appears in it. Each figure keeps the page’s label and unit. Specifications are as published on each page, and final configurations are confirmed on quotation.
The Polytevo Series Plate Vulcanizing Press Machine page describes a PLC-controlled platen press for the compression molding of test specimens, offered as the ACS-7006A-30 (30 T) and the ACS-7006A-50 (50 T). It says the machines form the material in a mold between the heating plates under controlled pressure and temperature, and that the pressure, temperature, time and frequency of the process can be set on a color touch-screen PLC.
The Polytevo Series Vacuum Plate Vulcanizing Press page describes the ACS-7006ZGI as a PLC program-controlled 30 T laboratory press with a fully enclosed vacuum hood. It says that the plate pressure, vacuum pressure, temperature, time and number of degassing cycles can be set, and that the raw material is placed in a mold between the electrically heated plates and pressed at the rated temperature to form material for testing.
| Page label | Plate Vulcanizing Press Machine (ACS-7006A-30 / ACS-7006A-50) | Vacuum Plate Vulcanizing Press (ACS-7006ZGI) |
|---|---|---|
| Settable on the PLC | Pressure, temperature, time and frequency; temperature and time on the touch panel | Plate pressure, vacuum pressure, temperature, time and number of degassing cycles |
| Degassing cycles | Exhaust (degassing) cycles 0–99 times | Number of degassing cycles 0–999 cycles, settable |
| Product type and vacuum | Vulcanizing platen press machine | Laboratory vacuum plate vulcanizing press; vacuum degree 0 to −0.08 MPa |
| Working space and cooling | Double space: upper space heating, lower space cooling | Cooling method: tap-water cooling |
| Temperature | RT to 300°C; accuracy ±2°C | Temperature range RT to 300°C; control precision ±2°C |
| Capacity and plates | 30 T with 300 × 300 mm plates; 50 T with 400 × 400 mm plates | 30 T; two 300 × 300 mm plates |
| Pressure accuracy | ±10% | Pressure control precision ±10% |
The table preserves the labels used on the two press pages; it does not prescribe a plaque-processing cycle.
Record the displayed quantity with its label and unit. Hydraulic pressure, applied force and specimen contact stress are not interchangeable. Confirm what the displayed quantity represents before interpreting it as stress on the plaque. This guide does not turn the machine figures into a stress on the plaque. Ask on the quotation what area or quantity the displayed pressure refers to.
The double working space of the first press and the vacuum hood of the second raise setup questions that the pages leave to the quotation. For the first, ask how the mold is moved between the heating space and the cooling space, and where in the cycle the cooling is recorded. For the second, ask how the vacuum is applied during the cycle and at which step the degassing cycles occur.
5. What the other guides on this site cover
The press cycle itself is covered in guides already published on this site, which this record plan points to rather than repeats. The Laboratory Hot Pressing Guide: Equipment, Variables and Limits covers the equipment and variables of hot pressing. Vacuum vs Ambient Hot Pressing: Air, Moisture and Trapped Gas covers the choice of atmosphere. Pressure Stages and Temperature Programs in Hot Pressing covers the pressure and temperature segments of a cycle, and its section on what to record lists the cycle segments, so write those segments into the “cycle as run” field above. Tonnage-to-MPa Calculator for Pellet Pressing converts a press load into a pressure on a pellet die, which is a different arrangement from a plaque mold.
Those guides were written around other presses on this site. Use them for the method, and use the Polytevo pages for Polytevo figures.
6. What this record does not do
The record names the test a specimen is for, and it stops there. How the specimen is conditioned, loaded and read is the business of the test method, and no result of any test is read or interpreted in this guide. This record plan prescribes no processing settings. Select preparation conditions from the applicable material specification and preparation method; the cited ISO scope specifically addresses selection of molding temperature and cooling method.1
7. FAQ
What should a compression-molded plaque record contain?
Three layers: the material lineage (identity, compounding, drying), the plaque history (document followed, press and mold, cycle as run, atmosphere, cooling and release) and the specimen map (cut plan, specimen numbers and intended test). Section 3 lists the fields; it is guidance, not a published checklist.
Which standards cover compression molding of thermoplastic test specimens?
Test method reference: ISO 293:2023 covers preparation of thermoplastic specimens and sheets and excludes reinforced thermoplastics. Test method reference: ASTM D4703-24 covers compression molding of thermoplastics into specimens, plaques or sheets and differs in detail from the cited ISO document. The cited ASTM practice states that it is no longer equivalent to the cited ISO method, so a record should name the one followed.1,2
Why does the cooling method belong in the record?
The cited ISO method standardizes eight different cooling methods, and a study of compression-molded polypropylene sheets found that sheets with similar bulk crystallinity but different surface crystallinity had different dynamic mechanical properties.1,3 The cooling method and the release step are therefore worth writing down.
What can be set on the two Polytevo presses?
The plate vulcanizing press page lists pressure, temperature, time and frequency, with exhaust (degassing) cycles of 0–99. The vacuum press page lists plate pressure, vacuum pressure, temperature, time and the number of degassing cycles, 0–999. Specifications are as published on each page and final configurations are confirmed on quotation.
Does this guide explain how to run a hot press?
No. The press cycle is covered in the guides listed in section 5, and this guide only says what to write down beside the plaque and how the two Polytevo presses differ in what can be set.
8. Keep exploring the Lab-Scale Polymer Processing Knowledge Hub
This guide belongs to the molding-specimens cluster of the Lab-Scale Polymer Processing and Testing: A Workflow Guide, which places every machine of the Polytevo Series by ACS Material in the stage of the lab route where it is used. The cluster starts at Molding Plastic Test Specimens: Injection, Transfer, Compression; related guides:
- Molding Plastic Test Specimens: Injection, Transfer, Compression. Entry guide to the cluster: a route map from compound to specimen, by what the specimen has to represent.
- Transfer Molding vs Injection Molding for Small Specimen Batches. Two ways to mold a small compounded batch, and the record that travels with the specimens.
To discuss a configuration, describe the material and its form, the specimen types and the number of specimens you need, the utilities available in your laboratory, and the mold or plate size you plan to use, then send it through Request a Quote. Specifications are as published on each product page, and final configurations are confirmed on quotation.