  • Lab Equipment List for a New Research Lab: Benchtop Essentials by Lab Type

    Oct 27, 2026 | ACS MATERIAL LLC

    A useful lab equipment list starts with how a sample moves across the bench, not with a catalog. In most research labs a sample is measured out, mixed or heated, separated, measured again, and kept at a set temperature along the way. This guide follows that path step by step. It explains what each class of benchtop instrument does and which specifications matter when you choose one. It ends with editorial checklists for four common lab types, each item marked Essential, Common or Can wait.

    Quick answer: For most new research labs, the core benchtop equipment list has five groups. (1) Liquid handling: pipettes, a pipette controller and bottle-top dispensers. (2) Mixing and heating: magnetic hotplate stirrers, a vortex mixer and, where needed, an overhead stirrer or homogenizer. (3) Separation: a microcentrifuge and, for solvent work, a rotary evaporator with a vacuum source. (4) Measurement: a pH/conductivity meter and a UV-Vis spectrophotometer. (5) Temperature control: dry baths, a chiller or cooling block. Molecular biology labs add a thermal cycler, electrophoresis and gel imaging. Buy the instrument that limits your daily workflow first; the rest can follow as throughput grows.

    Research lab bench with pipettes, a magnetic hotplate stirrer with a beaker, a microcentrifuge and a benchtop pH meter arranged left to right
    Organize the equipment list by the path a sample takes across the bench: measure, mix and heat, separate, measure again, hold temperature.

    1.  Plan Before You Buy: Map the Workflow

    Equipment chosen one item at a time often leaves gaps: a hotplate with no way to monitor the solution temperature, or a centrifuge whose rotor does not take the tubes the lab actually uses. A short planning exercise before you write a lab startup equipment request avoids most of these mismatches.

    Map the sample path

    Write down your three to five most frequent procedures as a sequence of steps. For each step, note the volume handled, the temperature range, the solvents or reagents involved and how many samples move through it per day. A typical materials chemistry synthesis, for example, might read: dispense precursor solution, stir and heat to reflux, cool, centrifuge to collect particles, redisperse, measure absorbance. Each verb maps to a class of equipment, and the numbers attached to it (volume, temperature, sample count) map to the specifications you need.

    Step in the sample path Equipment class Specifications that usually decide the choice
    Measure and transfer liquids Pipettes, dispensers, burettes Volume range, number of channels, chemical compatibility, autoclavability
    Mix, heat and disperse Hotplate stirrers, overhead stirrers, homogenizers, vortex mixers, shakers Plate size and material, maximum temperature, speed range, stirring volume, viscosity limit
    Separate Centrifuges, rotary evaporators, vacuum pumps Maximum RCF (×g), rotor and tube formats, refrigeration, flask size, vacuum level
    Measure UV-Vis spectrophotometers, pH/conductivity/DO meters Wavelength range, bandwidth, measurement parameters, calibration and temperature compensation
    Hold temperature Dry baths, thermo mixers, cooling blocks, chillers Temperature range, stability, block formats, cooling capacity

    Size by throughput, not by aspiration

    A lab that runs ten samples a week has different needs from one that runs a hundred a day. Throughput affects three choices more than any others:

    • Channels and formats. If plates or tube strips are routine, a multichannel pipette and a microcentrifuge rotor or spin-down unit that accepts strips will save more time than a faster single-channel instrument.
    • Positions. Parallel reactions favor a multi-position stirrer over several single hotplates sharing a bench.
    • Duty cycle. Instruments that run all day, such as a chiller feeding a condenser, should be specified for continuous use at the temperatures you actually need.

    Buy the bottleneck first

    When you cannot equip everything at once, rank each item by how often a missing or shared instrument stops work. A shared pipette set or a single hotplate becomes a queue within a week; a second spectrophotometer rarely does. Items that are used by every person every day belong at the top of the list. Items used for one technique a month can usually be shared with a neighboring lab or added later. The checklists in Section 8 follow this logic.

    Write the safety plan alongside the list

    Equipment decisions and safety decisions are linked. In the United States, the OSHA Laboratory Standard requires that "where hazardous chemicals as defined by this standard are used in the workplace, the employer shall develop and carry out the provisions of a written Chemical Hygiene Plan" [1]. That plan must include "a requirement that fume hoods and other protective equipment are functioning properly and specific measures that shall be taken to ensure proper and adequate performance of such equipment" [1]. Planning ventilation, electrical circuits and waste handling together with the equipment list is easier than retrofitting them later. Prudent Practices in the Laboratory from the National Research Council is a widely used reference for this planning [2]. Biological work should also be planned around a protocol-specific risk assessment, which the CDC/NIH BMBL describes as its "core principle" [3].

    2.  Liquid Handling: Pipettes, Dispensers and Burettes

    Almost every procedure starts with moving a measured volume of liquid, so liquid handling is usually the first purchase and the one most often under-specified. Volume errors carry through every downstream step.

    Pipettes

    Air-displacement piston pipettes cover the microliter range and are the default tool for aqueous solutions. Requirements and test methods for piston pipettes are set out in ISO 8655-2, and the gravimetric reference procedure used to check them is described in ISO 8655-6 [4][7]. When building a pipette set, consider:

    • Volume coverage. A set of three or four single-channel pipettes typically covers 0.5 µL to 1000 µL, with a larger-volume pipette added for 1–10 mL transfers. Pipette performance varies by model and set volume. Check the manufacturer's accuracy and precision specifications at the volumes you expect to dispense; overlapping ranges can help you choose a suitable pipette for each task.
    • Mechanical or electronic. Mechanical pipettes are simple and robust. Electronic pipettes add motor-driven aspiration and programmed modes (such as repeat dispensing or mixing), which reduce variation between users and hand strain during long runs.
    • Autoclavability. Molecular and cell biology labs often need pipettes whose lower section, or the whole body, can be autoclaved.

    ALab™ options include the Toppette mechanical pipette, offered in single-channel, 8-channel, 12-channel and fixed-volume versions; its single-channel models cover 0.1 µL to 10000 µL across 13 ranges, and its lower section is autoclavable. The MicroPette Plus is fully autoclavable at 121 °C. For electronic pipetting, the dPette and dPette+ cover 0.5 µL to 1000 µL in single-channel models, and the dPette+ single-channel adds pipetting, mixing, stepper and dilution modes. The full range is on the pipettes category page.

    Pipette controllers

    Serological pipettes in the 1–100 mL range need a pipette controller. Look for speed control, a replaceable hydrophobic filter that protects the instrument from liquid ingress, and a rechargeable battery. The Levo Plus pipette controller works with serological pipettes from 0.1 mL to 100 mL, has six speeds and uses a 0.45 µm hydrophobic filter.

    Bottle-top dispensers and burettes

    Repeated dispensing of the same reagent, such as a solvent, an acid or a buffer, is faster and cleaner from a bottle-top dispenser than from a graduated cylinder. ISO 8655-5 covers dispensers, and ISO 8655-3 covers piston burettes [5][6]. The main selection factor is chemical compatibility of the wetted parts with your reagents.

    Need What to look for ALab™ example
    General reagents, 0.5–100 mL Several volume ranges, autoclavable, reagent recovery DispensMate-Pro: 0.5–100 mL in five ranges; fully autoclavable at 121 °C
    Hydrofluoric acid Wetted parts resistant to HF (glass is attacked) DispensMate-HF: 1.0–10 mL; ceramic piston, cylinder and valve; FEP tubes
    Electronic, programmable dispensing Motor drive, speed settings, stepper mode dFlow: 0.1–99.9 mL; 16 speeds; continuous or stepper mode
    Titration Fine resolution, integrated stirring dTrite electronic burette: 0.01–99.99 mL; 10 µL resolution; built-in magnetic stirrer
    Repetitive small aliquots Positive displacement, many steps per fill StepMate: 10 µL–5 mL per step; up to 48 steps per filling

    HF requires dedicated training, PPE and emergency procedures well beyond dispenser choice; consult the SDS and the NIOSH Pocket Guide entry before any HF work [20]. See all models on the bottle-top dispensers page.

    Liquid waste aspiration

    Cell culture and molecular biology workflows may generate liquid waste that can be collected with a vacuum aspiration system configured for the waste and its hazards. Appropriate collection traps, filters, decontamination and handling procedures should follow the laboratory's risk assessment and applicable biosafety requirements. The SafeVac vacuum-controlled aspiration system has a 0–600 mbar vacuum range, a 4 L collection bottle and level detection to prevent overfilling. Related units are on the vacuum aspirators page.

    3.  Stirring, Heating and Dispersing

    The second stage of most sample paths is mixing, often with heat. The right instrument depends on volume, viscosity and the temperature the chemistry needs.

    Magnetic hotplate stirrers

    A magnetic hotplate stirrer is a common choice for chemistry benches where solutions need to be mixed and heated. When comparing models, focus on:

    • Plate material. Glass-ceramic plates tolerate high temperatures and many chemicals. Coated metal plates spread heat quickly and evenly over a smaller area.
    • Maximum temperature and control. Check whether the instrument accepts an external temperature sensor placed in the liquid. Controlling to the solution temperature, rather than the plate temperature, gives more repeatable results.
    • Safety features. Independent overheat protection and a residual-heat warning are worth checking on every model.
    • Stirring volume. Manufacturers usually quote this for water; viscous mixtures stir less effectively.
    Model Plate Temperature range Speed Notes from the product page
    MS-H-Pro+ 5-inch (Ø135 mm) ceramic-coated stainless steel RT to 340 °C 100–1500 rpm 20 L (H2O) stirring volume; PT1000 external sensor; overheat protection at 420 °C; "HOT" warning above 50 °C
    MS7-H550-Pro 7-inch (184 × 184 mm) glass-ceramic RT to 550 °C 100–1500 rpm 20 L stirring volume; PT1000 sensor; overheat protection at 580 °C
    MS-H-S10 10 positions on a 180 × 450 mm plate RT to 120 °C 0–1100 rpm 0.4 L per position; parallel reactions and screening
    MS-H280-B / F series Heating mantle with stirring RT to 280 °C 200–1500 rpm 100–1000 mL flat-bottom beakers (B) or round-bottom flasks (F); PT1000 sensor

    For heating without stirring, the DHP7-550 hotplate has a 7-inch glass-ceramic plate, reaches 550 °C and offers three heating modes. For stirring at room temperature, the non-heating MS-S magnetic stirrer stirs up to 20 L. The magnetic stirrers and hotplates category pages list the full ranges.

    Overhead stirrers

    Magnetic coupling weakens as viscosity rises. Polymer solutions, slurries and pastes, or volumes beyond what a stir bar can move, need an overhead stirrer that drives a shaft and impeller directly. The key specifications are maximum viscosity, maximum torque and stirring volume. In the OS-Pro series, the OS20-Pro, OS40-Pro and OS70-Pro are rated for 20, 40 and 70 L, with maximum viscosities of 10000, 50000 and 100000 mPa·s. Each displays speed and torque, which helps track viscosity changes during a reaction. More options are on the overhead stirrers page.

    Homogenizers and dispersers

    Breaking up agglomerates, making emulsions or dispersing nanoparticles in a liquid calls for high shear. A rotor–stator homogenizer forces the sample through a narrow gap at high speed. The D-500 high-shear homogenizer runs at 10000–30000 rpm and handles working volumes from 10 mL to 40000 mL, depending on the dispersing head. For small samples, the D-160 handheld homogenizer covers 0.1–250 mL at 8000–32000 rpm. See the homogenizers page.

    Vortex mixers, rollers and shakers

    Tube-scale mixing is usually handled by a vortex mixer, a tube roller or a shaker:

    • Vortex mixer. Resuspends pellets and mixes small tubes in seconds. The MX-S vortex mixer runs at 0–3000 rpm with touch or continuous operation.
    • Tube roller. Gives gentle, continuous mixing for viscous reagents or particle suspensions that should not foam. The MX-T6-S tube roller has six rollers turning at 0–70 rpm.
    • Orbital shaker. Agitates flasks, plates or staining trays for long periods. The SK-O series orbital shakers include five models, with timers from 1 minute to 99 h 59 min.

    The mixers category page groups vortex mixers, rollers and shakers.

    4.  Separation: Centrifuges and Rotary Evaporators

    After mixing and reaction, most samples need something removed: a solid from a liquid, or a solvent from a product.

    Centrifuges

    The most important centrifuge specification is relative centrifugal force (RCF, expressed as ×g), not rpm. RCF depends on both rotor speed and rotor radius, so two instruments with the same rpm can deliver different forces. Protocols should specify ×g; check that the instrument and rotor reach it. Next, match the rotor to your tubes: 0.2 mL PCR tubes and strips, 1.5/2 mL microtubes, 15/50 mL conical tubes or larger bottles. Refrigeration matters for temperature-sensitive biological samples. Centrifuge safety, including balancing loads and inspecting rotors, is covered in Prudent Practices [2].

    Use ALab™ example Published figures
    Quick spin-down of tubes and strips D1008 palm micro-centrifuge 7000 rpm, 2680 ×g; 8 × 0.2–2 mL tubes or PCR strips
    Routine microtube work D3024 high-speed micro-centrifuge 15000 rpm, 21380 ×g; 24 × 1.5/2 mL rotor; dual door interlock
    Temperature-sensitive microtube work D1524R refrigerated micro-centrifuge 15000 rpm, 21380 ×g; −20 to 40 °C; pre-cools to 4 °C in 7 min
    Larger volumes, particle collection DG1616 / DG1616R high-speed centrifuges 16000 rpm, 28621 ×g; up to 4 × 400 mL; R model −10 to 40 °C

    The centrifuge category page lists every model and rotor.

    Rotary evaporators and vacuum

    For labs that regularly remove solvent from heat-sensitive samples or recover solvent, a rotary evaporator may be useful. Whether it is appropriate depends on the solvent, sample sensitivity, batch size, throughput and available alternatives. A rotary evaporator lowers the boiling point under vacuum, spreads the liquid as a thin film on a rotating flask and condenses the vapor for recovery. Our complete guide to rotary evaporation covers principles, setup and solvent recovery in depth. Shorter explainers cover how a rotary evaporator works in five steps, why the flask rotates, solvent boiling points under vacuum and rotary evaporation versus simple distillation.

    A complete rotary evaporation station has four parts. Each should be planned together:

    Component Role ALab™ example
    Rotary evaporator Rotates the flask in a heated bath and condenses vapor RE100-Pro: 50–3000 mL flasks; 20–280 rpm; bath RT to 180 °C; motorized 150 mm lift
    Vacuum source Lowers the boiling point C410 diaphragm vacuum pump: oil-free; 13 mbar ultimate vacuum; 25 L/min free air
    Vacuum controller Holds a set pressure to limit bumping and improve recovery VC100 vacuum controller: 1–1000 mbar; 5 programs × 5 steps
    Condenser cooling Removes heat from the condenser DCP-5 recirculating chiller: −20 to 40 °C; ±0.3 °C; 700 W cooling capacity at 20 °C

    Where bench space or a chiller loop is a constraint, the RE100-CV combines a self-cooling condenser (room temperature to −40 °C) with a built-in vacuum controller (1–1000 mbar). The rotary evaporator category page lists the rest of the range. Flammable solvent work also triggers ventilation and fire-protection requirements; see NFPA 45 and your institution's chemical hygiene plan [14][1].

    5.  Measurement: UV-Vis and Electrochemistry Meters

    Measurement instruments turn a sample into data. Two classes appear on most research lab equipment lists.

    UV-Vis spectrophotometers

    UV-Vis spectrophotometry is used to determine concentrations, follow reaction kinetics, check nanoparticle formation and assess nucleic acid or protein samples. Quantitative work relies on the Beer–Lambert law, which relates absorbance to concentration and optical path length [9]. Specifications that matter:

    • Wavelength range. Visible-range instruments typically start around 320 nm. Work in the ultraviolet (for example, nucleic acids at 260 nm) needs a UV-capable instrument with quartz cuvettes.
    • Spectral bandwidth. Narrower bandwidth resolves sharp absorption features more faithfully.
    • Single or double beam. A double-beam design compares sample and reference signals during a measurement, which can help compensate for changes in the light source and improve measurement stability during long scans or kinetic measurements.

    The SP-1000/1100 series includes four single-beam models (SP-V1000, SP-UV1000, SP-V1100 and SP-UV1100); the SP-UV1100 covers 190–1100 nm, and bandwidths of 4.0 nm or 2.0 nm are available. The double-beam SP-UV3101 covers 190–1100 nm with 1.0 nm bandwidth and a 10.1-inch touchscreen. See the spectrophotometers page.

    pH, conductivity and dissolved oxygen meters

    pH is the most common measurement in chemistry and biology alike, and buffer preparation alone justifies a dedicated meter. The IUPAC recommendations on pH measurement define the procedures and standard buffers that make pH values traceable [8]. Conductivity is used to check water purity and electrolyte concentration (ISO 7888 describes a standard water-quality method [11]). Dissolved oxygen (DO) matters in environmental, electrochemical and fermentation work (ISO 17289 covers the optical sensor method [10]).

    Choose the form factor by where the measurement happens:

    Form factor Best for ALab™ example
    Benchtop meter Daily buffer preparation, multi-point calibration, data logging at a fixed station Benchtop Meters, Classical Series: seven pH/conductivity/DO models; 7-inch display; automatic calibration; automatic temperature compensation
    Portable meter Measurements at several benches, in a fume hood or in the field Portable Meters: eight models; 3.5-inch TFT display; IP57; for example the DPCD10 for pH, conductivity and DO
    Pocket tester Quick checks, teaching labs, spot measurements Pocket Testers: eight models; IP67; replaceable probes

    IP ratings are defined in IEC 60529 and describe protection against solids and water ingress [13]. All meters are listed on the electrochemistry meters page.

    6.  Temperature Control: Dry Baths, Thermo Mixers and Chillers

    Many steps need a sample held at a set temperature: enzyme incubation, denaturation, sample storage during handling, or cooling a condenser. The right tool depends on format and range.

    • Dry baths hold tubes in aluminum blocks with no water, which avoids contamination and evaporation issues. The H100-Pro dry bath covers room temperature +5 °C to 100 °C with ±0.5 °C accuracy, uses magnetic heat blocks and supports six-step programs. The low-profile HB120-S / HB120-SC / HB60-S series offers fixed-temperature and adjustable options up to 120 °C.
    • Thermo mixers combine temperature control with orbital mixing, useful for enzymatic reactions and lysis. The HCM100-Pro / HM100-Pro mixes at 200–1500 rpm with a 3 mm orbit. For the HCM100-Pro's cooling range, consult the live product page.
    • Cooling blocks replace ice buckets for keeping enzymes and samples cold during setup. The CT4-Pro cooling thermo block holds 4 °C with ±0.5 °C accuracy and reaches 4 °C in 10 minutes or less.
    • Recirculating chillers cool condensers, reactor jackets and other equipment. The DCP-5 covers −20 to 40 °C with ±0.3 °C stability and a 4.5 L tank; its published cooling capacity is 700 W at 20 °C. Cooling capacity falls as the setpoint drops, so check the manufacturer's figures for your working temperature rather than estimating them.

    The dry baths and thermal control page lists the full range.

    7.  The Molecular Biology Bench

    Molecular biology labs build on the same liquid handling, centrifugation and temperature-control core, then add instruments for nucleic acid work. Everything in this section is described for research use only. Biosafety requirements depend on the organisms and materials involved and should follow a protocol-specific risk assessment as described in the BMBL [3].

    Thermal cyclers and real-time PCR

    A thermal cycler is the central instrument of a PCR workflow. Compare block format (96-well is standard), ramp rate, temperature range and whether a gradient function is available for optimizing annealing temperatures. The TC1000-G-Pro and TC1000-S+ are 96-well Peltier cyclers with a 0–105 °C block range and up to 5 °C/s ramping; the TC1000-G-Pro adds a 30–105 °C gradient. For quantitative PCR, the Accurate 96 real-time PCR system offers 4 or 6 fluorescence channels and up to 6.0 °C/s ramping. When reporting qPCR results, the MIQE guidelines describe the minimum information that should accompany published experiments [17]. See the PCR thermal cyclers page.

    Electrophoresis and gel imaging

    Agarose gel electrophoresis separates DNA fragments by size and remains a routine check after PCR and digestion [18]. A basic setup includes a tank, a power supply and a way to visualize the gel.

    Item ALab™ example Published figures
    Horizontal (agarose) tank DL-SUB01 60 × 75 mm gel; 300 mL buffer
    Vertical (polyacrylamide) tank DL-Mini01 Two 8.3 × 7.3 cm gels
    Wet transfer tank DL-ZY02 110 × 90 mm transfer area
    Power supply DEP-300 / DEP-600 / DEP-300HC Constant voltage, current or power; 0–300 V or 0–600 V
    Gel visualization TI470 blue light transilluminator 470 nm blue LED with amber filter, for compatible nucleic acid stains

    Blue-light transillumination with a compatible stain avoids working over a UV source. UV exposure limits for skin and eyes are set out in ICNIRP guidelines [19]; if a lab does use UV transilluminators, plan face and eye protection accordingly. See the electrophoresis and gel imaging and transilluminators pages.

    Nucleic acid extraction

    Labs that process many samples may automate extraction. The MNE-96-03 automated nucleic acid extraction system uses magnetic beads to process 1–96 samples at 50–1000 µL. Smaller labs often begin with manual column or bead kits and a microcentrifuge, and add automation once sample numbers justify it.

    8.  Lab Equipment Checklists by Lab Type

    The four checklists below are editorial suggestions from ACS Material to help you plan. They are not standards, regulations or a complete inventory. Your institution's safety office, chemical hygiene plan and biosafety review determine what is required [1][3]. Priorities:

    • Essential: needed from the first day of routine work.
    • Common: found in most labs of this type; add within the first months.
    • Can wait: useful once throughput or methods grow; often shared at first.

    Items without a link are general lab infrastructure or categories outside this guide.

    Materials chemistry lab (synthesis of nanomaterials, coatings, functional materials)

    Much materials science lab equipment overlaps with the synthetic chemistry list; the difference is a stronger emphasis on dispersion, particle collection and optical characterization.

    Item Priority Why it is on the list Example
    Fume hood or other local exhaust Essential Solvent and precursor handling Facility infrastructure
    Analytical balance Essential Weighing precursors —
    Single-channel pipette set (0.5–1000 µL) plus 1–10 mL Essential Precursor and reagent transfer Toppette
    Bottle-top dispenser for solvents Common Repeated solvent dispensing DispensMate-Pro
    Magnetic hotplate stirrer with external sensor Essential Heated synthesis at controlled solution temperature MS7-H550-Pro
    Multi-position stirrer Can wait Parallel screening MS-H-S10
    High-shear homogenizer Common Dispersing particles, emulsions D-500
    Overhead stirrer Can wait Viscous slurries and polymer solutions OS-Pro series
    High-speed centrifuge Essential Collecting and washing particles DG1616
    Vortex mixer Common Redispersing pellets MX-S
    Rotary evaporator with vacuum pump Common Solvent removal and recovery RE100-Pro + C410
    UV-Vis spectrophotometer Common Optical characterization, concentration SP-UV3101
    pH meter Essential Precursor solutions and pH-controlled growth Benchtop Meters
    Drying oven and furnace Common Drying and annealing —

    Synthetic chemistry lab (organic and inorganic synthesis)

    Item Priority Why it is on the list Example
    Fume hoods sized for the number of chemists Essential Primary engineering control for volatile chemicals Facility infrastructure
    Analytical and top-loading balances Essential Weighing reagents and products —
    Magnetic hotplate stirrers, one per chemist Essential Most reactions are stirred and heated MS-H-Pro+
    Heating mantles with stirring for round-bottom flasks Common Reflux with even heating MS-H280-B / F series
    Rotary evaporator Essential Workup and solvent removal RE100-Pro
    Oil-free vacuum pump Essential Rotary evaporation, filtration C410
    Vacuum controller Common Reproducible evaporation, less bumping VC100
    Recirculating chiller Common Condenser cooling without tap water DCP-5
    Bottle-top dispensers for common solvents Common Safer repeated dispensing dFlow
    Electronic burette Can wait Titrations and standardization dTrite
    Overhead stirrer Can wait Scale-up, viscous mixtures OS-Pro series
    Benchtop centrifuge Common Separating precipitates D3024
    Flammables storage cabinet Essential Solvent storage per fire code —
    Glassware, Schlenk line or inert gas manifold Common Air-sensitive chemistry —

    Molecular biology lab (research use only)

    Item Priority Why it is on the list Example
    Biosafety cabinet, as required by risk assessment Essential Containment for biological materials Facility infrastructure
    Single- and multichannel pipettes, autoclavable Essential All reaction setup MicroPette Plus
    Electronic pipette Common Long plate setups, repeat dispensing dPette+
    Pipette controller Essential Serological pipettes for media and buffers Levo Plus
    Refrigerated microcentrifuge Essential Extractions and cold spins D1524R
    Palm spin-down centrifuge Common Collecting liquid in tubes and strips D1008
    Vortex mixer Essential Mixing and resuspension MX-S
    Dry bath Essential Incubation and denaturation H100-Pro
    Thermo mixer Common Heated mixing for enzymatic steps HCM100-Pro
    Cooling block Common Keeping enzymes cold during setup CT4-Pro
    Thermal cycler Essential PCR TC1000 series
    Electrophoresis tank and power supply Essential Checking PCR products and digests DL-SUB01 + DEP series
    Gel visualization Essential Reading gels TI470
    Real-time PCR system Can wait Quantitative assays Accurate 96
    Aspiration system for liquid waste Common Safer liquid waste collection SafeVac

    Teaching lab (undergraduate chemistry and general science)

    Item Priority Why it is on the list Example
    Eyewash and safety shower within reach Essential Emergency response Facility infrastructure
    Fume hoods for demonstration and volatile work Essential Exposure control Facility infrastructure
    Mechanical pipettes, one set per bench group Essential Measurement technique training Toppette
    Bottle-top dispensers at the reagent station Common Faster, cleaner reagent distribution DispensMate-Pro
    Magnetic stirrers (non-heating) Essential Dissolution, titration MS-S
    Magnetic hotplate stirrers with overheat protection Essential Heated experiments MS-H-Pro+
    Pocket pH testers Essential One per student pair Pocket Testers
    Benchtop pH/conductivity meter Common Instructor reference, buffer preparation Benchtop Meters
    Visible spectrophotometer Common Beer–Lambert experiments SP-1000/1100 series
    Electronic burette Can wait Titration demonstrations dTrite
    Vortex mixer Common Mixing small samples MX-S
    Small benchtop centrifuge Can wait Precipitate separation exercises D3024
    Top-loading balances Essential Weighing —

    9.  Shared Utilities: What Sets the Grade of Equipment You Need

    Utilities and building conditions often decide which version of an instrument a lab can run. Check these before finalizing the list.

    Bench space and layout

    Measure usable bench depth and width, not just the instrument footprint. Rotary evaporators need clearance for the lift and the flask; centrifuges need clearance around the lid and a stable surface; hotplates need distance from flammable materials and from instruments sensitive to heat. Place the instruments in the order the sample travels, so samples move along the bench rather than back and forth across the room.

    Electrical supply

    Heating instruments, centrifuges and chillers draw the most power. Check the rating published on each product page, for example 550 W for the MS-H-Pro+, 1050 W for the MS7-H550-Pro or 500 W for the D-500. Then ask your facilities team how circuits are distributed along each bench. Avoid daisy-chained power strips for heating equipment. Laboratory electrical equipment is designed and tested against IEC 61010-1 [12]; confirm voltage and plug type for your region before ordering.

    Ventilation

    Ventilation is a building system, not a benchtop purchase, but it shapes the equipment list. The number of fume hoods limits how many chemists can run volatile reactions or rotary evaporation at once. Laboratory ventilation is addressed in ANSI/ASSP Z9.5, fume hood performance testing in ANSI/ASHRAE 110 and fire protection for chemical laboratories in NFPA 45 [15][16][14]. Under the OSHA Laboratory Standard, the chemical hygiene plan must address the proper function of fume hoods [1].

    Chemical resistance

    Check what your reagents touch. Wetted parts on dispensers and vacuum components, plate coatings on hotplates and the housing of benchtop instruments all have chemical-resistance limits. For example, the VC100 lists PTFE, PP, silicone and ceramics as its vapor-contact materials, and the DispensMate-HF uses ceramic and FEP for hydrofluoric acid. When a chemical is not listed, ask before you buy.

    Water, emergency equipment and waste

    Plan purified water supply, eyewash and safety shower locations (ANSI/ISEA Z358.1 is the common US reference [21]), and separate waste streams for solvents, aqueous waste and biological waste. These decisions affect where equipment can go.

    10.  Frequently Asked Questions

    What basic laboratory equipment does every new research lab need?

    Most new labs need calibrated pipettes, a magnetic hotplate stirrer, a vortex mixer, a centrifuge suited to their tube formats, a pH meter and an analytical balance, plus the fume hood and safety equipment set by their chemical hygiene plan. The rest depends on the lab type; see the checklists in Section 8.

    How should I prioritize a new lab setup checklist?

    Rank equipment by how often a missing or shared instrument stops daily work. Items everyone uses every day come first. Items used for one technique occasionally can be shared or added later. Our checklists mark each item Essential, Common or Can wait as an editorial starting point.

    What is the difference between a chemistry lab equipment list and a molecular biology list?

    Both share liquid handling, mixing, centrifugation and temperature control. Chemistry labs add fume hoods, rotary evaporation, vacuum pumps and higher-temperature heating. Molecular biology labs add autoclavable pipettes, refrigerated microcentrifuges, thermal cyclers, electrophoresis and gel imaging, and follow a biosafety risk assessment.

    Should I specify centrifuges by rpm or by ×g?

    By ×g (relative centrifugal force). RCF depends on both speed and rotor radius, so rpm alone does not describe the force on the sample. Write protocols in ×g and confirm that the instrument and rotor reach it.

    Do I need a rotary evaporator in a new lab?

    If your lab regularly removes solvent from heat-sensitive samples or recovers solvent, a rotary evaporator may be useful. Whether it is appropriate depends on the solvent, sample sensitivity, batch size, throughput and available alternatives. Our rotary evaporation guide explains how to size and set up a station.

    Are these checklists a safety standard?

    No. They are editorial suggestions to help with planning. Requirements come from regulations, your institution's chemical hygiene plan and biosafety review, and the manufacturer's instructions for each instrument.

    11.  Keep Exploring the Lab Essentials Hub

    Browse all ALab™ Lab Essentials.

    12.  References

    1U.S. Occupational Safety and Health Administration. 29 CFR 1910.1450, Occupational exposure to hazardous chemicals in laboratories. https://www.osha.gov/laws-regs/regulations/standardnumber/1910/1910.1450
    2National Research Council. Prudent Practices in the Laboratory: Handling and Management of Chemical Hazards, updated version. Washington, DC: The National Academies Press; 2011. https://doi.org/10.17226/12654
    3Centers for Disease Control and Prevention; National Institutes of Health. Biosafety in Microbiological and Biomedical Laboratories, 6th edition. 2020. https://www.cdc.gov/labs/bmbl/index.html
    4ISO 8655-2:2022. Piston-operated volumetric apparatus — Part 2: Pipettes. International Organization for Standardization.
    5ISO 8655-5:2022. Piston-operated volumetric apparatus — Part 5: Dispensers. International Organization for Standardization.
    6ISO 8655-3:2022. Piston-operated volumetric apparatus — Part 3: Burettes. International Organization for Standardization.
    7ISO 8655-6:2022. Piston-operated volumetric apparatus — Part 6: Gravimetric reference measurement procedure for the determination of volume. International Organization for Standardization.
    8Buck RP, Rondinini S, Covington AK, et al. Measurement of pH. Definition, standards, and procedures (IUPAC Recommendations 2002). Pure and Applied Chemistry. 2002;74(11):2169–2200. https://doi.org/10.1351/pac200274112169
    9IUPAC. Beer–Lambert law. In: Compendium of Chemical Terminology (the "Gold Book"). https://doi.org/10.1351/goldbook.B00626
    10ISO 17289:2014. Water quality — Determination of dissolved oxygen — Optical sensor method. International Organization for Standardization.
    11ISO 7888:1985. Water quality — Determination of electrical conductivity. International Organization for Standardization.
    12IEC 61010-1:2010+AMD1:2016. Safety requirements for electrical equipment for measurement, control, and laboratory use — Part 1: General requirements. International Electrotechnical Commission.
    13IEC 60529. Degrees of protection provided by enclosures (IP Code). International Electrotechnical Commission.
    14NFPA 45. Standard on Fire Protection for Laboratories Using Chemicals. National Fire Protection Association.
    15ANSI/ASSP Z9.5-2022. Laboratory Ventilation. American Society of Safety Professionals.
    16ANSI/ASHRAE 110-2016. Methods of Testing Performance of Laboratory Fume Hoods. ASHRAE.
    17Bustin SA, Benes V, Garson JA, et al. The MIQE guidelines: minimum information for publication of quantitative real-time PCR experiments. Clinical Chemistry. 2009;55(4):611–622. https://doi.org/10.1373/clinchem.2008.112797
    18Lee PY, Costumbrado J, Hsu CY, Kim YH. Agarose gel electrophoresis for the separation of DNA fragments. Journal of Visualized Experiments. 2012;(62):e3923. https://doi.org/10.3791/3923
    19International Commission on Non-Ionizing Radiation Protection. Guidelines on limits of exposure to ultraviolet radiation of wavelengths between 180 nm and 400 nm (incoherent optical radiation). Health Physics. 2004;87(2):171–186. https://doi.org/10.1097/00004032-200408000-00006
    20National Institute for Occupational Safety and Health. NIOSH Pocket Guide to Chemical Hazards: Hydrogen fluoride. https://www.cdc.gov/niosh/npg/npgd0334.html
    21ANSI/ISEA Z358.1-2014 (R2020). American National Standard for Emergency Eyewash and Shower Equipment. International Safety Equipment Association.
    ALab™ is a trademark of ACS Material, LLC. Disclaimer: This article is for general information about laboratory equipment planning. The checklists are editorial suggestions, not standards or regulatory requirements. Always follow applicable regulations, your institution's safety and biosafety requirements, and the operating instructions for each instrument. Specifications are summarized from ACS Material product pages at the time of writing; check the product page for current details. Products described are for research use only and are not intended for clinical or diagnostic use.